2.24 - Installation
PS2 can be used as the stop signal for the reading phase.
All inputs are optocoupled and driven by a constant current generator; the
command signal is filtered through an anti-disturbance circuit which
generates a delay of about 5 ms for PS1 and PS2 and 500
µ
s for ENC.
For PS1 and PS2, the NPN or PNP connection must be made by setting the
jumper as shown in par. 2.2.2.
PRESENCE SENSOR
PS1+/PS2+
D/C
DS6100
PSIN
+ 5V
VS
A
Vext
B
GND
V
Figure 2.24 - Presence sensor input PNP command
PRESENCE SENSOR
DS6100
PSIN
Vext
PS1-/PS2-
D/C
+ 5V
VS
A
V
B
GND
Figure 2.25 - Presence sensor input NPN command
ENCODER
Signal
ENC+
ENC-
E
F
+ 5V
VS
A
B
GND
DS6100
V
Ground
Figure 2.26 - Encoder NPN input command using DS6100 power