RESONATOR INSTALLATION
USER MANUAL
13
RESONATOR INSTALLATION
The resonator can be installed in any orientation and must be fixed to a suitable base
(not supplied by Datalogic) using the dedicated threaded holes.
4x Fixing holes M6X1
2x Reference holes Ø6H7
Beam Exit
NOTE
Figure 6: Resonator fixing points
Rsonator mounting screws length
To determine the length of the mounting screws, consider the thickness of the mount-
ing plate and the thickness of the washer.
control rack
10 mm
Washer thickness
Mounting plate thickness
M6 screw
Figure 7: Length of mounting screws.
All dimensions are in millimeters.
NOTE
Mounting holes depth is = 10mm. Tightening torque = 2 Nm.