Enter/Exit Programming Mode
56
PowerScan™ PD9530/PBT9500/PM9500
Individually Set Label ID
This feature configures a Label ID individually for a single symbology. To
set, first define whether you want it as a prefix or suffix by scanning a label
below. Then turn to
Symbologies, starting on page 57
to select the symbology you want to set,
followed by up to 3 characters from the ASCII Chart at the back of this man-
ual. See "
Label ID: Set Individually Per Symbology" on page 291
for detailed
instructions on setting this feature.
Label ID Control
This option controls whether a Label ID is disabled, or sent as a prefix or
suffix for a given symbology type.
DEFAULT
$CIDCO00(CR)
Label ID Transmission = Disable
$CIDCO01(CR)
Label ID Transmission = Enable as Prefix
$CIDCO02(CR)
Label ID Transmission = Enable as Suffix
Содержание PowerScan PD9530
Страница 34: ...Enter Exit Programming Mode 24 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 56: ...Enter Exit Programming Mode 46 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 72: ...62 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 182: ...172 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 214: ...204 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 318: ...References 308 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 322: ...Message Formatting 312 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 360: ...Scancode Tables 350 PowerScan PD9530 PBT9500 PM9500 NOTES...