REFERENCES
Product Reference Guide
137
- Integrating Special Keys in Headers/Terminators -
1. the following example allows setting Special Key 1 (defined in example 1 above) as terminator:
enter configuration
one character terminator
special key 1
exit & save configuration
Read
Ì$+;Î
+
ÌEA111Î
+
Ì9CÄÎ
+
Ì$-?Î
2. the following example allows setting Special Key 2 (defined in example 2 above) as header:
enter configuration
one character header
special key 2
exit & save configuration
Read
Ì$+;Î
+
ÌEA01.Î
+
Ì9DÆÎ
+
Ì$-?Î
3. the following example allows setting Special Key 3 (defined in example 3 above) as header:
enter configuration
one character header
special key 3
exit & save configuration
Read
Ì$+;Î
+
ÌEA01.Î
+
Ì9EÈÎ
+
Ì$-?Î
4. the following example allows setting Special Key 4 (defined in example 4 above) and ENTER character as
terminators:
enter configuration
two character terminator
special key 4
ASCII characters corresponding to
the HEX value for character ENTER
exit & save configuration
Read
Ì$+;Î
+
ÌEA125Î
+
Ì9FÊÎ
+
83
+
Ì$-?Î
5.3.3 Address
Stamping
It is possible to include the reader address in the message sent to the host. The Reader Address Stamping and the Cradle
Address Stamping parameters consist of 12 hex characters. For message output format, refer to chapter 6.
5.3.4 Address
Delimiter
The Address Delimiter allows a character to be included to separate the reader Address stamping field from the next field
in the message. Any character can be included in the hexadecimal range from 00 to FE.
For message output format, refer to chapter 6.
5.3.5
Time Stamping Format
The Time Stamping parameter sets the format for hour and date information. It consists of 1 or 2 groups of numbers, each
one made up of 6 decimal digits.
For example, setting the Hour/Minutes/Seconds/Month/Day/Year format, the information
17:03:16
on
June 12, 2002
will be
formatted as 170316061202.
5.3.6
Time Stamping Delimiter
The Time Stamping Delimiter allows a character to be included to separate the Time Stamping field from the next field in
the message. Any character can be included in the hexadecimal range from 00 to FE.
Содержание PowerScan BT8300 Family
Страница 186: ...Enter Configuration Exit and Save Configuration HEX NUMERIC KEYPAD 180 PowerScan BT8300 Family 0 1 2 3 4 5 6 7 8 9...
Страница 187: ...Enter Configuration Exit and Save Configuration HEX NUMERIC KEYPAD Product Reference Guide 181 A B C D E F G H I J K L M...
Страница 188: ...Enter Configuration Exit and Save Configuration HEX NUMERIC KEYPAD 182 PowerScan BT8300 Family N O P Q R S T U V W X Y Z...
Страница 189: ...Enter Configuration Exit and Save Configuration HEX NUMERIC KEYPAD Product Reference Guide 183 a b c d e f g h i j k l m...
Страница 190: ...Enter Configuration Exit and Save Configuration HEX NUMERIC KEYPAD 184 PowerScan BT8300 Family n o p q r s t u v w x y z...
Страница 191: ......