RS-232 Parameters
Product Reference Guide
277
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label trans-
mission due to a retry condition. The selectable range is from 1 to 254
retries. A selection of 0 disables the count, and a selection of 255 specifies
unlimited retries.
To set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield three digits. For example:
0 = 000, 5 = 005, 20 = 020, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT ACK NAK RETRY COUNT SETTING.
5. Scan the appropriate three digits from the keypad in
, that represent the number which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See
for some examples of how to
set this feature.
Table 32. ACK NAK Retry Count Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Disable Retry
Count
3 Retries
54 Retries
Unlimited Retries
2
Pad with leading zero(es)
000
003
054
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK NAK RETRY COUNT SETTING
5
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘3’
‘0’, ‘5’ and ‘4’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание PowerScan PD9530
Страница 34: ...Enter Exit Programming Mode 24 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 56: ...Enter Exit Programming Mode 46 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 72: ...62 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 182: ...172 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 214: ...204 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 318: ...References 308 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 322: ...Message Formatting 312 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 360: ...Scancode Tables 350 PowerScan PD9530 PBT9500 PM9500 NOTES...