DATALOGIC
DS6100
Installation - 2.21
20 mA Current Loop (INT-26 Accessory Only)
When the INT-26 accessory board is installed, the DS6100 is equipped with
a 20 mA current loop interface. The INT-26 board supports both active and
passive type connections.
The following pins of the 19-pin output connector are used for the connections:
Pin
Name
Function
U
DRVIN
input current generator
V
DRVOUT
output current generator
N
CLGND
generator reference
R
CLOUT+
current Loop
P
CLOUT-
current Loop output -
T
CLIN+
current Loop input +
S
CLIN-
current Loop input -
CLOUT-
CLOUT+
CLIN-
CLIN+
CLGND
DRVIN
DRVOUT
DS6100
USER INTERFACE
MAX. 300 METERS
S
C.L. IN-
T
C.L. IN+
P
C.L. OUT-
R
C.L. OUT+
N
CLGND
SGND
U
DRVIN
V
DRVOUT
I = 20 mA
I = 20 mA
GND
Figure 2.20 - 20 mA C.L. active connections