2.26 - Installation
The voltage available on the input connector, between pins A and B, is
physically the same as used to power the scanner.
The electrical features of these inputs are:
Maximum voltage
30 V
Maximum current
25 mA
2.5.5 Outputs
Apart from the main and auxiliary interface outputs on the 19-pin circular
connector (Figure B,
12
), there are also indicator and power supply outputs
for external devices.
Pin
Name
Function
A
GND
power for external devices -
B
VS
power for external d
C
NO READ-
no read output
D
NO READ+
no read output
E
RIGHT-
right code output
F
RIGHT+
right code output
G
SPS-
slave presence sensor
H
SPS+
slave presence sensor
A D.C. output voltage, the same as that powering the DS6100, is present
between pins A and B. This may be used to power external devices: electrical
isolation between the scanner and external devices is lost in this case.
The NO READ output activates when a code signalled by the presence
sensor is not decoded.
The RIGHT output is used to signal the presence of a right code, thus a good
decode condition.
The NO READ and RIGHT outputs are all level or pulse programmable: a 50
ms pulse is generated in the second case. Further programming information
is supplied in the WinHost Help File. These outputs are created using
optoisolated Darlington drivers and supply both the collector and emitter in
output, allowing both loads referenced to ground and to the power supply to
be driven.
Содержание DS6100
Страница 1: ...DS6100 Installation Manual ...
Страница 2: ...DS6100 INSTALLATION MANUAL ...
Страница 11: ...x This page is intentionally left blank ...
Страница 23: ...DS6100 DATALOGIC 2 8 Installation mm in Figure 2 6 DS6100 overall dimensions junction box model ...
Страница 57: ...DS6100 DATALOGIC 4 2 Maintenance This page is intentionally left blank ...