E-GENIUS
121
4
4.5.6 Modify Settings | Global Settings | Fieldbus
Use the
Fieldbus
window to configure Fieldbus type communication between the scanner
and Host, or, in a multi-sided layout, between several scanners and a Host.
To edit the Fieldbus settings:
1. In the tree menu under Modify Settings, navigate to
Global Settings | Fieldbus
.
The Fieldbus window opens.
2. Enter the appropriate information in the form as described below:
Field Name
Action/Definition
Type
Fieldbus type is displayed. When using the CBX510 with Fieldbus modules,
select the correct Fieldbus Type. For SC5000, this option is preset and read-only
based on the controller model used.
Data Tx
Select Enable or Disable from the drop-down list. If enabled, the fieldbus port is
used by the scanner to transmit data and/or messages.
Heartbeat
Select Disable, Enable Unconditioned, or Enable Conditioned from the drop-
down list.
This parameter is available when the Data TX parameter is checked. It
enables/disables the transmission of the Heartbeat message signaling that the
device is still active.
Disable: The Heartbeat message is not transmitted
Enable Unconditioned: The Heartbeat message is always transmitted, even if
communication is still active
Enable Conditioned: The Heartbeat message is transmitted only when there is
no communication
Heartbeat Settings
Heartbeat
Timeout
Enter a time value in seconds to define the amount of time between two message
transmissions. If the input timeout expires and no transmission has occurred, the
Heartbeat message will be transmitted.
Содержание DS8110
Страница 1: ...REFERENCE MANUAL DS8110 Barcode Scanner ...
Страница 40: ...DS8110 REFERENCE MANUAL 28 3 Figure 25 DS8110 Array Tunnel to SC5000 alternate with CBX ...
Страница 49: ...ELECTRICAL INSTALLATION 37 3 3 11 1 Photoelectric Sensor NPN Figure 32 Photoelectric Sensor Wiring NPN Output ...
Страница 50: ...DS8110 REFERENCE MANUAL 38 3 3 11 2 Photoelectric Sensor PNP Figure 33 Photoelectric Sensor Wiring PNP Output ...
Страница 52: ...DS8110 REFERENCE MANUAL 40 3 Figure 35 OEK 4 95B082050 Encoder Tachometer Wiring NPN Output ...
Страница 54: ...DS8110 REFERENCE MANUAL 42 3 Figure 37 OEK 4 95B082050 Encoder Tachometer Wiring PNP Output ...
Страница 56: ...DS8110 REFERENCE MANUAL 44 3 3 13 2 Powered Outputs Figure 40 Powered Outputs NPN PNP ...
Страница 248: ...DS8110 REFERENCE MANUAL 236 5 DS8110 2100 STANDARD RESOLUTION Figure 68 Reading Diagram DS8110 2100 Combined ...
Страница 249: ...BARCODE SCANNING FEATURES 237 5 Figure 69 Reading Diagram DS8110 2100 0 33mm 13mil ...
Страница 250: ...DS8110 REFERENCE MANUAL 238 5 Figure 70 Read Chart DS8110 2100 0 38mm 15mil ...
Страница 251: ...BARCODE SCANNING FEATURES 239 5 Figure 71 Read Chart DS8110 2100 0 50mm 20mil ...
Страница 252: ...DS8110 REFERENCE MANUAL 240 5 DS8110 2200 HIGH RESOLUTION Figure 72 Reading Diagram DS8110 2200 Model 2 Combined ...
Страница 253: ...BARCODE SCANNING FEATURES 241 5 Figure 73 Reading Diagram DS8110 2200 0 25mm 10mil ...
Страница 254: ...DS8110 REFERENCE MANUAL 242 5 Figure 74 Reading Diagram DS8110 2200 0 30mm 12mil ...
Страница 255: ...BARCODE SCANNING FEATURES 243 5 Figure 75 Reading Diagram DS8110 2200 0 33mm 13mil ...
Страница 256: ...DS8110 REFERENCE MANUAL 244 5 Figure 76 Reading Diagram DS8110 2200 0 38mm 15mil ...
Страница 257: ...BARCODE SCANNING FEATURES 245 5 DS8110 2300 LOW RESOLUTION Figure 77 Reading Diagram DS8110 2300 0 50mm 20mil ...
Страница 281: ......
Страница 282: ......