background image

DS5100 REFERENCE MANUAL 

 

48 

 

 

 

 

 
 
Connector block rotates to 90° position. 
 

Figure 20 

– DS5100 OM Profinet Model Overall Dimensions 

 

 

 

Содержание DS5100

Страница 1: ......

Страница 2: ...express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Geni...

Страница 3: ...ation 18 2 INTRODUCTION 19 2 1 Product Description 19 2 1 1 Indicators 20 2 2 ID NET 20 2 2 1 How To Setup Configure the Scanner Network 22 2 3 X PRESS Human Machine Interface 23 2 3 1 Diagnostic Indi...

Страница 4: ...Station Layout with Dual Port Scanners 77 5 5 EBC Networks 78 5 6 ID NET Synchronized Networks 83 5 7 ID NET Multidata Networks 88 5 8 Pass Through 89 5 9 Other Layouts 89 6 READING FEATURES 90 6 1 A...

Страница 5: ...s 136 User Interface Serial Host 137 B ALTERNATIVE CONNECTIONS FOR ETHERNET MODELS 138 Power COM and I O Connector 138 On Board Ethernet Connector 139 ID NET Network Termination 139 Inputs 139 Outputs...

Страница 6: ...w datalogic com and click on the SUPPORT Unattended Scanning Systems category link From this page you can select your product model from the dropdown list which gives you access to Downloads including...

Страница 7: ...plicable requirements of IEC 60825 1 and complies with 21 CFR 1040 10 except for deviations pursuant to Laser Notice N 50 date June 24 2007 The scanner is classified as a Class 2 laser product accordi...

Страница 8: ...aximum level of the laser diode 60 mW at 630 to 680 nm Warning and Device Class Labels Produit s conforme selon 21CFR 1040 10 sauf des d rogations relatives la Laser Notice N 50 date Juin 24 2007 Dans...

Страница 9: ...ce of the product with essential requirements listed in the applicable European directive Since the directives and applicable standards are subject to continuous updates and since Datalogic promptly a...

Страница 10: ...however it is also a precision product and therefore before and during installation it must be handled correctly to avoid damage avoid that the scanners hit one another causing damage They should be h...

Страница 11: ...xi do not weld the scanner into position which can cause electrostatic heat or output window damage do not spray paint near the scanner which can cause output window damage...

Страница 12: ...nd Device Class Labels 7 Indicator LEDs 2 Power Serial Interfaces I O Cable 8 Network LEDs with 25 pin D sub connector 9 Power On LED 4 Laser Beam Output Window 10 Focus Adjustment Screw 5 Mounting Ho...

Страница 13: ...els 7 Indicator LEDs 2 Power Serial Interfaces I O Connector 8 Network LEDs 3 Ethernet Connector 9 Power On LED 4 Laser Beam Output Window 10 Focus Adjustment Screw 5 Mounting Holes 7 11 X PRESS Push...

Страница 14: ...ndicator LEDs 2 Power Trigger Input Connector 8 Network LEDs 3 Profinet IO EBC Network Connectors 9 Power On LED 4 Laser Beam Output Window 10 Focus Adjustment Screw 5 Mounting Holes 7 11 X PRESS Push...

Страница 15: ...e Class Labels 7 Indicator LEDs 2 Power Serial Interfaces I O Cable 8 Network LEDs with 25 pin D sub connector 9 Power On LED 4 Laser Beam Output Window 10 Focus Adjustment Screw 5 Mounting Holes 7 11...

Страница 16: ...2 Power Serial Interfaces I O Connector 8 Network LEDs 3 Ethernet Connector 9 Power On LED 4 Laser Beam Output Window w heater 10 Focus Adjustment Screw 5 Mounting Holes 7 11 X PRESS Push Button 6 Di...

Страница 17: ...ut the data is transmitted to the Host on the main serial interface In Local Echo communication mode the RS232 auxiliary interface can be used to transmit data independently from the main interface se...

Страница 18: ...Interface I1B External Trigger B polarity insensitive TX Auxiliary Interface TX V Power Reference External Trigger RX Auxiliary Interface RX V Power Source Inputs SGND Auxiliary Interface Reference I2...

Страница 19: ...hown in the figures below Figure 3 Positioning with Mounting Bracket 2 When mounting the scanner take into consideration these three ideal label position angles Skew 15 to 30 Tilt 0 and Pitch 0 Assure...

Страница 20: ...OM take into consideration these three ideal label position angles Skew 15 to 30 Tilt 0 and Pitch 0 The Skew angle refers to the most inclined or external raster line so that all other raster lines a...

Страница 21: ...focus is in the Unlocked position The alternating message on the display shows the mechanical Focus Position as well as the message Please Lock Focus on the scanner display 2 Using a screwdriver turn...

Страница 22: ...icator LEDs are illustrated in the following table LED Color Description READY Green Indicates the device is ready to operate For Subzero models this LED blinks during the warm up phase GOOD Green Con...

Страница 23: ...ferent barcodes the LEARN LED returns to the blinking state for the next code If more than one barcode is detected in the scan line the Multi Label mode is enabled refer to the 5K Family Software Conf...

Страница 24: ...timal setup of the reading parameters for that specific barcode Figure 8 X PRESS Interface Auto Setup Function The procedure is as follows A place the desired barcode on the scanline B enter the AutoS...

Страница 25: ...S LOCK LED is on 2 Release the button to enter the Focus Lock function Once entered the scanner automatically performs the Lock saving or Unlock procedure depending on the previous state of the Locked...

Страница 26: ...et IO message appears on the display indicating the scanner has been set and saved The scanner will restart at the end of the process NOTE To reset the scanner to its default Profinet interface settin...

Страница 27: ...ile Select Install Genius and follow the installation procedure This configuration procedure assumes scanner connection to a CBX100 500 Genius running on a laptop computer is connected to the scanner...

Страница 28: ...S5100 REFERENCE MANUAL 12 1 1 Select the Create a new configuration button You will be guided through the configuration being asked to define the following parameters a Barcode selection and definitio...

Страница 29: ...RAPID CONFIGURATION 13 1 b Operating mode selection and definition a Digital Inputs configuration...

Страница 30: ...DS5100 REFERENCE MANUAL 14 1 b Digital Outputs configuration c Hardware interface selection...

Страница 31: ...ode does not require connection to an external Presence Sensor When working in this mode the reader is continuously scanning while the reading phase is activated each time a barcode enters the reader...

Страница 32: ...guration as follows Saving the configuration to disk Switching to Advanced mode Sending the configuration to the scanner 3 After sending the configuration to the scanner you have completed the configu...

Страница 33: ...Chart Code 128 1 Enter the Test mode function by holding the X PRESS push button pressed until the TEST LED is on 2 Release the button to enter the Test mode function Once entered the Bar Graph on th...

Страница 34: ...st computer using the Host Mode programming procedure by commands via the serial interface See the Host Mode Programming manual on the downloadable Genius mini DVD zip file Alternative Layouts The ID...

Страница 35: ...in features are listed below Medium Long Range Linear and Oscillating Mirror models user selectable focus for high application flexibility ID NET and EBC Ethernet Bus Connections Embedded PROFINET IO...

Страница 36: ...en in the absence of data transmission because of polling activity on the Fieldbus network During the reader startup reset or restart phase all the LEDs blink for one second PWR blue This LED indicate...

Страница 37: ...re typically located far away from each other and they use a dedicated presence sensor At the end of each reading phase each scanner transmits its own data message to the host Thanks to ID NET data co...

Страница 38: ...figuration to the Local Device Master choose Yes 4 Then run the NET AUTOSET procedure from the Icon in the Devices Area Genius sets all slave scanners according to the Master Role Synchronized or Mult...

Страница 39: ...m all The colors and meaning of the five LEDs when in the one of the operating modes On Line Automatic or Continuous are illustrated in par 2 1 1 NOTE Except for the Focus Lock Unlock function the X P...

Страница 40: ...ce button is pressed the cycle of LEDs activation is as follows Release button to Exit Release button to enter Test Mode Release button to enter AutoLearn Release button to enter AutoSetup Release but...

Страница 41: ...tically configured in scanner memory AutoSetup Function Once entered if a barcode label is positioned in front of the scanline the scanner automatically performs the optimal setup of the reading param...

Страница 42: ...you can perform this procedure by holding the X PRESS push button pressed while powering up the scanner and waiting for all LEDs to blink simultaneously three times before releasing the push button T...

Страница 43: ...ontroller QLM Series Gateways NOTE Before executing a Backup on a BM100 backup module make sure the Write Protection switch is set to Unlocked If BM100 and BM2x0 are both installed B R is automaticall...

Страница 44: ...re the new scanner has been previously set to default 3 Run the Restore procedure by pressing the Restore Button see Restore procedure NOTE If the Automatic Scanner Replacement parameter is enabled th...

Страница 45: ...rmed Other Configuration 1 Connect to the scanner and properly configure it according to your application needs 2 Enable the Automatic Scanner Replacement parameter then Send the configuration to the...

Страница 46: ...can be enabled disabled in Genius The display language for messages can be selected in Genius The currently supported languages are English default French German Italian Japanese 2 6 1 Display Message...

Страница 47: ...tic Alarms A l e r t F o c u s E x p X X X c m X X X i n X expected focus distance in cm and inches A l e r t M o t o r S p e e d X X X X Y Y Y Y X expected speed Y actual speed Generic Alarms A l e r...

Страница 48: ...mber of scans on the code S Quality Counters value max 100 Code Reconstruction W number of scans on the code max 255 S number of decodes max 255 on the digit in the code which was decoded the least nu...

Страница 49: ...M00 ID NET Network Master Sxx ID NET Network Slave address or EBC Slave address Null string Alone no network Focus Locked F o c u s L o c k e d a t F Z Z Z c m Y Y Y i n X device serial number Z focus...

Страница 50: ...ilable For a complete list of combinations see the Models tab on the Product page of the website Communication Interface 2 SER RS232 RS485main RS232aux 3 ETH Built in Ethernet PNET 1 port Profinet I O...

Страница 51: ...more than 15 Skew This avoids the direct reflection of the laser light emitted by the reader 0 15 35 code surface 5 Figure 5 Oscillating Mirror Skew Angle Otherwise the scanner can be mounted at an a...

Страница 52: ...ensation build up from negatively affecting the reading results Upon power up in a subzero environment the scanner waits until these internal components are heated to within their operating temperatur...

Страница 53: ...iscovery utility available in the Options Communications tab NOTE This feature only works for the built in interfaces Ethernet or Profinet IO Discovery Procedure 1 Select the desired device by compari...

Страница 54: ...DS5100 REFERENCE MANUAL 38 2 3 Click the Apply button The device will be re discovered You should now see the device displayed with the newly assigned IP address...

Страница 55: ...r only for DS5100 XX00 Linear readers 93ACC1785 GFC 400 only for DS5100 XX00 Linear readers 93ACC1867 Brackets BK 4000 L Shape Bracket 93ACC1837 BK 4001 U Shape Bracket 93ACC1838 Connection Boxes CBX1...

Страница 56: ...750001 SC5000 1100 Profibus System Controller 935750002 SC5000 1200 Profinet System Controller 935750003 Cables CAB DS01 S M12 IP67 Cable To CBX or QL 1M 93A050058 CAB DS03 S M12 IP67 Cable To CBX or...

Страница 57: ...G 100 K01 POWER SUPPLY 60W KIT EU with M12 connector for Profinet models 93ACC0059 PG 100 K02 POWER SUPPLY 60W KIT UK with M12 connector for Profinet models 93ACC0060 PG 100 K03 POWER SUPPLY 60W KIT U...

Страница 58: ...the DS5100 reader and all the parts supplied with the equipment are present and intact when opening the packaging the list of parts includes DS5100 reader DS5100 Quick Guide Barcode Test Chart Grade A...

Страница 59: ...r mechanical fixture to the L shaped mounting bracket There are also three screw holes M5 x 5mm depth for fixture to the U shaped mounting bracket The following diagrams give the overall dimensions of...

Страница 60: ...DS5100 REFERENCE MANUAL 44 3 Connector block rotates to 90 position Figure 16 DS5100 Standard Ethernet Model Overall Dimensions mm in...

Страница 61: ...MECHANICAL INSTALLATION 45 3 Connector block rotates to 90 position Figure 17 DS5100 Standard Profinet Model Overall Dimensions mm in...

Страница 62: ...DS5100 REFERENCE MANUAL 46 3 Figure 18 DS5100 OM Serial Model Overall Dimensions...

Страница 63: ...MECHANICAL INSTALLATION 47 3 Connector block rotates to 90 position Figure 19 DS5100 OM Ethernet Model Overall Dimensions...

Страница 64: ...DS5100 REFERENCE MANUAL 48 3 Connector block rotates to 90 position Figure 20 DS5100 OM Profinet Model Overall Dimensions...

Страница 65: ...21 L Shape Mounting Bracket Overall Dimensions Figure 22 U Shape Mounting Bracket Overall Dimensions 55 2 17 10 0 39 70 2 76 80 3 15 4 2 0 17 N 4 4 2 0 17 N 4 3 0 8 1 0 32 N 2 8 1 0 32 N 6 70 2 76 12...

Страница 66: ...5100 Using the DS5100 mounting bracket you can quickly and easily obtain standard mounting positions i e 15 Skew angles for the reader as shown in the following figures Figure 23 Positioning with L Sh...

Страница 67: ...MECHANICAL INSTALLATION 51 3 Figure 24 Positioning with U Shape Mounting Bracket Tilt alignment marks Skew 0 45 45 15 15...

Страница 68: ...DS5100 REFERENCE MANUAL 52 3 Figure 25 DS5100 OM Positioning with U Shape Mounting Bracket Tilt alignment marks Skew 0 45 45 15 15...

Страница 69: ...g Window CAUTION Avoid any contact with the deflection mirror mirrored rotor the lenses or other optical components otherwise the performance of the reader will be reduced Clean the deflection mirror...

Страница 70: ...angle is represented by the value S in Figure 29 Position the reader to assure at least 15 for the Skew angle This avoids the direct reflection of the laser light emitted by the DS5100 Figure 29 DS51...

Страница 71: ...MECHANICAL INSTALLATION 55 3 The Pitch angle is represented by the value P in Figure 31 Position the reader in order to minimize the Pitch angle Figure 31 DS5100 Pitch Angle P P...

Страница 72: ...ls of the connector pins and relative connections are indicated in Appendix C The table below gives the pinout of the CBX100 500 terminal block connectors Use this pinout when the DS5100 reader is con...

Страница 73: ...ct the device CHASSIS to earth ground Earth by setting the appropriate jumper in the CBX connection box See the CBX Installation Manual for details 4 2 MAIN SERIAL INTERFACE CAUTION Do not connect to...

Страница 74: ...The overall maximum cable length must be less than 15 m 49 2 ft SGND RXD TXD CTS RTS USER INTERFACE SGND TX RX RTS CTS SCANNER Figure 33 RS232 Main Interface Connections Using Hardware Handshaking Th...

Страница 75: ...nments The CBX pinout follows CBX100 500 Function TX RS485 Transmit Data RX RS485 Receive Data TX RS485 Transmit Data RX RS485 Receive Data SGND Signal Ground RX485 TX485 SGND RX485 TX485 USER INTERFA...

Страница 76: ...x cable length depends on the baudrate used see the Baudrate Table below For Common Power Connections use only 2 wires ID and ID DC Voltage Power cable Vdc GND should be handled as a signal cable i e...

Страница 77: ...between the Trigger activation and the beginning of data transmission to the Host Max ID NET Response Time 240 220 200 180 160 140 120 100 80 60 40 20 0 Response Time ms Number of Nodes 500 kbps 250...

Страница 78: ...DS5100 REFERENCE MANUAL 62 4 Figure 38 ID NET Network Connections with isolated power blocks...

Страница 79: ...ELECTRICAL INSTALLATION 63 4 Figure 39 ID NET Network Connections with Common Power Branch Network...

Страница 80: ...DS5100 REFERENCE MANUAL 64 4 Figure 40 ID NET Network Connections with Common Power Star Network...

Страница 81: ...tility program or Genius based Host Mode Programming provided on the downloadable Genius mini DVD zip file The 9 pin female Auxiliary Interface connector inside the CBX is the preferred connector for...

Страница 82: ...ion V Power Source External Trigger I1A External Trigger A polarity insensitive I1B External Trigger B polarity insensitive V Power Reference External Trigger The External Trigger input is used in the...

Страница 83: ...r Using Scanner Power EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER Pulled down to External Input Device Reference Input Signal PNP Photocell Figure 45 PNP External Trigger Using External Po...

Страница 84: ...S USING SCANNER POWER Power to Input Device Input Input Device Signal Reference Input Device PNP Input 2 Using Scanner Power Power to Input Input Device Signal Input Device Reference Input Device NPN...

Страница 85: ...er Parameters in the 5K Family Software Configuration Parameter Guide Help file 4 6 OUTPUTS Two general purpose outputs are available CAUTION For Ethernet models when Outputs 1 and 2 are connected thr...

Страница 86: ...e Vdc GND spring clamps is available directly to the Output Device on the V V spring clamps and does not pass through the Power Switch ON OFF inside the CBX Disconnect the power supply when working in...

Страница 87: ...erface types please refer to their own manual RS232 PC side connections 1 5 9 6 9 pin male connector 13 25 14 1 25 pin male connector Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CT...

Страница 88: ...transmitted to the Host on the main serial interface A Genius based Host Mode programming can be accomplished either through the main interface or the Auxiliary interface In Local Echo communication...

Страница 89: ...nius configuration program or Genius based Host Mode programming In Local Echo communication mode data is transmitted on the RS232 auxiliary interface independently from the Fieldbus interface selecti...

Страница 90: ...g a Local Area Network LAN one or more DS5100 x3xx model scanners can be connected to the network by using CAB ETH M0x cables In the example below Power and an External Trigger are brought to each sca...

Страница 91: ...e Port Scanners x3xx models One or more DS5100 x3xx model scanners can be connected to the network by using CAB ETH M0x cables connected to a Certified PROFINET IO Switch or PLC Every scanner must hav...

Страница 92: ...in Help On Line For a Single Station layout each scanner simultaneously receives the Trigger signal Trigger Input from presence sensor Input from Fieldbus Host or Serial Start Stop from Fieldbus Host...

Страница 93: ...in Help On Line For a Multi Station layout each scanner independently receives the Trigger signal Trigger Input from presence sensor Input from Fieldbus Host or Serial Start Stop from Fieldbus Host an...

Страница 94: ...2 M12 cables Power connections can be made using the CS A1 02 or AS I accessory power cables to the power source The Trigger signal is sent through the SC5000 to all the readers simultaneously and eac...

Страница 95: ...ctrically connect the DS5100 scanner in the application 2 To set the DS5100 scanner as an EBC Slave follow the EBC network selection procedure described in step 4 X PRESS Configuration 3 Run Discovery...

Страница 96: ...UAL 80 5 4 Give a descriptive name to the DS5100 scanner typically scanner position and then press the Update All button 5 From the SC5000 Utilities menu launch Genius 6 Run the Get command to open th...

Страница 97: ...TYPICAL LAYOUTS 81 5 7 Double click on the DS5100 scanner to configure it...

Страница 98: ...erating mode is only available for dual port long range models working in EBC DS5100 24xx 8 Save the configuration to the DS5100 scanner in Genius 9 Save the entire EBC network slave scanners SC5000 c...

Страница 99: ...the External Trigger signal is unique to the system there is a single reading phase and a single message from the master scanner to the Host computer It is not necessary to bring the External Trigger...

Страница 100: ...Layout DS5100 Master with QL500 DS5100 Slaves with QL100 Host QL100 PS Power Ethernet Interface CBL 1490 ID NET Terminator The ID NET network must be terminated inserting an ID NET terminator into the...

Страница 101: ...ner internal CBX500 9 pin connector using the Genius configuration program or Genius based Host Mode programming Configuration can also be accomplished in Genius directly through the Ethernet network...

Страница 102: ...CBX500 connection box System configuration can be accomplished through the Auxiliary interface of the Master scanner internal CBX500 9 pin connector using the Genius configuration program or Genius b...

Страница 103: ...S5100 Slaves with QL100s Input Power Profibus Interface External Trigger for On Line Mode External Digital I O Devices Aux port for Reader Configuration ID NET Network ID NET Terminator NOTE The ID NE...

Страница 104: ...ost Figure 67 ID NET Multidata with Fieldbus Host Terminal Main Serial Interface RS232 or RS485 Auxiliary Serial Interface Local Echo RS232 External Trigger for On Line Mode ID NET up to 32 devices ma...

Страница 105: ...st When On Line Operating mode is used the scanner is activated by an External Trigger photoelectric sensor when the object enters its reading zone Figure 68 Pass Through On ID NET Layout NOTE The Mas...

Страница 106: ...partial scans on the label obtained using the motion of the label itself the scanner is able to reconstruct the barcode A typical set of partial scans is shown in the figure below Code Direction Figur...

Страница 107: ...e maximum tilt angle maximum under which the code reconstruction process is still possible Laser Beam tilt angle 0 to max Figure 72 Tilt Angle The decoder will be able to read the label with a tilt an...

Страница 108: ...o 3 1 Table 1 Code 39 Minimum Code Height for ACR4 Reading mm 45 max 30 max Conveyor Speed m s 0 5 1 1 5 2 2 5 3 0 5 1 1 5 2 2 5 3 Code Resolution mm 0 25 11 14 16 19 22 25 8 10 12 14 16 19 0 30 12 15...

Страница 109: ...nimum Code Height for ACR4 Reading mm 45 max 30 max Conveyor Speed m s 0 5 1 1 5 2 2 5 3 0 5 1 1 5 2 2 5 3 Code Resolution mm 0 25 9 12 15 18 21 23 7 9 11 13 16 18 0 30 10 13 16 19 22 24 7 9 12 14 16...

Страница 110: ...3 24 Ratio 3 1 Table 6 Code 39 Minimum Code Height for ACR4 Reading mm 45 max 30 max Conveyor Speed m s 0 5 1 1 5 2 2 5 3 0 5 1 1 5 2 2 5 3 Code Resolution mm 0 25 9 9 11 12 14 15 6 7 8 9 10 11 0 30 1...

Страница 111: ...nimum Code Height for ACR4 Reading mm 45 max 30 max Conveyor Speed m s 0 5 1 1 5 2 2 5 3 0 5 1 1 5 2 2 5 3 Code Resolution mm 0 25 7 8 9 11 12 14 5 6 7 8 9 11 0 30 8 9 10 11 13 14 6 6 7 9 10 11 0 33 9...

Страница 112: ...o ensure a successful read 6 2 1 Step Ladder Mode If scanning is perpendicular to the code motion direction Figure 74 the number of effective scans performed by the reader is given by the following fo...

Страница 113: ...ective scans FW reading field width in mm LW label width in mm LS label movement speed in mm s SS scans per second Figure 75 Picket Fence Scanning Mode For example for a 60 mm wide code moving in a po...

Страница 114: ...20 mils codes F 45 Near 0 25 mm 10 mils 30 cm 11 8 in 72 cm 28 3 in F 65 Med 0 30 mm 12 mils 45 cm 17 7 in 110 cm 43 3 in F 75 Far 0 38 mm 15 mils 58 cm 22 8 in 140 cm 55 1 in 1x20 OM Medium Range Mod...

Страница 115: ...es For Standard and OM models these diagrams are taken on various resolution sample codes at a 25 C ambient temperature and depend on the conditions listed under each diagram Subzero model diagrams ar...

Страница 116: ...r beam output window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading pe...

Страница 117: ...are Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately...

Страница 118: ...Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately 10...

Страница 119: ...re Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately...

Страница 120: ...ettings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately 10 R...

Страница 121: ...put window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance...

Страница 122: ...ardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approxima...

Страница 123: ...tings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately 10 Rea...

Страница 124: ...dware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximate...

Страница 125: ...ings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately 10 Read...

Страница 126: ...the center of the laser beam output window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 45 Software Parameters Reading Mode Linear Reading Dist...

Страница 127: ...beam output window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 45 Software Parameters Reading Mode Linear Reading Distance Horizontal Reading W...

Страница 128: ...eam output window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 45 Software Parameters Reading Mode Linear Reading Distance Horizontal Reading Wi...

Страница 129: ...window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 45 Software Parameters Reading Mode Linear Reading Distance Horizontal Reading Width 8 12 16...

Страница 130: ...output window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performa...

Страница 131: ...dware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximate...

Страница 132: ...Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately 10...

Страница 133: ...re Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately...

Страница 134: ...ettings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately 10 R...

Страница 135: ...m output window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading perform...

Страница 136: ...Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approxim...

Страница 137: ...ttings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately 10 Re...

Страница 138: ...dware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximate...

Страница 139: ...ings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 0 Software Parameters Reading Mode Linear For Tilt angles of 45 the reading performance is reduced by approximately 10 Read...

Страница 140: ...0 0 is the center of the laser beam output window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 45 Software Parameters Reading Mode Linear Readin...

Страница 141: ...beam output window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 45 Software Parameters Reading Mode Linear Reading Distance Horizontal Reading W...

Страница 142: ...eam output window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 45 Software Parameters Reading Mode Linear Reading Distance Horizontal Reading Wi...

Страница 143: ...window CONDITIONS Hardware Settings Code Symbology Code 128 PCS 0 90 Pitch angle 0 Skew angle 15 Tilt angle 45 Software Parameters Reading Mode Linear Reading Distance Horizontal Reading Width 8 12 16...

Страница 144: ...e reader Dust dirt etc on the window may alter the reading performance Repeat the operation frequently in particularly dirty environments Use soft material and alcohol to clean the window and avoid an...

Страница 145: ...you can refer to the Genius program help files Either connect the device and select the parameter you re interested in by pressing the F1 key or select Help Parameters Help 5K Software Configuration P...

Страница 146: ...ode branch and check if Serial On Line is selected in the On Line Options Are the Start Stop characters correctly assigned Is the serial trigger source correctly connected and configured On line Mode...

Страница 147: ...e is not transmitting anything to the host Is the serial cable connected Is the correct wiring respected Are serial host settings equivalent to the serial device setting If using CBX be sure the RS485...

Страница 148: ...25 1 CDRH READING FEATURES Note 1 Scan Rate software programmable 800 scans sec Aperture Angle 65 Oscillating Amplitude OM models 40 2 5 to 35 Oscillating Frequency OM models 0 2 to 20 Hz 5 Hz max 40...

Страница 149: ...39 Standard and Full ASCII EAN 128 Codabar ISBT 128 ABC Codabar Pharmacode GS1 DataBar Plessey GS1 DataBar Expanded GS1 DataBar Limited ACR4 Readable Code Selection up to ten different symbologies du...

Страница 150: ...y input voltage 1 CHASSIS Cable shield connected to chassis 18 I1A External Trigger A polarity insensitive 19 I1B External Trigger B polarity insensitive 6 I2A Input 2 A polarity insensitive 10 I2B In...

Страница 151: ...input The electrical features of both inputs are V AB Max I IN Max 30 V 12 mA The relative pins on the 25 pin D sub connector are Pin Name Function 9 Vdc Power Supply input voltage 18 I1A External Tr...

Страница 152: ...22 O1 Configurable digital output 1 11 O2 Configurable digital output 2 12 O2 Configurable digital output 2 The electrical features of the two outputs are the following VBCEB max 30 Vdc 40 mA continuo...

Страница 153: ...D 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable The following wiring diagram shows a simple test cable including power external push button trigger and PC RS232 COM port connectio...

Страница 154: ...nnector case provides electrical connection to the chassis 6 I1A External Trigger A polarity insensitive 5 I1B External Trigger B polarity insensitive 13 I2A Input 2 A polarity insensitive 3 I2B Input...

Страница 155: ...ET NETWORK TERMINATION The network must be properly terminated by a 120 Ohm resistor at the first and last reader of the network INPUTS There are two optocoupled polarity insensitive inputs available...

Страница 156: ...gital output 1 8 O2 Configurable digital output 2 2 GND Output reference signal The electrical features of the two outputs are the following Reverse Polarity and Short Circuit Protected VOUT ILOAD 0 m...

Страница 157: ...ner USER INTERFACE Vext 9 8 2 Vdc Figure 85 NPN Output Connection CAUTION For NPN output connections the external interface voltage Vext must not exceed the scanner power supply source voltage Vdc oth...

Страница 158: ...Pinout Pin Name Function 1 TX Transmitted data 2 RX Received data 3 TX Transmitted data 4 RX Received data POWER INPUT TRIGGER Figure 87 M12 A Coded 5 pin Male Power Connector Power Connector Pinout P...

Страница 159: ...governing acceptable limitations on electronic radiation from laser devices Datalogic devices are in compliance with the CDRH regulations Code Positioning Variation in code placement that affects the...

Страница 160: ...Orientation When the barcode s bars are positioned vertically on the product causing them to appear as a picket fence The first bar will enter the scan window first See par 6 2 2 Pitch Rotation of a c...

Страница 161: ...ends of all bars will enter the scan window first See par 6 2 1 Symbol A combination of characters including start stop and checksum characters as required that form a complete scannable barcode Tilt...

Страница 162: ...NET Interface 60 ID NET Multidata Networks 88 ID NET Network Termination 65 135 139 ID NET Response Time 61 ID NET Synchronized Networks 83 Inputs 66 135 139 IP Address Alignment Using Genius Discover...

Страница 163: ...147 X X PRESS Human Machine Interface 23...

Страница 164: ......

Отзывы: