background image

Product Reference Guide

                           1

Chapter 1

Introduction

About this Manual

This Product Reference Guide (PRG) is provided for users seeking advanced 

technical information, including connection, programming, maintenance 

and specifications. The Quick Reference Guide (QRG) and other publications 

associated with this product are downloadable free of charge from the web-

site listed on the back cover of this manual.

Overview

Chapter 1, 

(this chapter) presents information about manual conventions, 

and an overview of the reader, its features and operation.

Chapter 2, Setup

 presents information about unpacking, cable connection 

information and setting up the reader.

Chapter 3, Configuration Using Bar Codes

 provides instructions and bar 

code labels for customizing your reader. There are different sections for 

interface types, general features, data formatting, symbology-specific and 

model-specific features.

Chapter 4, References

 provides background information and detailed 

instructions for more complex programming items.

Chapter 5, Message Formatting

 gives details for programming options. 

Appendix A, Technical Specifications

 lists physical and performance charac-

teristics, as well as environmental and regulatory specifications. It also pro-

vides standard cable pinouts and LED/Beeper functions.

Appendix B, Sample Bar Codes

 offers sample bar codes for several common 

symbologies.

Appendix C, Standard Defaults

 references common factory default settings 

for reader features and options.

Appendix D, Keypad

 includes numeric bar codes to be scanned for certain 

parameter settings.

Appendix E, Scancode Tables

 lists control character emulation information 

for Wedge and USB Keyboard interfaces.

Содержание PowerScan PD9530

Страница 1: ...PowerScan 9500 Family Product Reference Guide Industrial Corded Handheld Area Imager Bar Code Reader PowerScan PD9530 PBT9500 PM9500...

Страница 2: ...s appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by con tacting your Datalogic representative Electronic versions...

Страница 3: ...Configuration 14 Interface Selection 14 Setting the Interface 14 Customizing Configuration Settings 17 Configure Interface Settings 17 Global Interface Features 17 Configuring Other Features 17 Softw...

Страница 4: ...ID 56 Label ID Control 56 Label ID Symbology Selection 1D Symbologies 57 Advanced Formatting User Label Edit 61 Case Conversion 61 Character Conversion 61 Reading Parameters 63 Double Read Timeout 64...

Страница 5: ...95 UPC EAN Quiet Zones 96 ADD ONS 97 Optional Add ons 97 Optional Add On Timer 98 Optional GS1 128 Add On Timer 100 CODE 39 103 Code 39 Enable Disable 103 Code 39 Check Character Calculation 103 Code...

Страница 6: ...dard 2 of 5 Set Length 1 131 Standard 2 of 5 Set Length 2 132 INDUSTRIAL 2 OF 5 133 Industrial 2 of 5 Enable Disable 133 Industrial 2 of 5 Check Character Calculation 133 Industrial 2 of 5 Check Chara...

Страница 7: ...ength 2 167 PLESSEY 168 Plessey Enable Disable 168 Plessey Check Character Calculation 168 Plessey Check Character Transmission 169 Plessey Length Control 169 Plessey Set Length 1 170 Plessey Set Leng...

Страница 8: ...210 Good Transmission Beep 210 Beep Frequency 210 Beep Duration 211 Beep Volume 212 Disconnect Beep 212 Docking Beep 213 Leash Alarm 213 CONFIGURATION UPDATES 215 Automatic Configuration Update 215 Co...

Страница 9: ...ating Mode 247 Display Off Timeout 248 Backlight Enable 248 Display Contrast 249 Font Size 249 Enable disable buttons 250 Arrow Keys Mode 4 key models only 251 Arrow Up String 4 key models only 251 Ar...

Страница 10: ...y 301 Motion Features 303 Motionless Timeout 303 Wireless Features 304 Automatic Configuration Update 304 RF Address Stamping 304 PM9500 Only Features 306 Changing System Speed in Normal Mode 306 Blue...

Страница 11: ...customizing your reader There are different sections for interface types general features data formatting symbology specific and model specific features Chapter 4 References provides background inform...

Страница 12: ...vely printed copies or prod uct support CDs for most products can be purchased through your Datalogic reseller Technical Support Datalogic Website Support The Datalogic website www datalogic com is th...

Страница 13: ...he Datalogic website See Datalogic Aladdin on page 6 for more information Advancements in the LED technology used in the imager based readers sig nificantly improve the illumination of the target fiel...

Страница 14: ...etect a scanner forgotten somewhere When the button is pressed for longer than 5 seconds all paired scanners will be unpaired The LEDs signal the BC9xx0 BT status as shown in Table 1 on page 4 Table 1...

Страница 15: ...en the battery is used in devices other than the designated product it may damage the battery or reduce its life expectancy If the device causes an abnormal current to flow it may cause the battery to...

Страница 16: ...r face Customizable settings for many features are found in Configuration Parameters starting on page 21 Some programming labels like Restore Custom Defaults on page 18 require only the scan of the si...

Страница 17: ...l shipping container Setting Up the Reader Follow the steps below to connect and get your reader up and communicat ing with its host 1 Begin by Installing the Interface Cable Corded or Connecting the...

Страница 18: ...Ensure that the Front marking on the Cable Holder is facing out with the arrow pointing towards the front of the scanner 4 Insert the end of the cable into the socket of the Cable Holder 5 Push the Co...

Страница 19: ...e for desktop usage or affixed vertically to a wall Mounting Brackets The cradle comes with two different mounting brackets The appropriate bracket is used depending on whether the cradle will be moun...

Страница 20: ...wn in Figure 1 on page 9 into place on the sides 4 Replace the screw to secure the Bracket to the Base Station Figure 2 Changing the Bracket 1 2 3 Permanent Mounting For either desktop or wall mountin...

Страница 21: ...ur face For additional security on wall mounting it is strongly recommended that the cradle be secured into place using two auxiliary screws through the mounting holes on the side Mounting the Metal P...

Страница 22: ...e then both can be mounted to a wall as described above Figure 5 Attaching Mounting Plate to Base Base with Mount attached System Connections CAUTION Connections should always be made with power off T...

Страница 23: ...imilar object into the hole corresponding to the Host connector on the body of the cradle Push down on the clip while unplugging the cable Refer to the following figures Power Interface Emulation to H...

Страница 24: ...election Upon completing the physical connection between the reader and its host proceed to Table 2 on page 15 to select the interface type the reader is con nected to for example RS 232 Keyboard Wedg...

Страница 25: ...OPOS USB FEATURES P HA47 P CR Select USB COM STDa a Download the correct USB Com driver from www datalogic com USB Com to simulate RS 232 standard interface Set USB OEM Interface Features starting on...

Страница 26: ...286 50 50Z 60 70 80 90 95 w Standard Key Encoding P HA29 P CR Select KBD AT P HA11 P CR Select KBD AT NK Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2...

Страница 27: ...ng Other Features If your installation requires different programming than the standard factory default settings the following sections of this manual allow configuration of non interface specific set...

Страница 28: ...e machine from a known status set in the factory or by the customer via configuration file The machine is set as it arrived to you from the factory or according to the custom configuration file you lo...

Страница 29: ...e host computer 3 Use the host computer s Bluetooth manager to Discover new devices and select Datalogic Scanner If you receive an error message it may be necessary to disable security on the device 4...

Страница 30: ...security on the device 4 Use a text editor to see incoming data on the port designated by the computer s Bluetooth manager Link to PC in HID The Powerscan BT9500 can be set up to require a PIN code w...

Страница 31: ...ind the desired function based on its reference group Interface Configuration RS 232 Only Interface on page 25 RS 232 USB Com Interfaces on page 30 Keyboard EMULATION Settings on page 37 Parameters co...

Страница 32: ...eed to cover unused bar codes on the page and possibly the facing page to ensure that the reader reads only the bar code you intend to scan 3 If additional input parameters are needed go to Appendix D...

Страница 33: ...ds When set to ignore the reader will ignore all host commands except those necessary for service mode flash programming mode keeping the interface active transmission of labels DEFAULT CIFIH00 CR Hos...

Страница 34: ...Enter Exit Programming Mode 24 PowerScan PD9530 PBT9500 PM9500 NOTES...

Страница 35: ...amming bar codes in this section if modifications to the stan dard RS 232 interface settings are necessary to meet your system s require ments Additional settings which apply to both the RS 232 and US...

Страница 36: ...e See page 272 for information on this feature CR2BA00 CR Baud Rate 1200 CR2BA01 CR Baud Rate 2400 CR2BA02 CR Baud Rate 4800 CR2BA03 CR Baud Rate 9600 CR2BA04 CR Baud Rate 19 200 CR2BA05 CR Baud Rate...

Страница 37: ...th devices requiring a 7 bit or 8 bit ASCII protocol for sending and receiving data CR2DA00 CR 7 Data Bits CR2DA01 CR 8 Data Bits DEFAULT Stop Bits Set the number of stop bits to match host device req...

Страница 38: ...PM9500 Parity This feature specifies parity required for sending and receiving data Select the parity type according to host device requirements See page 272 for more information DEFAULT CR2PA00 CR P...

Страница 39: ...DEFAULT CR2HC00 CR Handshaking Control RTS CR2HC01 CR Handshaking Control RTS CTS CR2HC02 CR Handshaking Control RTS XON XOFF CR2HC03 CR Handshaking Control RTS On CTS CR2HC04 CR Handshaking Control...

Страница 40: ...RACTER on page 33 ACK NAK TIMEOUT VALUE on page 34 ACK NAK RETRY COUNT on page 34 ACK NAK ERROR HANDLING on page 35 INDICATE TRANSMISSION FAILURE on page 35 DISABLE CHARACTER on page 36 ENABLE CHARACT...

Страница 41: ...RAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Appendix D Keypad repre senting your desired character s End by scanning the ENTER EXI...

Страница 42: ...able DEFAULT CBPNF01 CR Beep On Not On File Enable ACK NAK Options This enables disables the ability of the reader to support the RS 232 ACK NAK protocol See page 274 for more information DEFAULT CR2A...

Страница 43: ...ts with normal operation of these characters 8 bit data is not recognized when the option Data Bits has been set as 7 Data Bits NAK Character This setting specifies an ASCII character or hex value to...

Страница 44: ...stake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 01 ACK NAK Timeout value is 200ms ACK NAK Retry Count This feature specif...

Страница 45: ...Ignore Errors Detected CR2EH01 CR ACK NAK Error Handling Process Error as Valid ACK Char acter CR2EH02 CR ACK NAK Error Handling Process Error as Valid NAK Character Indicate Transmission Failure This...

Страница 46: ...e 278 for more information on setting this feature CR2DC Select Disable Character Setting DEFAULT 0x44 Disable Character is D Enable Character Specifies the value of the RS 232 host command used to en...

Страница 47: ...43 NUMLOCK on page 43 USB KEYBOARD SPEED on page 44 USB KEYBOARD NUMERIC KEYPAD on page 45 Use the programming bar codes in this chapter to select options for USB Keyboard and Wedge Interfaces Referen...

Страница 48: ...1 CR Country Mode Belgium CKBCO02 CR Country Mode Britain CKBCO11 CR Country Mode Croatia Supports only the interfaces listed in the Country Mode feature description Supports only the interfaces liste...

Страница 49: ...Mode Germany Supports only the interfaces listed in the Country Mode feature description CKBCO0D CR Country Mode Hungary CKBCO06 CR Country Mode Italy Supports only the interfaces listed in the Count...

Страница 50: ...de feature description CKBCO08 CR Country Mode Portugal CKBCO10 CR Country Mode Romania Supports only the interfaces listed in the Coun try Mode feature description Supports only the interfaces listed...

Страница 51: ...control charac ter Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from 00 to 0x1F are sent as control charac ter Ctrl Shift special keys are located from 0x80 to...

Страница 52: ...XIT bar code again Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 0A Quiet Interval is 100 milliseconds Interco...

Страница 53: ...n an alternate key encoding keyboard is selected DEFAULT CKBCL00 CR Caps Lock State Caps Lock OFF CKBCL01 CR Caps Lock State Caps Lock ON CKBCL02 CR Caps Lock State AUTO Caps Lock Enable Numlock This...

Страница 54: ...the USB poll rate for a USB keyboard DEFAULT CKBSP01 CR USB Keyboard Speed 1ms CKBSP02 CR USB Keyboard Speed 2ms CKBSP03 CR USB Keyboard Speed 3ms CKBSP04 CR USB Keyboard Speed 4ms CKBSP05 CR USB Keyb...

Страница 55: ...SP0A CR USB Keyboard Speed 10ms Enter Exit Programming Mode Product Reference Guide 45 USB Keyboard Speed continued USB Keyboard Numeric Keypad This option Controls whether numeric characters will be...

Страница 56: ...Enter Exit Programming Mode 46 PowerScan PD9530 PBT9500 PM9500 NOTES...

Страница 57: ...USB interfaces differ depending upon which host type the reader will be connected with Use the feature settings in this chapter to specifically configure for the USB OEM interface Other USB interface...

Страница 58: ...ting to enable all devices to communicate Options are Table Top Scanner Handheld Scanner CIBUT00 CR USB OEM Device Usage Table Top Scanner CIBUT01 CR USB OEM Device Usage Handheld Scanner DEFAULT It m...

Страница 59: ...ually Set Label ID Label ID Control Label ID Symbology Selection 1D Symbol ogies Label ID Symbology Selection 2D Symbol ogies CASE CONVERSION on page 61 CHARACTER CONVERSION on page 61 The features in...

Страница 60: ...feature scan the ENTER EXIT PROGRAMMING MODE bar code above to place the unit in Programming Mode then the Set Global Prefix or Set Global Suffix bar code followed by the digits in hex from the Alphan...

Страница 61: ...bel identifiers consist of three characters as follows A close brace character ASCII followed by A code character see some samples in the table below followed by A modifier character the modifier char...

Страница 62: ...EXPANDED e 65 DATABAR EXPANDED COMPOSITE e 65 DATABAR LIMITED e 65 DATABAR LIMITED COMPOSITE e 65 DATA MATRIX d 64 EAN128 C 43 EAN128 COMPOSITE C 43 EAN13 E 45 EAN13 P2 E 45 EAN13 P5 E 45 EAN13 COMPOS...

Страница 63: ...50 POSTAL AUSTRALIAN X 58 POSTAL IMB X 58 POSTAL JAPANESE X 58 POSTAL KIX X 58 POSTAL PLANET X 58 POSTAL PORTUGAL X 58 POSTAL POSTNET BB X 58 POSTAL ROYAL MAIL X 58 POSTAL SWEDISH X 58 POSTNET X 58 Q...

Страница 64: ...individually for the GS1 128 symbology and the programming for this works the same way as Label ID See Label ID Set Individually Per Symbology starting on page 291 for detailed instruc tions on setti...

Страница 65: ...the reader to always include an industry standard label identifier for ALL symbology types see the previous feature Global AIM ID on page 51 See Label ID starting on page 288 of References for more in...

Страница 66: ...on page 57 to select the symbology you want to set followed by up to 3 characters from the ASCII Chart at the back of this man ual See Label ID Set Individually Per Symbology on page 291 for detailed...

Страница 67: ...lian Postal Code Label ID Character s CI8ID Set Concatenated ISBT 128 Label ID Character s CCBID Set Codabar Label ID Character s CDPID Set Danish PPT Label ID Character s CC1ID Set Code 11 Label ID C...

Страница 68: ...D Character s C85ID Set EAN 8 P5 Label ID Character s CLBID Set GSI DataBar Limited Label ID Character s CF2ID Set Follett 2 of 5 Label ID Character s CLCID GSI DataBar Limited Composite Label ID Char...

Страница 69: ...lessey Label ID Character s CISID Set ISBN Label ID Character s CPGID Set Portugal Postal Code Label ID Character s CINID Set ISSN Label ID Character s CPNID Set Postnet Label ID Character s CPJID Set...

Страница 70: ...Character s CAZID Set Aztec Label ID Character s CMXID Set Maxicode Label ID Character s CCSID Set China Sensible Label ID Character s CP4ID Set PDF 417 Label ID Character s CCFID Set Codablock F Lab...

Страница 71: ...on affects ONLY scanned bar code data and does not affect Label ID Prefix Suffix or other appended data Character Conversion Character conversion is an eight byte configuration item The eight bytes ar...

Страница 72: ...62 PowerScan PD9530 PBT9500 PM9500 NOTES...

Страница 73: ...UENCY on page 67 AIMING DURATION TIMER on page 76 GOOD READ BEEP LENGTH on page 68 GREEN SPOT DURATION on page 77 GOOD READ BEEP VOLUME on page 69 PARTIAL LABEL READING CONTROL on page 77 GOOD READ LE...

Страница 74: ...same label again within the specified timeout the second read is ignored Double Read Timeout does not apply to scan modes that require a trigger pull for each label read CSNDR0A CR Double Read Timeou...

Страница 75: ...r Exit Programming Mode Product Reference Guide 65 Double Read Timeout continued CSNDR50 CR Double Read Timeout 0 8 Second CSNDR5A CR Double Read Timeout 0 9 Second CSNDR64 CR Double Read Timeout 1 Se...

Страница 76: ...On Alert Disable No Audible Indication CBPPU01 CR Power On Alert Power up Beep DEFAULT Good Read When to Indicate This feature specifies when the reader will provide indication beep and or flash its g...

Страница 77: ...ood Read Beep Type Mono CBPTY01 CR Good Read Beep Type Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low medium or high frequency selectable from the list below...

Страница 78: ...ngth 60 msec CBPLE08 CR Good Read Beep Length 80 msec DEFAULT CBPLE0A CR Good Read Beep Length 100 msec CBPLE0C CR Good Read Beep Length 120 msec CBPLE0E CR Good Read Beep Length 140 msec CBPLE10 CR G...

Страница 79: ...Volume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels CBPVO00CR Good Read Beep Volume Beeper Off CBPVO01CR Good Read Beep Volume Low CBPVO02CR Good...

Страница 80: ...d examples for set ting this feature CLAGL00 CR Good Read LED Duration Setting Keep LED on until next trigger pull CLAGL Select Good Read LED Duration Setting To configure this feature scan the ENTER...

Страница 81: ...Selects the reader s scan operating mode See page 295 in References for descriptions CSNRM00 CR Scan Mode Trigger Single DEFAULT CSN Scan Mode Trigger Hold Multiple CSNRM02 CR Scan Mode Trigger Pulse...

Страница 82: ...0 CR Stand Mode Indication Disable CSMFL01 CR Stand Mode Indication Enable Pick Mode Specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern T...

Страница 83: ...reader illumination stays off after pulling the trigger when in Stand Mode The configurable range is 01 to 32 by 01 in increments of 500ms 500ms to 16 seconds See page 296 in References for a descrip...

Страница 84: ...ge 297 in References for further description of this feature CSNET03 CR Scanning Active Time 3 seconds CSNET05 CR Scanning Active Time 5 seconds DEFAULT CSNET08 CR Scanning Active Time 8 seconds Stand...

Страница 85: ...de to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT 10 Flash is ON for 1 Second Flash Off Time This feature specifies the OFF time for the indicator LED...

Страница 86: ...ting is from 1 to 255 seconds in 1 second increments See page 298 in References for a description of this feature DEFAULT LSTM00 Aiming Off After Decoding LSTM Set Aiming Duration Timer To configure s...

Страница 87: ...Green Spot is Off CLSSP01 CR Green Spot Duration Short 300 msec DEFAULT CLSSP02 CR Green Spot Duration Medium 500 msec CLSSP03 CR Green Spot Duration Long 800 msec Partial Label Reading Control Enable...

Страница 88: ...additional options see the Aladdin configuration application CAUTION P CIPVR00 P C R Decode Negative Image Disable DEFAULT P CIPVR01 P CR Decode Negative Image Enable When this feature is enabled you...

Страница 89: ...ding Mode is enabled the scanner keeps on processing the image until all the labels present are decoded The reader then sorts the data from all the bar codes if configured to do so before transmitting...

Страница 90: ...ar code above then the bar code at left followed by the digits From the alphanu meric characters In Appendix d keypad representing your desired Character s end by scanning the enter exit bar code agai...

Страница 91: ...ed page 157 Code 39 LaPoste page 112 Code 93 page 158 Code 39 PZN page 112 MSI page 163 Code 128 page 113 Plessey page 168 Default settings are indicated at each feature option with a green arrow Also...

Страница 92: ...feature to disable all symbologies 1 Scan the ENTER EXIT PROGRAMMING Mode bar code 2 Scan the Disable All Symbologies bar code 3 Complete the programming sequence by scanning the ENTER EXIT PROGRAMMIN...

Страница 93: ...l This feature is used to control the reader s method of processing coupon labels CCPLC00 CR Coupon Control Allow all coupon bar codes to be decoded CCPLC01 CR Coupon Control Enable only UPCA coupon d...

Страница 94: ...en disabled the reader will not read UPC A bar codes CABEN00 CR UPC A Disable CABEN01 CR UPC A Enable DEFAULT UPC A Check Character Transmission Enable this option to transmit the check character alon...

Страница 95: ...mbology ID to match those required for EAN 13 DEFAULT CAB3B00 CR UPC A to EAN 13 Don t Expand CAB3B01 CR UPC A to EAN 13 Expand UPC A Number System Character Transmission This feature enables disables...

Страница 96: ...n a base label of this symbology is decoded DEFAULT CAB2D00 CR EAN 13 2D Component Disable 2D component not required CAB2D01 CR EAN 13 2D Component 2D component must be decoded UPC E The following opt...

Страница 97: ...UPC E Check Character Transmission Don t Send CEBCT01 CR UPC E Check Character Transmission Send DEFAULT UPC E 2D Component This feature enables disables a requirement that a 2D label component be dec...

Страница 98: ...format Selecting this feature also changes the symbology ID to match those required for EAN 13 DEFAULT CEB3B00 CR UPC E to EAN 13 Don t Expand CEB3B01 CR UPC E to EAN 13 Expand Expand UPC E to UPC A...

Страница 99: ...it CEBNS01 CR UPC E Number System Character Transmit DEFAULT GTIN FORMATTING This feature enables disables the ability to convert UPC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character format...

Страница 100: ...When disabled the reader will not read EAN 13 JAN 13 bar codes C3BEN00 CR EAN 13 Disable C3BEN01 CR EAN 13 Enable DEFAULT EAN 13 Check Character Transmission Enable this option to transmit the check c...

Страница 101: ...er is the first character of the label C3BF100 CR EAN 13 Flag 1 Char Don t transmit C3BF101 CR EAN 13 Flag 1 Char Transmit DEFAULT EAN 13 ISBN Conversion This option enables disables conversion of EAN...

Страница 102: ...of this symbology is decoded DEFAULT C3B2D00 CR EAN 13 2D Component Disable 2D component not required C3B2D01 CR EAN 13 2D Component 2D component must be decoded ISSN The following options apply to th...

Страница 103: ...n disabled the reader will not read EAN 8 JAN 8 bar codes C8BEN00 CR EAN 8 Disable C8BEN01 CR EAN 8 Enable DEFAULT EAN 8 Check Character Transmission Enable this option to transmit the check character...

Страница 104: ...8B3B00 CR Expand EAN 8 to EAN 13 Disable C8B3B01 CR Expand EAN 8 to EAN 13 Enable EAN 8 2D Component This feature enables disables a requirement that a 2D label component be decoded when a base label...

Страница 105: ...feature description UPC EAN Price Weight Check This feature enables disables calculation and verification of price weight check digits DEFAULT CPWEN00 CR Price Weight Check Disabled CPWEN01 CR Price W...

Страница 106: ...t zones for UPC EAN labels Quiet zones are blank areas at the ends of a bar code typically 10 times the width of the narrowest bar or space in the label The property applies to all EAN UPC symbologies...

Страница 107: ...al Add Ons Enable P2 DEFAULT CADO500 CR Optional Add Ons Disable P5 CADO501 CR Optional Add Ons Enable P5 DEFAULT CADO800 CR Optional Add Ons Disable GS1 128 CADO801 CR Optional Add Ons Enable GS1 128...

Страница 108: ...tional add ons are enabled Also see Optional GS1 128 Add On Timer on page 100 CADOT01 CR Optional Add on Timer 10ms CADOT02 CR Optional Add on Timer 20ms CADOT03 CR Optional Add on Timer 30ms CADOT04...

Страница 109: ...dd on Timer 160ms CADOT12 CR Optional Add on Timer 180ms CADOT14 CR Optional Add on Timer 200ms CADOT16 CR Optional Add on Timer 220ms CADOT18 CR Optional Add on Timer 240ms CADOT1A CR Optional Add on...

Страница 110: ...On Timer This option sets the timer expiration value to read the added part after reading the linear EAN UPC part For UPC EAN add ons other than those of that type see Optional Add On Timer on page 98...

Страница 111: ...er 40ms CADUT05 CR Optional GS1 128 Add On Timer 50ms CADUT06 CR Optional GS1 128 Add On Timer 60ms CADUT07 CR Optional GS1 128 Add On Timer 70ms CADUT0A CR Optional GS1 128 Add On Timer 100ms CADUT0C...

Страница 112: ...1 128 Add On Timer 220ms CADUT18 CR Optional GS1 128 Add On Timer 240ms CADUT1A CR Optional GS1 128 Add On Timer 260ms CADUT1C CR Optional GS1 128 Add On Timer 280ms CADUT1E CR Optional GS1 128 Add On...

Страница 113: ...Character Calculation Enable this option to enables disables calculation and verification of an optional Code 39 check character When disabled any check character in the label is treated as a data ch...

Страница 114: ...r along with Code 39 bar code data CC3CT00 CR Code 39 Check Character Transmission Don t Send CC3CT01 CR Code 39 Check Character Transmission Send DEFAULT Code 39 Check Character Calculation continued...

Страница 115: ...39 start and stop characters DEFAULT CC3SS00 CR Code 39 Start Stop Character Transmission Don t Transmit CC3SS01 CR Code 39 Start Stop Character Transmission Transmit Code 39 Full ASCII Enables disabl...

Страница 116: ...uiet Zones Quiet Zones on two sides CC3LO03 CR Code 39 Quiet Zones Small Quiet Zones on two sides DEFAULT Code 39 Length Control This feature specifies either variable length decoding or fixed length...

Страница 117: ...ng Length 1 See page 283 for detailed instructions on setting this feature Table 4 Code 39 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Characters 07 Characters 15 Characters 50...

Страница 118: ...mples for setting Length 2 See page 284 for detailed instructions on setting this feature Table 5 Code 39 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Ignore This Length 07 Char...

Страница 119: ...RMACEUTICAL CODE The following options apply to the Code 32 Italian Pharmaceutical Code symbology Code 32 Enable Disable When disabled the reader will not read Code 32 bar codes DEFAULT CP3EN00 CR Cod...

Страница 120: ...ta DEFAULT CP3CT00 CR Code 32 Check Character Transmission Don t Send CP3CT01 CR Code 32 Check Character Transmission Send Code 32 Start Stop Character Transmission This option enables disables transm...

Страница 121: ...Disables ability of the reader to decode Code 39 CIP labels DEFAULT CCCEN00 CR Code 39 CIP Disable CCCEN01 CR Code 39 CIP Enable CODE 39 DANISH PPT The following options apply to the Code 39 Danish PP...

Страница 122: ...disables the ability of the scanner to decode Code39 La Poste labels DEFAULT CLPEN00 CR Code 39 LaPoste Disable CLPEN01 CR Code 39 LaPoste Enable CODE 39 PZN The following options apply to the Code 39...

Страница 123: ...nable Disable When disabled the reader will not read Code 128 bar codes CC8EN00 CR Code 128 Disable CC8EN01 CR Code 128 Enable DEFAULT Expand Code 128 to Code 39 This feature enables disables expansio...

Страница 124: ...r code data DEFAULT CC8CT00 CR Code 128 Check Character Transmission Don t Send CC8CT01 CR Code 128 Check Character Transmission Send Code 128 Function Character Transmission Enables disables transmis...

Страница 125: ...change Transmission Disable CC8SC01 CR Code 128 Sub Code Exchange Transmission Enable Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels Quiet zones are blank ar...

Страница 126: ...128 Length Control This feature specifies either variable length decoding or fixed length decod ing for the Code 128 symbology See page 283 for more information DEFAULT CC8LC00 CR Code 128 Length Con...

Страница 127: ...ength 1 See page 283 for detailed instructions on setting this feature Table 6 Code 128 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 15 Characters 80 Cha...

Страница 128: ...Table 7 provides examples for setting Length 2 See page 284 for detailed instructions on setting this feature Table 7 Code 128 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Igno...

Страница 129: ...mit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do not transmit GS1 128 labels CU8EN00CR GS1 128 Transmit in Code 128 data format CU8EN01CR GS1 128 Transmit i...

Страница 130: ...sable ISBT128 concatenation of 2 labels DEFAULT CI8CE00 CR ISBN 128 Concatenation Disable CI8CE01 CR ISBN 128 Concatenation Enable ISBT 128 Force Concatenation When enabled this feature forces concate...

Страница 131: ...ation Mode Specifies the concatenation mode between Static and Dynamic DEFAULT CI8CM00CR ISBT 128 Concatenation Mode Static CI8CM01CR ISBT 128 Concatenation Mode Dynamic This option is only valid when...

Страница 132: ...ion Timeout 100 msec DEFAULT CI8DT14 CR ISBT 128 Dynamic Concatenation Timeout 200 msec CI8DT32 CR ISBT 128 Dynamic Concatenation Timeout 500 msec CI8DT4B CR ISBT 128 Dynamic Concatenation Timeout 750...

Страница 133: ...ence Guide 123 INTERLEAVED 2 OF 5 I 2 OF 5 The following options apply to the I 2 of 5 symbology I 2 of 5 Enable Disable When disabled the reader will not read I 2 of 5 bar codes DEFAULT CI2EN00 CR I...

Страница 134: ...r contact Technical Support DEFAULT CI2CC00 CR I 2 of 5 Check Character Calculation Disable CI2CC01 CR I 2 of 5 Check Character Calculation Check Standard Modulo 10 CI2CC02 CR I 2 of 5 Check Character...

Страница 135: ...R I 2 of 5 Check Character Transmission Send DEFAULT I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decod ing for the I 2 of 5 symbology Variable Length...

Страница 136: ...gth 1 See page 283 for detailed instructions on setting this feature Table 8 I 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 2 Characters 6 Characters 14 Characters 50 Charac...

Страница 137: ...for setting Length 2 See page 284 for detailed instructions on setting this feature Table 9 I 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting Ignore This Length 4 Characters 14...

Страница 138: ...s Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels DEFAULT CCHEN00 CR Interleaved 2 of 5 CIP HR Disable CCHEN01 CR Interleaved 2 of 5 CIP HR Enable FOLLETT 2 OF 5 The following op...

Страница 139: ...not read Standard 2 of 5 bar codes DEFAULT C2SEN00 CR Standard 2 of 5 Disable C2SEN01 CR Standard 2 of 5 Enable Standard 2 of 5 Check Character Calculation This option enables disables calculation and...

Страница 140: ...andard 2 of 5 Check Character Transmission Send DEFAULT Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decod ing for the Standard 2 of 5 symbolog...

Страница 141: ...g Length 1 See page 283 if you want detailed instructions on setting this feature Table 10 Standard 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 1...

Страница 142: ...des examples for setting Length 2 See page 284 for detailed instructions on setting this feature Table 11 Standard 2 of 5 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with lead...

Страница 143: ...eader to decode Industrial 2 of 5 labels DEFAULT CU2EN00 CR Industrial 2 of 5 Disable CU2EN01 CR Industrial 2 of 5 Enable Industrial 2 of 5 Check Character Calculation Enables Disables calculation and...

Страница 144: ...2 of 5 Check Character Transmission Enable DEFAULT Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decod ing for the Industrial 2 of 5 symbolog...

Страница 145: ...gth 1 See page 283 if you want detailed instructions on setting this feature Table 12 Industrial 2 of 5 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 Characters 07 Characters 15...

Страница 146: ...s length only one fixed length Table 13 provides examples for setting Length 2 See page 284 for detailed instructions on setting this feature Table 13 Industrial 2 of 5 Length 2 Setting Examples STEP...

Страница 147: ...les the ability of the reader to decode IATA labels DEFAULT CIAEN00 CR IATA Disable CIAEN01 CR IATA Enable IATA Check Character Transmission Enables Disables calculation and verification of an optiona...

Страница 148: ...bar Enable Codabar Check Character Calculation Enable this option to enables disables calculation and verification of an optional Codabar check character When disabled any check character in the label...

Страница 149: ...00 CR Codabar Check Character Transmission Don t Send CCBCT01 CR Codabar Check Character Transmission Send DEFAULT Codabar Start Stop Character Transmission Enable this option to enable disable transm...

Страница 150: ...Set ABCD TN E CCBSC01 CR Codabar Check Character Set ABCD ABCD CCBSC02 CR Codabar Check Character Set abcd tn e CCBSC03 CR Codabar Check Character Set abcd abcd DEFAULT Codabar Start Stop Character M...

Страница 151: ...Quiet Zones Quiet Zones on two sides CCBLO03 CR Codabar Quiet Zones Small Quiet Zones on two sides Codabar Length Control This feature specifies either variable length decoding or fixed length decod...

Страница 152: ...able 14 provides some examples for setting Length 1 See page 283 for detailed instructions on setting this feature Table 14 Codabar Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting and...

Страница 153: ...length only one fixed length Table 15 provides examples for setting Length 2 See page 284 for detailed instructions on setting this feature Table 15 Codabar Length 2 Setting Examples STEP ACTION EXAMP...

Страница 154: ...Enable Disable Enables Disables ability of reader to decode ABC Codabar labels DEFAULT CCBAB00 CR ABC Codabar Disable CCBAB01 CR ABC Codabar Enable ABC Codabar Concatenation Mode Specifies the concate...

Страница 155: ...on Mode CCBDT05 CR ABC Codabar Dynamic Concatenation Timeout 50 msec CCBDT0A CR ABC Codabar Dynamic Concatenation Timeout 100 msec DEFAULT CCBDT14 CR ABC Codabar Dynamic Concatenation Timeout 200 msec...

Страница 156: ...PowerScan PD9530 PBT9500 PM9500 ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated DEFAULT CCBFC00 CR ABC Codabar Force Concatenation Disable CCBFC01 CR ABC Cod...

Страница 157: ...0 CR Code 11 Disable CC1EN01 CR Code 11 Enable Code 11 Check Character Calculation This option enables disables calculation and verification of optional Code 11 check character CC1CC00 CR Code 11 Chec...

Страница 158: ...01 CR Code 11 Check Character Transmission Send DEFAULT Code 11 Length Control This feature specifies either variable length decoding or fixed length decod ing for the Code 11 symbology Variable Lengt...

Страница 159: ...th 1 See page 283 for detailed instructions on setting this feature Table 16 Code 11 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with leading zeroes 02 Characters 07 Character...

Страница 160: ...provides examples for setting Length 2 See page 284 for detailed instructions on setting this feature Table 17 Code 11 Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting pad with leading...

Страница 161: ...will not read GS1 DataBar Omnidirectional bar codes DEFAULT C4BEN00 CR GS1 DataBar Omnidirectional Disable C4BEN01 CR GS1 DataBar Omnidirectional Enable GS1 DataBar Omnidirectional GS1 128 Emulation...

Страница 162: ...1 DataBar Omnidirectional 2D Component Disable 2D component not required C4B2D01 CR GS1 DataBar Omnidirectional 2D Component 2D component must be decoded GS1 DATABAR EXPANDED The following options app...

Страница 163: ...AULT CXBU800 CR GS1 DataBar Expanded GS1 128 Emulation Disable CXBU801 CR GS1 DataBar Expanded GS1 128 Emulation Enable GS1 DataBar Expanded 2D Component This feature enables disables a requirement th...

Страница 164: ...coding or fixed length decod ing for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two different le...

Страница 165: ...Length 1 See page 283 for detailed instructions on setting this feature Table 18 GS1 DataBar Expanded Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Character 07 Characters 52 Cha...

Страница 166: ...rovides examples for setting Length 2 See page 284 for detailed instructions on setting this feature Table 19 GS1 DataBar Expanded Length 2 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 00 i...

Страница 167: ...disabled the reader will not read GS1 DataBar Limited bar codes DEFAULT CLBEN00 CR GS1 DataBar Limited Disable CLBEN01 CR GS1 DataBar Limited Enable GS1 DataBar Limited GS1 128 Emulation When enabled...

Страница 168: ...l of this symbology is decoded DEFAULT CLB2D00 CR GS1 DataBar Limited 2D Component Disable 2D component not required CLB2D01 CR GS1 DataBar Limited 2D Component 2D component must be decoded CODE 93 Th...

Страница 169: ...ble CC9CC01 CR Code 93 Check Character Calculation Enable Check C CC9CC02 CR Code 93 Check Character Calculation Enable Check K CC9CC03 CR Code 93 Check Character Calculation Enable Check C and K DEFA...

Страница 170: ...iable length decoding or fixed length decod ing for the Code 93 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding tw...

Страница 171: ...Length 1 See page 283 for detailed instructions on setting this feature Table 20 Code 93 Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Characters 50 C...

Страница 172: ...re this length only one fixed length Table 21 provides examples for setting Length 2 See page 284 for detailed instructions on setting this feature Table 21 CODE 93 Length 2 Setting Examples STEP ACTI...

Страница 173: ...e 93 CC9LO02 CR Code 93 Quiet Zones Quiet Zones on two sides CC9LO03 CR Code 93 Quiet Zones Small Quiet Zones on two sides DEFAULT MSI The following options apply to the MSI symbology MSI Enable Disab...

Страница 174: ...ter Calculation Disable CMSCC01 CR MSI Check Character Calculation Enable Mod10 DEFAULT CMSCC02 CR MSI Check Character Calculation Enable Mod11 10 CMSCC03 CR MSI Check Character Calculation Enable Mod...

Страница 175: ...iable length decoding or fixed length decod ing for the MSI symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two di...

Страница 176: ...for setting Length 1 See page 283 for detailed instructions on setting this feature Table 22 MSI Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Charact...

Страница 177: ...this length only one fixed length Table 23 provides examples for setting Length 2 See page 284 for detailed instructions on setting this feature Table 23 MSI Length 2 Setting Examples STEP ACTION EXAM...

Страница 178: ...able Plessey Check Character Calculation Enables Disables calculation and verification of an optional Plessey check character CPLCC00 CR Plessey Check Character Calculation Disable CPLCC01 CR Plessey...

Страница 179: ...y Check Character Transmission Enable DEFAULT Plessey Length Control This feature specifies either variable length decoding or fixed length decod ing for the Plessey symbology Variable Length For vari...

Страница 180: ...r setting Length 1 See page 283 for detailed instructions on setting this feature Table 24 Plessey Length 1 Setting Examples STEP ACTION EXAMPLES 1 Desired Setting 01 Characters 07 Characters 15 Chara...

Страница 181: ...is length only one fixed length Table 25 provides examples for setting Length 2 See page 284 for detailed instructions on setting this feature Table 25 Plessey Length 2 Setting Examples STEP ACTION EX...

Страница 182: ...172 PowerScan PD9530 PBT9500 PM9500 NOTES...

Страница 183: ...rrow Also reference Appendix C Standard Defaults for a listing of the most widely used set of standard factory settings That sec tion also provides space to record any custom settings needed or imple...

Страница 184: ...e a 2D label The selectable range is 10 milliseconds to 2 55 milliseconds CDETM0A CR 2D Maximum Decoding Time 100 msec CDETM32 CR 2D Maximum Decoding Time 200 msec CDETM23 CR 2D Maximum Decoding Time...

Страница 185: ...Enable 2D Normal Inverse Symbol Control Specifies the options available for decoding normal negative printed 2D symbols This configuration item applies globally to all the 2D symbologies that support...

Страница 186: ...le CAZEN01 CR Aztec Code Enable Aztec Code Length Control This feature specifies either variable length decoding or fixed length decod ing for this symbology Variable Length For variable length decodi...

Страница 187: ...1 pad with zeroes See page 283 for detailed instructions on setting this feature CAZL1 Select Aztec Code Length 1 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE bar code above...

Страница 188: ...ents of 0001 pad with zeroes See page 284 for detailed instructions on setting this feature CAZL2 Select Aztec Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE bar...

Страница 189: ...CSEN01 CR China Sensible Code Enable China Sensible Code Length Control This feature specifies either variable length decoding or fixed length decod ing for this symbology Variable Length For variable...

Страница 190: ...ts of 0001 pad with zeroes See page 283 for detailed instructions on setting this feature CCSL1 Select China Sensible Code Length 1 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MO...

Страница 191: ...ents of 0001 pad with zeroes See page 284 for detailed instructions on setting this feature CCSL2 Select China Sensible Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING...

Страница 192: ...ies the options available when reading Data Matrix with different form factors Choices are Square Style Rectangular Style Both Square and Rectangular Style The configuration item can also be configure...

Страница 193: ...to very conservative depending on a par ticular customer s needs Higher tolerance to poor quality labels increases the reading capability of the scanner See page 283 for more information on this featu...

Страница 194: ...x Length Control Length 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 3 116 characters in increments of...

Страница 195: ...of 0001 pad with zeroes See page 284 for detailed instructions on setting this feature CDML2 Select Data Matrix Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE bar cod...

Страница 196: ...o decode Maxicode labels DEFAULT CMXEN00 CR Maxicode Disable CMXEN01 CR Maxicode Enable Maxicode Primary Message Transmission Enables disables the transmission of only the Primary Message when the Sec...

Страница 197: ...ontrol Length 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 0145 characters in increments of 0001 pad wi...

Страница 198: ...nts of 0001 pad with zeroes See page 284 for detailed instructions on setting this feature CMXL2 Select Maxicode Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE bar cod...

Страница 199: ...R PDF417 Enable DEFAULT PDF417 Length Control This feature specifies either variable length decoding or fixed length decod ing for this symbology Variable Length For variable length decoding a minimum...

Страница 200: ...crements of 01 Any value greater than 2 710 will be considered to be 2 710 See page 283 for detailed instructions on setting this feature CP4L1 Select PDF417 Length 1 Setting To configure this feature...

Страница 201: ...2 710 char acters pad with zeroes in increments of 01 Any value greater than 2 710 will be considered to be 2 710 See page 284 for detailed instructions on setting this feature CP4L2 Select PDF417 Len...

Страница 202: ...e CMIEN01 CR Micro PDF417 Enable Micro PDF417 Code 128 GS1 128 Emulation Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or GS1 128 emulation Emulation choices are Micro PDF AIM...

Страница 203: ...in Variable Length Mode or the first fixed length if in Fixed Length Mode Length includes the bar code s data characters only Characters can be set from 0001 to 0366 characters pad with zeroes in inc...

Страница 204: ...n increments of 01 Any value greater than 0366 will be con sidered to be 0366 See page 284 for detailed instructions on setting this feature CMIL2 Select Micro PDF417 Length 2 Setting To configure thi...

Страница 205: ...R QR Code Enable DEFAULT QR Code Length Control This feature specifies either variable length decoding or fixed length decod ing for this symbology Variable Length For variable length decoding a minim...

Страница 206: ...001 pad with zeroes See page 283 for detailed instructions on setting this feature CQRL1 Select QR Code Length 1 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE bar code above t...

Страница 207: ...2 Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanu meric characters in Ap...

Страница 208: ...Code Length Control Length 1 is the minimum label length if in Variable Length Mode or the first fixed length if in Fixed Length Mode Characters can be set from 0001 to 0035 characters in increments...

Страница 209: ...ents of 0001 pad with zeroes See page 284 for detailed instructions on setting this feature CMQL2 Select QR Code Length 2 Setting To configure this feature scan the ENTER EXIT PROGRAMMING MODE bar cod...

Страница 210: ...SITE UCC Composite Enable Disable Enables disables the ability of the reader to decode the stacked part of a UCC Composite label DEFAULT CCMEN00 CR UCC Composite Disable CCMEN01 CR UCC Composite Enabl...

Страница 211: ...UCC Composite label before transmitting the linear label without an add on DEFAULT CCMOT00 CR UCC Optional Composite Timer Timer Disabled CCMOT01 CR UCC Optional Composite Timer 100msec CCMOT02 CR UC...

Страница 212: ...code labels of a specific postal symbology DEFAULT CPOEN00 CR Postal Code Selection Disable All Postal Codes CPOEN01 CR Postal Code Selection Enable Postnet CPOEN02 CR Postal Code Selection Enable Pla...

Страница 213: ...le Japan Post CPOEN07 CR Postal Code Selection Enable IMB CPOEN08 CR Postal Code Selection Enable Sweden Post CPOEN09 CR Postal Code Selection Enable Portugal Post Postnet BB Control Controls the abil...

Страница 214: ...204 PowerScan PD9530 PBT9500 PM9500 NOTES...

Страница 215: ...6 Use this chapter to configure motion settings for the handheld Reference Appendix C for a listing of standard factory settings Motion Aiming Control Configures the ability of the scanner to Enable D...

Страница 216: ...r than this timeout the software assumes the reader is in a motionless condition This option relates to such features as Aimer On and Stand Mode Object Sense scanning with respect to motion See Motion...

Страница 217: ...on page 215 Copy Configuration to Scanner on page 215 Copy Configuration to Base Station on page 215 BATCH FEATURES starting on page 216 Batch Mode on page 216 Send Batch on page 216 Erase Batch Memor...

Страница 218: ...age 233 HID Country Mode on page 233 PM9500 Only Features STAR Radio Protocol Timeout on page 236 STAR Radio Transmit Mode on page 237 Changing System Speed on page 238 Frequency Agility on page 238 C...

Страница 219: ...58 Set String Terminator on page 259 ADDITIONAL FEATURES FOR 16 KEY MODELS starting on page 260 Last Code Shown Timeout on page 260 Display Time Stamping Mode on page 260 Mode Selection on page 261 Qu...

Страница 220: ...ation When enabled a beep occurs when a Label is correctly transmitted to the base CBTAB00 CR Good Transmission Beep Disable CBTAB01 CR Good Transmission Beep Enable DEFAULT Beep Frequency Adjusts rad...

Страница 221: ...adio specific beep indications CBTBD06 CR Beep Duration 60 msec CBTBD08 CR Beep Duration 80 msec DEFAULT CBTBD0A CR Beep Duration 100 msec CBTBD0C CR Beep Duration 120 msec CBTBD0E CR Beep Duration 14...

Страница 222: ...volume levels CBTBV00 CR Beep Volume Low CBTBV01 CR Beep Volume Medium CBTBV02 CR Beep Volume High DEFAULT Disconnect Beep Enables disables the beep indication that a handheld has become connected or...

Страница 223: ...cond when the handheld goes out of range This is especially useful in instances where the reader might inadvertently have been placed in a bag or cart For this mode to be effective the reader must be...

Страница 224: ...PBT9500 PM9500 Leash Alarm continued CBTLB03 CR Leash Alarm 3 Seconds CBTLB04 CR Leash Alarm 4 Seconds CBTLB05 CR Leash Alarm 5 Seconds CBTLB0A CR Leash Alarm 10 Seconds CBTLB19 CR Leash Alarm 25 Seco...

Страница 225: ...Scanner Scan the following label to copy the current Base Station configuration to the scanner Use this method when the Auto Configuration Update feature is disabled and you want a one time configura...

Страница 226: ...is disconnected from the remote device Manual The handheld will always store labels to Flash memory The user must manually send the stored labels to the remote device using a special batch send label...

Страница 227: ...E label in conjunc tion with this bar code RF Batch Mode Transmit Delay Specifies the delay in 10 msec increments between transmitting labels stored in batch memory DEFAULT CBTTD00 CR RF Batch Mode Tr...

Страница 228: ...nsmission Enables disables the ability of source radio address information to be trans mitted to the host and if so at what position with respect to the label data See page 304 in References for detai...

Страница 229: ...feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the digits from the Alphanumeric char acters in Appendix D Keypad representing your desired characte...

Страница 230: ...code again Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL Current Time Sets the time of the internal Real Time Clock R...

Страница 231: ...221 Date Tx Format Sets the format of the date DEFAULT CDTXF00 r YYYY MM DD ISO 8601 CDTXF01 r YYYYMMDD No ISO CDTXF02 r MMDDYYYY CDTXF03 r DDMMYYYY Time Tx Format Sets the format of the time DEFAULT...

Страница 232: ...r Set Character Separator To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by 2 digits from the Alphanumeric charac ters in Appendix D...

Страница 233: ...eference Guide 223 Date Time Transmission Order Allows the selection of the order of date and time transmission CRFTS00 r Disabled DEFAULT CRFTS01 r ISO 8601 Date T Time CRFTS02 r DateTime CRFTS03 r T...

Страница 234: ...eout feature sets the time for automatically switching the unit off when the imager has been idle CSLPS00 CR Powerdown Timeout Disable CSLPS01 CR Powerdown Timeout 10 minutes CSLPS02 CR Powerdown Time...

Страница 235: ...scanner directly connected to a host through a Bluetooth dongle verify that the scanner and the Bluetooth driver used by the dongle share the same PIN code and the same security level Otherwise the c...

Страница 236: ...Automatic Configuration Update is set to the default Enabled setting the devices must only be relinked If the Automatic Configuration Update is set to Disabled the Security Mode setting must also be u...

Страница 237: ...ter Bluetooth PIN Code To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by the hexadecimal digits from the Alpha numeric characters in...

Страница 238: ...PD9530 PBT9500 PM9500 OTHER BLUETOOTH FEATURES Reconnect Attempt Interval This feature specifies the interval time between reconnection attempts CBTRI01 CR 1 minute DEFAULT CBTRI02 CR 5 minutes CBTRI...

Страница 239: ...es and select Datalogic Scanner Use a text editor to see incoming data on the port des ignated by the computer s Bluetooth manager If you receive an error message it may be necessary to disable securi...

Страница 240: ...Mode feature HID Alt Mode OFF DEFAULT DEFAULT HID Alt Mode ON Bluetooth HID Send Unknown ASCII Char Unknown characters are characters the host does not recognize When Dis able HID Send ASCII Unknown c...

Страница 241: ...rs that can connect to the Base in a Piconet net work CBTMS01 CR Bluetooth Max Client 1 CBTMS02 CR Bluetooth Max Client 2 DEFAULT CBTMS03 CR Bluetooth Max Client 3 CBTMS04 CR Bluetooth Max Client 4 CB...

Страница 242: ...econnect Attempt Mode Enable DEFAULT Set Bluetooth Friendly Name To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by a maximum 64 digit...

Страница 243: ...Power Class 2 HID Country Mode When the Reader is connected with a Bluetooth Adapter in HID mode you may want to set the country for which your PC is localized In order to do that read one of the conf...

Страница 244: ...9500 PM9500 HID Country Mode continued Country Mode Czech Republic Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy Co...

Страница 245: ...e Product Reference Guide 235 HID Country Mode continued Country Mode Norway Country Mode Poland Country Mode Portugal Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia...

Страница 246: ...affic num ber of readers in the same area The selectable range for this feature is from 02 to 25 seconds See page 305 in References for detailed informa tion and examples for setting this feature Set...

Страница 247: ...ansmission as soon as the Base Station has sent the label to the host and host has replied with an acknowledge message DEFAULT ACK from cradle ACK when sent to host ACK from host The Base Station can...

Страница 248: ...ase The Reader and base will link at the new programmed speed Frequency Agility In exceptionally noisy environments or in case of a high concentration of radio devices Star system performance may be i...

Страница 249: ...is programmed See the Radio Range values in Radio Features on page 316 of Technical Specifications Enter Exit Programming Mode Product Reference Guide 239 The frequency agility features are not equal...

Страница 250: ...when switching from normal mode to compatible mode or vice versa Changing from Normal to Compatible Mode PM9500 Handheld 1 With the PM9500 read the Compatible Mode 0 bar code below 2 Now you can link...

Страница 251: ...Now you can link your PM9500 to a BC9xxx in normal mode the PM9500 will inherit the programmed speed from the BC9xxx BC9xxx Base 1 Using Datalogic Aladdin change the Compatible Mode parameter to Low...

Страница 252: ...ion specifies the delimiter character to be placed between the label data and base address when address stamping is enabled CCNAD Set Base Address Delimiter Character To configure this feature scan th...

Страница 253: ...character s If less than the expected string of 8 char acters are selected scan the ENTER EXIT bar code to terminate the string Exit programming mode by scanning the ENTER EXIT bar code again CR4A0 Se...

Страница 254: ...number of cradles in a single network is 16 including the Master if present All cradles in the system must have different addresses RS 485 Slave Maximum Address Specifies the maximum address that can...

Страница 255: ...orking mode in an RS 485 net work DEFAULT CR4RZ00 r Disable Network CR4RZ01 r Enable RS 485 Slave CR4RZ02 r Enable RS 485 Master RS 485 Network Warning Message Enable Disable the ability of Cradle to...

Страница 256: ...e the ability of the cradle to transmit warning messages to the Host regarding wrong reception of data DEFAULT CR4JH00 r Not Transmitted CR4JH01 r Transmitted RS 485 Network Baud Rate Specifies the ba...

Страница 257: ...nly or 16 key models only For more items for the 16 key model see Additional Features for 16 key models starting on page 260 Display Operating Mode Select the operating mode of the display Options are...

Страница 258: ...above then the bar code at left followed by two digits from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scanning the ENTER EXIT bar code again Make a...

Страница 259: ...e at left followed by two digits 00 32 by 01 from the Alphanumeric characters in Appendix D Keypad representing your desired character s End by scan ning the ENTER EXIT bar code again Make a mistake S...

Страница 260: ...onfigure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by 4 digits from the Alphanumeric charac ters in Appendix D Keypad 4 key models only The l...

Страница 261: ...ls only on page 252 CDIAC00 r Function Keys Action Select mode DEFAULT CDIAC01 r String Association Mode Arrow Up String 4 key models only Associate a pre defined string to the Arrow Up key CDAUS Set...

Страница 262: ...left Define the label string by further scanning 32 dig its from the Alphanumeric characters in Appendix D Keypad The digits must be the hexadecimal ASCII representa tion of the desired characters if...

Страница 263: ...ust be kept enabled but isn t required in normal mode this function can be selected to keep it ineffective Whenever an unconfigured function key is pressed an error message appears on the display and...

Страница 264: ...253 End by scanning the ENTER EXIT bar code again Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL DEFAULT CPWET0000 r F2...

Страница 265: ...x D Keypad The first digit must be 0 the following 3 digits must be configured according to the CMD_ID numbers in Table 27 on page 253 End by scanning the ENTER EXIT bar code again Configure Actions f...

Страница 266: ...Function Key you want to program Next scan 4 dig its from the Alphanumeric characters in Appendix D Keypad The first digit must be 0 the following 3 digits must be configured according to the CMD_ID n...

Страница 267: ...ic characters in Appendix D Keypad The digits must be the hexadecimal ASCII representation of the desired characters if less than the expected string of 16 characters are selected scan the ENTER EXIT...

Страница 268: ...the entry string You can then start again at the beginning CANCEL Set String Header Sets the header of the predefined strings CPWED Set String Header To configure this feature scan the ENTER EXIT PRO...

Страница 269: ...from the Alphanumeric charac ters in Appendix D Keypad The digits must be the hexadecimal ASCII representation of the desired characters If less than the expected string of 16 characters are selected...

Страница 270: ...get the desired result CDIST Last Code Shown Timeout To configure this feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by 2 digits 00 63 by 01 from the...

Страница 271: ...ode Mode Can be further configured See the next sec tions for Qty Code operations CDISM00 r Set Normal Mode DEFAULT CDISM01 r Set QtylCode Mode Quantity Field This feature defines the behavior of the...

Страница 272: ...r Qty precedes Code DEFAULT CPWEH01 r Code precedes Qty CPWEH02 r Code transmitted Qty times Quantity Code Separator This feature allows the insertion of a separator between Qty Code pairs DEFAULT CPW...

Страница 273: ...red by toggling the SHIFT key the keys must be pressed once twice or more to obtain the desired letter This command allows you to specify the time which occurs between a key press and the confirmation...

Страница 274: ...0 Barcode data overwrites what is written in the CODE field by keyboard and the code is transmitted 1 Barcode data is appended to any text in the CODE field and the code is transmitted 2 Barcode data...

Страница 275: ...es the keypad echo It works only when the scanner is in simple data input mode no QTY CODE CPWKE00 r Full Keypad echo DEFAULT CPWKE01 r No echo on function key CPWKE02 r No echo on any key Keypress So...

Страница 276: ...le SHIFT function DEFAULT CPWER01 r Enable SHIFT function SHIFT key association This function allows the association of the SHIFT function to one of the fol lowing keys F1 F2 F3 F4 up arrow key CPWEY0...

Страница 277: ...is feature scan the ENTER EXIT PRO GRAMMING MODE bar code above then the bar code at left followed by 8 digits from the Appendix D Key pad The digits must be the hexadecimal ASCII represen tation of t...

Страница 278: ...ad The digits must be the hexadecimal ASCII represen tation of the desired characters End by scanning the ENTER EXIT bar code again Set F4 Label This item allows the user to change the default mnemoni...

Страница 279: ...r code above then the bar code at left followed by 32 digits from the Alphanumeric charac ters in Appendix D Keypad The digits must be the hexadecimal ASCII representation of the desired charac ters I...

Страница 280: ...meric char acters in Appendix D Keypad The digits must be the hexadecimal ASCII representation of the desired characters If less than the expected string of 16 characters are selected scan the ENTER E...

Страница 281: ...ge 283 DATA EDITING on page 285 Global Prefix Suffix on page 286 Global AIM ID on page 286 Label ID on page 288 Character Conversion on page 293 READING PARAMETERS on page 294 Good Read LED Duration o...

Страница 282: ...parity type according to host device requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of...

Страница 283: ...DELAY SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Key pad that represent the duration which was determined in the steps above You will hear a two beep indication after the...

Страница 284: ...these characters 8 bit data is not recognized when the option Data Bits has been set as 7 Data Bits 1 Determine the desired character or value 2 Use the ASCII Chart on the inside back cover of this ma...

Страница 285: ...33 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT NAK CHARACTER SETTING 5 Scan the appropriate two alphanumeric characters from the keypad in A...

Страница 286: ...SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Key pad that represent the duration which was determined in the steps above You will hear a two beep indication after the last...

Страница 287: ...d in Appendix D Key pad that represent the number which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character s...

Страница 288: ...Go to page 36 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT DISABLE CHARACTER SETTING 5 Scan the appropriate two alphanumeric characters from...

Страница 289: ...ired character value 3 Go to page 36 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT ENABLE CHARACTER SETTING 5 Scan the appropriate two alphanum...

Страница 290: ...can the appropriate two digits from the keypad in Appendix D Key pad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If...

Страница 291: ...CTER DELAY SETTING 5 Scan the appropriate two digits from the keypad in Appendix D Key pad that represent the duration which was determined in the steps above You will hear a two beep indication after...

Страница 292: ...hat represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character scan the CANCEL bar code...

Страница 293: ...imum and maximum length may be set Fixed Length For fixed length decoding two different lengths may be set Set Length 1 This feature specifies one of the bar code lengths for Length Control Length 1 i...

Страница 294: ...from 1 to 50 or 0 to ignore this length Pad the number with leading zeroes to yield two digits For example 0 00 5 05 20 20 etc 2 Go to the Set Length page for your selected symbology and scan the ENT...

Страница 295: ...D This function is used to identify and display the common label identifier for its symbology When enabled this ID code will be transmitted before the scanned bar code data OR Additional advanced edit...

Страница 296: ...sired character The corresponding hex number for the character is 24 To enter this selection code scan the 2 and 4 bar codes from Appendix D Keypad If you make a mistake before the last character scan...

Страница 297: ...N Ea a UPC A and UPC E labels are converted to EAN 13 when adding AIM IDs Code 128 GS1 128 C Code 39 and Code 32 A DataBar Omnidirec tional DataBar Expanded e Codabar F Standard 2 of 5 S Interleaved 2...

Страница 298: ...bel IDs Table 38 shows the USA and the EU sets CAUTION When changing from one Label ID set to another all other reader con figuration settings including the host interface type will be erased and set...

Страница 299: ...000 EAN8 COMPOSITE FF 464600 G 244700 FOLLET 2OF5 O 4F0000 O 4F0000 GTIN G 470000 A 244100 GTIN2 G2 473200 B 244200 GTIN5 G5 473500 C 244300 I2OF5 i 690000 N 4E0000 IATA INDUSTRIAL 2OF5 IA 494100 2600...

Страница 300: ...L SWEDISH X 245800 X 245800 POSTNET 1 310000 1 310000 QR CODE QR 515200 y 790000 S25 s 730000 P 500000 TRIOPTIC T 245400 T 245400 UPCA A 410000 C 430000 UPCA P2 A 410000 F 460000 UPCA P5 A 410000 G 47...

Страница 301: ...ted symbology 5 Turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal si...

Страница 302: ...ng on page 57 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the ASCII Chart inside back cover then sca...

Страница 303: ...AB12BA21 it would look as follows after the character con version BB22BB22 The A characters were converted to B characters and the 1 characters were converted to 2 characters Nothing is done with the...

Страница 304: ...SELECT GOOD READ LED DURATION SETTING 5 Scan the appropriate three digits from the keypad in Appendix D Key pad representing the duration which was determined in the steps above You will hear a two b...

Страница 305: ...trigger is pulled continuous scanning is acti vated until Scanning Active Time has elapsed or the trigger has been released and pulled again Double Read Timeout prevents undesired multi ple reads of...

Страница 306: ...an the bar code Set Stand Mode Illuminator Off Time 5 Scan the appropriate two digits from the keypad in Appendix D Key pad that represent the setting which was determined in the steps above You will...

Страница 307: ...Key pad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character scan the CANCEL...

Страница 308: ...D Key pad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character scan the CANC...

Страница 309: ...om the keypad in Appendix D Keypad representing the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last...

Страница 310: ...the keypad in Appendix D Key pad that represent the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last...

Страница 311: ...page 80 and scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING 5 Scan the appropriate two alphanumeric charact...

Страница 312: ...Reserved 3B LABELIMAGE 12 Reserved 3C CAPTURE_IMAGE_LABEL 13 CODE49 3D Reserved 14 UPC E2 3E M2OF5 15 UPC E5 3F D2OF5 16 Reserved 40 PLESSEY65 17 UPC A2 42 ISSN 18 UPC A5 43 ISBT 19 Reserved 44 Reserv...

Страница 313: ...d in Appendix D Key pad representing the duration which was determined in the steps above You will hear a two beep indication after the last character If you make a mistake before the last character s...

Страница 314: ...desired character then find its hexadecimal equivalent on the ASCII Chart on the inside back cover A setting of 00 specifies no delimiter character 2 Go to page 219 and scan the ENTER EXIT PROGRAMMIN...

Страница 315: ...T 5 Scan the appropriate two digits from the keypad in Appendix D Key pad that represent the duration which was determined in the steps above You will hear a two beep indication after the last charact...

Страница 316: ...be used for authentication of the Bluetooth link To set the pin code 1 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Program ming Mode then enable Bluetooth Security Mode on page 226 2 Speci...

Страница 317: ...he Pin Code setting must also be updated in the Base Station using Aladdin After the Base Station has been updated the devices must be relinked Table 51 Bluetooth Pin Code Setting Examples STEP ACTION...

Страница 318: ...References 308 PowerScan PD9530 PBT9500 PM9500 NOTES...

Страница 319: ...hese are reserved for Ser vice mode command Base station can receive host message only if Host Commands Obey Ignore is set to Ignore Message could be sent to the handheld in response to a Label when T...

Страница 320: ...ly selected font Therefore column 6 is 36 pixels from the left border only if you last selected the 6x8 font otherwise it could be 48 or 72 pixels from the left border Font Selection ESC 0 m Normal mo...

Страница 321: ...D control escape sequences are intended to activate the LEDs for short periods of time and can be used in combination with the Beeper The LED and Beeper will be controlled by the system after the enti...

Страница 322: ...Message Formatting 312 PowerScan PD9530 PBT9500 PM9500 NOTES...

Страница 323: ...o 30 VDC 5 VDC 5 Input Current Operating typical 335 mA 135 mA 10V 350 mA Operating max 475 mA 300 mA 10V 480 mA Idle Standby typical 180 mA 60 mA 10V 120 mA PBT9500 and PM9500 models Battery Type Li...

Страница 324: ...6 cm 20 mils 3 70 cm 40 mils 3 110 cm EAN 13 13 mils 4 48 cm 13 13 mils 3 60 cm PDF 417 10 mils 2 25 cm 10 mils 2 30 cm DataMatrix 7 5 mils 7 14 cm 10 mils 4 18 cm 4mil 2 6 cm 10mil 2 20 cm Minimum El...

Страница 325: ...1 Databar Composites GS1 Databar Expanded Stacked GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional MacroPDF Micro PDF417 PDF417 UPC A E Composites French CIP13 Grid Matrix Chinese code High Per...

Страница 326: ...inga pore IDA 910 MHz model USA Canada FCC IC Mexico NOM Cofetel Laser Safety IEC Class 2 Radiation 1 mW Avg Emitted wavelength 650 nm 12ms pulse Beam Divergence 8 4 deg x 8 1 deg plus pattern IEC Cla...

Страница 327: ...g center 433 MHz 910 MHz Programmable Speed 19 2 kb s 115 2 kb s 500 kb s default 36 8 kb s 500 kb s default Typical Range in open air 50 m at 500 kb s 100 m at 19 2 kb s 100 m at 500 kb s 140 m at 36...

Страница 328: ...rface cable Figure 11 Standard Cable Pinouts Handheld The signal descriptions in Table 53 apply to the connector on the reader and are for reference only Table 53 Standard Cable Pinouts Pin RS 232 USB...

Страница 329: ...al setting and duration upon a successful label scan Green Spota a Except when in sleep mode or when a Good Read LED Duration other than 00 is selected flashes momentarily Upon successful read of a la...

Страница 330: ...al PCB 11 Imager Base Station Indications Cordless Models ONLY Base Station Button Indicators BUTTON PUSH EVENT CORDLESS RED INDICATOR GREEN INDICATOR Push at power up force device connection Aladdin...

Страница 331: ...e Guide 321 Appendix B Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types 1D Bar Codes UPC A EAN 13 978033029095 Code 39 Code 128 Code 128 Int...

Страница 332: ...Sample Bar Codes 322 PowerScan PD9530 PBT9500 PM9500 Sample Bar Codes continued Code 32 Codabar 13579 Code 93 Code 11 123456789...

Страница 333: ...ed 1234890hjio9900mnb GS1 DataBar Limited 08672345650916 GS1 DataBar variants must be enabled to read the bar codes below see GS1 DataBar Omnidirectional on page 151 GS1 DataBar 14 GS1 DataBar Omnidir...

Страница 334: ...Bar Codes 324 PowerScan PD9530 PBT9500 PM9500 2D Bar Codes Aztec Datamatrix China Sensible Code MaxiCode Test Message PDF 417 ABCabc Micro PDF 417 BV17453 QR Code 35900G9 Micro QR Code 123456 UCC Com...

Страница 335: ...Table 56 Standard Defaults Parameter Default Your Setting Page Number GLOBAL INTERFACE FEATURES Host Commands Obey Ignore Obey 23 USB Suspend Mode Disable 23 RS 232 ONLY Baud Rate 115200 26 Data Bits...

Страница 336: ...ace Options Ignore Scanner Configu ration Host Commands 48 Data Format Global Prefix Suffix Header Terminator No Global Prefix Global Suffix 0x0D CR 50 Global AIM ID Disable 51 Set AIM ID Individually...

Страница 337: ...Aiming Off After Decoding 76 Green Spot Duration 300 ms 77 Partial Label Reading Control Enable 77 Decode Negative Image Disable 78 Multiple Label Reading Multiple Labels per Frame Disable 79 Multipl...

Страница 338: ...Send 90 EAN 13 Flag 1 Character Transmit 91 EAN 13 ISBN Conversion Disable 91 EAN 13 2D Component 2D Component Not Required 92 ISSN ISSN Enable Disable Disable 92 EAN 8 EAN 8 Enable Disable Enable 93...

Страница 339: ...racter Transmission Don t Send 110 Code 32 Start Stop Character Transmission Don t Transmit 110 Code 39 CIP French Pharmaceutical Code Code 39 CIP Enable Disable Disable 111 Special Codes Code 39 Dani...

Страница 340: ...ion Send 125 I 2 of 5 Length Control Variable 125 I 2 of 5 Set Length 1 6 126 I 2 of 5 Set Length 2 50 127 Interleaved 2 of 5 CIP HR Interleaved 2 of 5 CIP HR Enable Disable Disable 128 Follett 2 of 5...

Страница 341: ...Stop Character Set abcd abcd 140 Codabar Start Stop Character Match Don t Require Match 140 Codabar Quiet Zones Quiet Zones on two sides 141 Codabar Length Control Variable 141 Codabar Set Length 1 3...

Страница 342: ...1 1 155 GS1 DataBar Expanded Set Length 2 74 156 GS1 DataBar Limited GS1 DataBar Limited Enable Disable Disable 157 GS1 DataBar Limited GS1 128 Emulation Disable 157 GS1 DataBar Limited 2D Component...

Страница 343: ...ngth Control Enable 176 Aztec Code Length Control Variable 176 Aztec Code Set Length 1 1 177 China Sensible Code Enable Disable Disable 179 China Sensible Code Length Control Variable 179 China Sensib...

Страница 344: ...1 196 QR Code Set Length 2 7 089 197 Micro QR Code Enable Disable Disable 197 Micro QR Code Length Control Variable 198 Micro QR Code Set Length 1 0001 198 Micro QR Code Set Length 2 0035 199 UCC Com...

Страница 345: ...Date Tx Format YYYY MM DD ISO 8601 221 Time Tx Format hh mm ss ISO 8601 221 Date Time Separator Disable 222 Date Time Transmission Order Disable 223 Powerdown Timeout 30 minutes 224 Features for PBT95...

Страница 346: ...Warning Message Not Transmitted 246 RS 485 Transmission Warning Message Not Transmitted 246 RS 485 Network Baud Rate 9600 246 Display and Keyboard Features Display Operating Mode Local echo mode 247...

Страница 347: ...o both 260 Mode Selection Set Normal Mode 261 Quantity Field Transmit code with default qty 1 261 Quantity Code Send Mode Qty precedes Code 262 Quantity Code Separator No separator 262 Interkey Timeou...

Страница 348: ...ning either of the Restore Factory Configuration commands below will result in the loss of any custom configuration settings for your device Go to Restore Custom Defaults on page 18 if you want to res...

Страница 349: ...Product Reference Guide 339 Appendix D Keypad Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5 6 7 8 9...

Страница 350: ...Keypad 340 PowerScan PD9530 PBT9500 PM9500 Keypad continued A B C D E F Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL...

Страница 351: ...aracter Ctrl Capital Key special keys are located from 0x80 to 0xA1 Control Character 02 Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII tab...

Страница 352: ...E C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C GS C RS C US C S _ 2x SP 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O...

Страница 353: ...02 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9...

Страница 354: ...0 A 091 A 092 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122...

Страница 355: ...112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 01...

Страница 356: ...ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a b c d e f g h i j k l m n o 7x p q r s t u v w x y z Del 8x Sh Sh...

Страница 357: ...3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 9x F12...

Страница 358: ...S _ 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M N O 5x P Q R S T U V W X Y Z _ 6x a B c d e f g h i j k l m n o 7x p q R s t u v w x y z Del 8x Sh Sh Ins Ent keyp F1 F2 F3 F4 F5 F6 F...

Страница 359: ...252 Product Reference Guide 349 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the legacy components of Microsoft Windows in English and...

Страница 360: ...Scancode Tables 350 PowerScan PD9530 PBT9500 PM9500 NOTES...

Страница 361: ...14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F A B C D E F G H I J K L M N O P Q R S T U V...

Страница 362: ...elephone 1 541 683 5700 Fax 1 541 345 7140 2013 2014 Datalogic Inc All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S...

Отзывы: