iBoot-PDU_v170515e
iBoot-PDU User Manual
Page 70
iBoot-PDU4-C10
C14
4 x C13
iBoot-PDU8-C10
C14
8 x C13
iBoot-PDU8-2C10
2 x C14
8 x C13
iBoot-PDU4-C20
C20
4 x C13
iBoot-PDU8-C20
C20
8 x C13
iBoot-PDU8-2C20
2 x C20
8 x C13
Key:
Input:
N15
NEMA 5-15 Linecord 115VAC 15 Amps combined total switched
N20
NEMA 5-20 Linecord 115VAC 20 Amps combined total switched
C14
IEC320 C14 Receptacle 100-240VAC 10 Amps total at 240VAC Max
C20
IEC320 C20 Receptacle 100-240VAC 20 Amps total at 240VAC Max
Outlet:
N15
NEMA 5-15 Receptacle 115VAC 12 Amps Max
C13
IEC 320 C13 Receptacle 100-240VAC 10 Amps Max
12.4. Safety
Comply with UL60950-1, 2nd Edition 2014-10-14 (US)
Comply with CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Canada)
12.5. Emissions
ANSI C63.4:2014 & 47 CFR Part 15, Subpart B, Class B
ICES-003:2016 Issue 6, Class B
12.6. Environmental
RoHS2 Directive 2011/65/EU Compliant
Rated Pollution Degree 2 (PD 2) for use in business/laboratory environments with only Non-Conductive
pollution present