Scanning Features
Product Reference Guide
297
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON
state once the state is entered. The range for this setting is from 1 to 255
seconds in 1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0
= 000, 5 = 005, 20 = 020, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT SCANNING ACTIVE TIME SETTING.
5. Scan the appropriate three digits from the keypad in
, that represent the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See
for some examples of how to
set this feature.
Table 42. Scanning Active Time Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
1 Second
90 Sec. (1.5 min.) 180 Sec. (3 min.)
255 Seconds (4.25
min.)
2
Pad leading zero(es)
001
090
180
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT SCANNING ACTIVE TIME SETTING
5
‘0’, ‘0’ and ‘1’
‘0’, ‘9’ and ‘0’
‘1’, ‘8’ and ‘0’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание PowerScan PD9530
Страница 34: ...Enter Exit Programming Mode 24 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 56: ...Enter Exit Programming Mode 46 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 72: ...62 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 182: ...172 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 214: ...204 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 318: ...References 308 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 322: ...Message Formatting 312 PowerScan PD9530 PBT9500 PM9500 NOTES...
Страница 360: ...Scancode Tables 350 PowerScan PD9530 PBT9500 PM9500 NOTES...