DS5100 REFERENCE MANUAL
138
B
B ALTERNATIVE CONNECTIONS FOR ETHERNET MODELS
The connector pinouts and notes given in this appendix are for custom cabling applications.
POWER, COM AND I/O CONNECTOR
The scanner is equipped with an M12 17-pin male connector for connection to the power
supply, serial interfaces and input/output signals. The details of the connector pins are
indicated in the following table:
Figure 81
– M12 17-pin male COM, I/O and Power Connector
Power, COM and I/O Connector Pinout
Pin
Name
Function
1
Vdc
Power supply input v
2
GND
Power supply input voltage -
Connector
case
CHASSIS
Connector case provides electrical connection to the
chassis
6
I1A
External Trigger A (polarity insensitive)
5
I1B
External Trigger B (polarity insensitive)
13
I2A
Input 2 A (polarity insensitive)
3
I2B
Input 2 B (polarity insensitive)
9
O1
Output 1
(NPN or PNP short circuit protected
and software programmable)
8
O2
Output 2
16
NC
Not connected
14
RX
Auxiliary RS232 RX
4
TX
Auxiliary RS232 TX
7
ID+
ID-NET n
15
ID-
ID-NET network -
Pin
Name
RS232
RS485/422 Full-Duplex
17
MAIN INTERFACE
(SW SELECTABLE)
Reference to GND
TX
TX+
11
RX
*
RX+
12
RTS
TX-
10
CTS
*
RX-
* Do not leave floating, if not used connect to GND.
In order to meet EMC requirements:
connect the reader chassis to the plant earth ground by means of a flat copper braid
shorter than 100 mm;
connect your cable shield to the locking ring nut of the connector.
Содержание DS5100
Страница 1: ......
Страница 29: ...RAPID CONFIGURATION 13 1 b Operating mode selection and definition a Digital Inputs configuration...
Страница 30: ...DS5100 REFERENCE MANUAL 14 1 b Digital Outputs configuration c Hardware interface selection...
Страница 62: ...DS5100 REFERENCE MANUAL 46 3 Figure 18 DS5100 OM Serial Model Overall Dimensions...
Страница 78: ...DS5100 REFERENCE MANUAL 62 4 Figure 38 ID NET Network Connections with isolated power blocks...
Страница 79: ...ELECTRICAL INSTALLATION 63 4 Figure 39 ID NET Network Connections with Common Power Branch Network...
Страница 80: ...DS5100 REFERENCE MANUAL 64 4 Figure 40 ID NET Network Connections with Common Power Star Network...
Страница 97: ...TYPICAL LAYOUTS 81 5 7 Double click on the DS5100 scanner to configure it...
Страница 163: ...147 X X PRESS Human Machine Interface 23...
Страница 164: ......