DS6100
DATALOGIC
2.32 - Installation
or RS485 full-duplex for Host connections or RS485 half-duplex for
Multiplexer connections.
For the Slave scanners the Multidrop Address Selection can be made using
the DIP switch. The addresses must be consecutive and different from zero
for hardware configuration, or be selected in software, (in this case the DIP
switch address must be zero for each Slave). See "Multidrop Address
Selection" in par. 2.2.1.
NOTE
The main serial port of the Slave scanners can be used
for configuration. The termination resistors of the RS485
bus must not be installed.
Single P.S.
The P.S. signal is unique to the system; there is a single reading phase and
a single message from the Master scanner to the Host.
The On-Line
operating mode is used for this layout.
DS6100 Master
2
Slave
DS6100
1
3
Presence sensor
3
Auxiliary serial interface: RS485 HD
2
Main serial interface
1
DS6100 Slave
HOST
PC or PLC
RS232
RS485 full-duplex
MULTIPLEXER
MX4000
RS485 half-duplex
Figure 2.37 - Master-slave Single P.S. layout