![Datalogic DS5100 Скачать руководство пользователя страница 100](http://html1.mh-extra.com/html/datalogic/ds5100/ds5100_reference-manual_3666375100.webp)
DS5100 REFERENCE MANUAL
84
5
NOTE:
The auxiliary serial interface
of the slave scanners
can be used in
Local Echo communication mode to control any single scanner (visualize
collected data) or to configure it using the Genius utility or the Genius based
Host Mode programming procedure.
The ID-NET termination resistor switches must be set to ON only in the first and
last CBX connection box.
Figure 61
– ID-NET Synchronized Layout
DS5100 Master with DS5100 Slaves with QL100
Figure 62
– ID-NET Synchronized Layout
DS5100 Master with QL500 + DS5100 Slaves with QL100
Host
QL100
PS
Power
Ethernet Interface
CBL-1490
ID-NET
Terminator
The ID-NET network must be terminated inserting
an ID-NET terminator into the last QL in the
network.
ID-NET on the QL500 is internally terminated.
Slave Nodes
CBL-1480-xx
CAB-PW-EXT
CBL-1480-xx
QL500
Master
QL100
ID-NET
Host
QL100
3
1 4
PS
Power
CBX500 w BM200
CBL-1490
ID-NET
Terminator
The ID-NET network must be terminated through
the internal switch of the CBX500 and inserting
an ID-NET terminator into the last QL in the
network.
ID-NET Slave Nodes
5
CAB-PW-EXT
CAB-AUX03
CBL-1480-xx
BA600 ID-
NET™ Out
BA400 Ext. Power
BA500 Trigger
BA300 Service
Master
QL100
Ethernet
CBL-1480-xx
Содержание DS5100
Страница 1: ......
Страница 29: ...RAPID CONFIGURATION 13 1 b Operating mode selection and definition a Digital Inputs configuration...
Страница 30: ...DS5100 REFERENCE MANUAL 14 1 b Digital Outputs configuration c Hardware interface selection...
Страница 62: ...DS5100 REFERENCE MANUAL 46 3 Figure 18 DS5100 OM Serial Model Overall Dimensions...
Страница 78: ...DS5100 REFERENCE MANUAL 62 4 Figure 38 ID NET Network Connections with isolated power blocks...
Страница 79: ...ELECTRICAL INSTALLATION 63 4 Figure 39 ID NET Network Connections with Common Power Branch Network...
Страница 80: ...DS5100 REFERENCE MANUAL 64 4 Figure 40 ID NET Network Connections with Common Power Star Network...
Страница 97: ...TYPICAL LAYOUTS 81 5 7 Double click on the DS5100 scanner to configure it...
Страница 163: ...147 X X PRESS Human Machine Interface 23...
Страница 164: ......