2.2 - Installation
2.2 OPENING THE SCANNER
DS6100 scanners can be completely configured through software using one
of the three methods listed in the "Guide to Installation" at the beginning of
this manual. The scanner therefore can be installed without the necessity of
opening it to configure hardware switches.
To determine if it is necessary to open the scanner for hardware
configuration of your application, the default hardware settings are listed
below:
•
Multidrop address selection = address 0 (software configurable)
•
Inputs
=
NPN
To change the default settings, before installing the DS6100, refer to the
procedures in the following paragraphs:
•
setting the multidrop address (hardware configuration) see par. 2.2.1
•
select the input type see par. 2.2.2
WARNING
Before unscrewing the connector or cable
panel of the DS6100, make sure the power
supply cable is disconnected to avoid shock
or harm to the operator.
Refer to the following instructions and refer to Figure 2.2 when opening the
reader:
1. The part of the device to be opened is the connector or cable panel on the
side of the scanner.
2. Unscrew the four screws to open the scanner.
!
Содержание DS6100