DS5100 REFERENCE MANUAL
94
6
6.1.3 ACR Reading Conditions for Long Range Models
The following tables describe the minimum code height requirements (
in mm
) for standard
ACR4 applications depending on the code symbology and the given reading conditions.
ANSI Grade B minimum
2/5 Interleaved
Minimum Code Height for ACR4 Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
Code Resolution
(mm)
0.25
10 11 13 14 16 17
7
8
9
10 12 13
0.30
12 13 14 16 17 19
8
9
10 11 12 14
0.33
12 14 15 17 18 20
8
9
10 12 13 14
0.38
14 15 16 18 19 21
9
10 11 12 14 15
0.50
18 18 20 21 23 24 11 12 13 14 15 17
0.72
24 25 26 27 28 30 15 16 16 18 19 20
1.00
33 33 34 35 36 37 20 20 21 22 23 24
Ratio 3:1
Table 6
Code 39
Minimum Code Height for ACR4 Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
Code Resolution
(mm)
0.25
9
9
11 12 14 15
6
7
8
9
10 11
0.30
10 11 12 13 15 16
7
7
8
10 11 12
0.33
11 11 12 14 15 17
7
8
9
10 11 12
0.38
12 13 13 15 16 18
8
8
9
10 12 13
0.50
15 16 16 17 18 20
9
10 11 12 13 14
0.72
20 21 22 22 23 24 13 13 14 14 15 16
1.00
27 28 29 29 30 31 17 17 18 18 19 20
Ratio 3:1; Interdigit = Module Size
Table 7
Code 128
– GS1-128
Minimum Code Height for ACR4 Reading (mm)
45° max
30° max
Conveyor Speed (m/s)
0.5
1
1.5
2
2.5
3
0.5
1
1.5
2
2.5
3
Code Resolution
(mm)
0.25
7
9
10 12 13 15
6
6
8
9
10 11
0.30
8
9
11 12 14 15
6
7
8
9
10 12
0.33
9
10 11 13 14 16
6
7
8
9
11 12
0.38
10 11 12 14 15 17
6
8
9
10 11 12
0.50
12 13 14 16 17 19
8
9
10 11 12 13
0.72
16 17 18 19 21 22 10 11 12 13 14 15
1.00
21 22 23 24 25 26 13 14 15 16 17 18
Table 8
Содержание DS5100
Страница 1: ......
Страница 29: ...RAPID CONFIGURATION 13 1 b Operating mode selection and definition a Digital Inputs configuration...
Страница 30: ...DS5100 REFERENCE MANUAL 14 1 b Digital Outputs configuration c Hardware interface selection...
Страница 62: ...DS5100 REFERENCE MANUAL 46 3 Figure 18 DS5100 OM Serial Model Overall Dimensions...
Страница 78: ...DS5100 REFERENCE MANUAL 62 4 Figure 38 ID NET Network Connections with isolated power blocks...
Страница 79: ...ELECTRICAL INSTALLATION 63 4 Figure 39 ID NET Network Connections with Common Power Branch Network...
Страница 80: ...DS5100 REFERENCE MANUAL 64 4 Figure 40 ID NET Network Connections with Common Power Star Network...
Страница 97: ...TYPICAL LAYOUTS 81 5 7 Double click on the DS5100 scanner to configure it...
Страница 163: ...147 X X PRESS Human Machine Interface 23...
Страница 164: ......