Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a good
read. The good read LED on time can be set within a range of 0.1 to 25.5 seconds in 100ms
increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good read
LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with
leading zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
4. Scan the bar code: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in
representing the
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See the table below for examples of how to set this feature.
Table 17. Good Read LED Duration Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Good Read LED
stays on until
next trigger pull
(00)
200ms
1500ms (1.5
sec.)
2500ms (2.5 sec.)
2
Divide by 100 (and pad with
leading zeroes)
000
002
015
025
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT GOOD READ LED DURATION SETTING
5
Scan Three Characters From
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘2’
‘0’, ‘1’ and ‘5’
‘0’, ‘2’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание Touch 90 pro
Страница 10: ...Contents viii Touch TD1100 NOTES...
Страница 14: ...Introduction Technical Support 4 Touch TD1100 NOTES...
Страница 34: ...24 Touch TD1100 NOTES...
Страница 44: ...Enter Exit Programming Mode Enable Character 34 Touch TD1100 NOTES...
Страница 56: ...Enter Exit Programming Mode USB Keyboard Speed 46 Touch TD1100 NOTES...
Страница 96: ...Enter Exit Programming Mode Scanning Features 86 Touch TD1100 NOTES...
Страница 260: ...250 Touch TD1100 NOTES...
Страница 296: ...Technical Specifications 286 Touch TD1100 NOTES...
Страница 312: ...Sample Bar Codes 302 Touch TD1100 Interleaved 2 of 5 Code 32 Codabar Code 93 Code 11 12345678901231...
Страница 314: ...Sample Bar Codes 304 Touch TD1100 NOTES...
Страница 316: ...Keypad 306 Touch TD1100 6 7 8 9 A B C...
Страница 317: ...Product Reference Guide 307 D E F...
Страница 318: ...Keypad 308 Touch TD1100 NOTES...