CONNECTORS SPECIFICATIONS
USER MANUAL
23
CONNECTORS SPECIFICATIONS
Interlock
Disables the Class4 laser source inside the laser marker. Interlock internal circuit is
designed to comply with the single fault condition.
Control Rack back panel connector
Type SWITCHCRAFT TB Series male Tini Q-G (Mini XLR) panel mount connector, 4 pins.
VCC_INT_IN_A
OUTPUT
24V DC reference for INTERLOCK_A signal
INTERLOCK_A
INPUT
INTERLOCK IN signal A
GND_INT_IN_B
GND
Ground reference for INTERLOCK_B signal
INTERLOCK_B
INPUT
INTERLOCK IN signal B
Figure 4: Interlock connector, male panel plug (front view)
Table 1: Interlock connector pinout
Electric Diagram
Figure 5: Interlock connector electric diagram
Table 2: Interlock connector conditions
PIN
SIGNAL
TYPE
DESCRIPTION
1
2
3
4
PIN1-PIN2
PIN3-PIN4
MARKING
FUNCTIONALITY
CONDITION
CONTACT OPEN
CONTACT OPEN
NOT POSSIBLE
SAFE
CONTACT CLOSED
CONTACT OPEN
NOT POSSIBLE
DANGEROUS
CONTACT OPEN
CONTACT CLOSED
NOT POSSIBLE
DANGEROUS
CONTACT CLOSED
CONTACT CLOSED
NOT POSSIBLE
DANGEROUS
CAUTION
In order to NOT DAMAGE the interlock circuitry, we recommend using "dry
circuit" (zero voltage) switches or relay circuitry.
Содержание VLASE IR 1109-1 42 Series
Страница 1: ...VLASE IR USER MANUAL InfraRed Laser Marker ...
Страница 72: ...USE AND OPERATION 64 VLASE IR ...
Страница 98: ...LABELS 90 VLASE IR Positioning of labels on the resonator Figure 2 External labels rsonator location ...
Страница 101: ...PERFORMANCE LEVEL PL USER MANUAL 93 BLOCK DIAGRAM ...
Страница 121: ...THERMALIZATION AND SUPPRESSION OF GIANT PULSES USER MANUAL 113 ...
Страница 133: ...USER MANUAL 125 APPENDIX G MECHANICAL DRAWINGS ...
Страница 134: ...MECHANICAL DRAWINGS 126 VLASE IR CONTROL RACK NOTE Please refer to Datalogic website for detailed drawings ...
Страница 135: ...RESONATOR USER MANUAL 127 RESONATOR NOTE Please refer to Datalogic website for detailed drawings ...