Enter/Exit Programming Mode
262
PowerScan™ PD9530/PBT9500/PM9500
Quantity/Code Send Mode
This feature defines the rules that will be used to send a QTY/CODE pair:
0. Code is transmitted with QTY field (and its predefined format) preced-
ing CODE field (and its predefined format)
1. Code is transmitted with CODE field (and its predefined format) preced-
ing QTY field (and its predefined format)
2. Code in CODE field is sent out for the number of times defined in the
QTY field
$CPWEH00\r
Qty precedes Code
DEFAULT
$CPWEH01\r
Code precedes Qty
$CPWEH02\r
Code transmitted Qty times
Quantity/Code Separator
This
feature
allows
the
insertion
of
a
separator
between
Qty/Code
pairs.
DEFAULT
$CPWQP00\r
No separator
$CPWQP
Set Qty/Code string separator
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the barcode at
left. Next scan 1 digit from
the range 1-8) representing the number of characters to
be used as separator.
Finally, define the separator string by reading the
desired characters from the ASCII table at the back of
this manual, expressed in hexadecimal form. End by
scanning the ENTER/EXIT bar code again.
Содержание PowerScan PD9530
Страница 34: ...Enter Exit Programming Mode 24 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 56: ...Enter Exit Programming Mode 46 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 72: ...62 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 182: ...172 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 214: ...204 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 318: ...References 308 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 322: ...Message Formatting 312 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 360: ...Scancode Tables 350 PowerScan PD9530 PBT9500 PM9500 NOTES...