Enter/Exit Programming Mode
92
PowerScan™ PD9530/PBT9500/PM9500
EAN-13 2D Component
This feature enables/disables a requirement that a 2D label component be
decoded when a base label of this symbology is decoded.
DEFAULT
$C3B2D00(CR)
EAN-13 2D Component =
Disable (2D component not required)
$C3B2D01(CR)
EAN-13 2D Component =
2D component must be decoded
ISSN
The following options apply to the ISSN symbology.
ISSN Enable/Disable
Enables/disables conversion of EAN/JAN13 Bookland labels starting with
977 to ISSN labels.
DEFAULT
$C3BIN00(CR)
ISSN = Disable
$C3BIN01(CR)
ISSN = Enable