TECHNICAL SPECIFICATIONS
28
VLASE™ IR
Table 5: Command Box connector pinout
* refers to Lighter user's manual "Setting I/O parameters" paragraph to set the signal properties
** refers to Lighter user's manual
*** ** see "
Input/Output specifications" on page 34
14
RESERVED
Digital Input
DO NOT CONNECT
15
RESERVED
Digital Input
DO NOT CONNECT
16
RESERVED
Digital Input
DO NOT CONNECT
17
END
Digital Output
This signal is used to know if the marking
process is finished:
- ON at the end of marking process
18
POWER_ON
Digital Output
This signal is used to know if the system is
already warmed up:
- ON when the laser is in STAND_BY or
READY state
19
GND
Ground
Ground reference
20
SYSTEM_ALARM
Digital Output
This signal is used to know if the system is in
booting up state or in error state:
- ON during BOOTING UP
- ON in case of system error
21
GND
Ground
Ground reference
22
ENABLE_OUT
Digital Output
This signal is used to know if the system is
ready to emit laser radiation:
- ON when the system is in READY state
23
SW_READY*
Digital Output
This signal is used to know if a document,
sequence or script is loaded and ready to be
executed:
- ON when a document or a sequence is run-
ning in AUTO MODE** or WORK MODE**
(SW_READY COMPATIBILITY** = true)
- ON when a document or a sequence is run-
ning in AUTO MODE** and laser in READY
state (SW_READY COMPATIBILITY** = false)
- ON when a script is running n AUTO
MODE** and "IoPort.setReady (true)" func-
tion is used
24
GND
Ground
Ground reference
25
GND
Ground
Ground reference
PIN
SIGNAL
TYPE***
DESCRIPTION
Содержание VLASE IR 1109-1 42 Series
Страница 1: ...VLASE IR USER MANUAL InfraRed Laser Marker ...
Страница 72: ...USE AND OPERATION 64 VLASE IR ...
Страница 98: ...LABELS 90 VLASE IR Positioning of labels on the resonator Figure 2 External labels rsonator location ...
Страница 101: ...PERFORMANCE LEVEL PL USER MANUAL 93 BLOCK DIAGRAM ...
Страница 121: ...THERMALIZATION AND SUPPRESSION OF GIANT PULSES USER MANUAL 113 ...
Страница 133: ...USER MANUAL 125 APPENDIX G MECHANICAL DRAWINGS ...
Страница 134: ...MECHANICAL DRAWINGS 126 VLASE IR CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings ...
Страница 135: ...RESONATOR USER MANUAL 127 RESONATOR NOTE Please refer to Datalogic website for detailed drawings ...