2.30 - Installation
Figure 2.34 - Focus regulation
2.8 TYPICAL
LAYOUTS
The following typical layouts refer to system hardware configurations. Dotted
lines in the figures refer to optional hardware configurations within the
particular layout.
These layouts also require the correct setup of the software configuration
parameters. See the WinHost Help On Line.
2.8.1 Standard (Point-to-Point)
Using a point-to-point layout, the data is transmitted on the Auxiliary interface
as well as on the Main interface. The Main interface can be selected for
RS232, RS485 full-duplex or if INT-26 is installed, 20 mA C.L.
communications. RS485 half-duplex communications cannot be used on
either interface in this layout. Programming in Host Mode can be
accomplished through the Main interface or Auxiliary interface.
1
Host
2
Terminal
Main serial interface
Auxiliary serial interface
Presence sensor (for On-Line mode)
2
3
1
DS6100
3
Figure 2.35 - Point-to-Point layout
NOTE
The focus adjustment screw
is positioned by default at the
value 2.