![Datalogic DS5100 Скачать руководство пользователя страница 150](http://html1.mh-extra.com/html/datalogic/ds5100/ds5100_reference-manual_3666375150.webp)
DS5100 REFERENCE MANUAL
134
A
A ALTERNATIVE CONNECTIONS FOR SERIAL MODELS
The connector pinouts and notes given in this appendix are for custom cabling applications.
POWER, COM AND I/O CONNECTOR
The scanner is equipped with a cable ending in a 25-pin male D-sub connector for
connection to the power supply, serial interfaces and input/output signals. The details of the
connector pins are indicated in the following table:
13
25
14
1
Figure 76 - 25-pin Male D-sub Connector
25-pin D-sub male connector pinout
Pin
Name
Function
13, 9
Vdc
Power supply input v
25, 7
GND
Power supply input voltage -
1
CHASSIS
Cable shield connected to chassis
18
I1A
External Trigger A (polarity insensitive)
19
I1B
External Trigger B (polarity insensitive)
6
I2A
Input 2 A (polarity insensitive)
10
I2B
Input 2 B (polarity insensitive)
8
O1+
Output 1 +
22
O1-
Output 1 -
11
O2+
Output 2 +
12
O2-
Output 2 -
20
RX
Auxiliary RS232 RX
21
TX
Auxiliary RS232 TX
23
ID+
ID-NET n
24
ID-
ID-NET network -
14, 15, 16, 17 NC
Not Connected
Pin
Name
RS232
RS485
Full-Duplex
2
MAIN INTERFACE
(SW SELECTABLE)
Reference to GND
TX
TX+
3
RX
*
RX+
4
RTS
TX-
5
CTS
*
RX-
* Do not leave floating, if not used connect to GND.
In order to meet EMC requirements:
connect the reader chassis to the plant earth ground by means of a flat copper braid
shorter than 100 mm;
connect your cable shield to the locking ring nut of the connector.
Содержание DS5100
Страница 1: ......
Страница 29: ...RAPID CONFIGURATION 13 1 b Operating mode selection and definition a Digital Inputs configuration...
Страница 30: ...DS5100 REFERENCE MANUAL 14 1 b Digital Outputs configuration c Hardware interface selection...
Страница 62: ...DS5100 REFERENCE MANUAL 46 3 Figure 18 DS5100 OM Serial Model Overall Dimensions...
Страница 78: ...DS5100 REFERENCE MANUAL 62 4 Figure 38 ID NET Network Connections with isolated power blocks...
Страница 79: ...ELECTRICAL INSTALLATION 63 4 Figure 39 ID NET Network Connections with Common Power Branch Network...
Страница 80: ...DS5100 REFERENCE MANUAL 64 4 Figure 40 ID NET Network Connections with Common Power Star Network...
Страница 97: ...TYPICAL LAYOUTS 81 5 7 Double click on the DS5100 scanner to configure it...
Страница 163: ...147 X X PRESS Human Machine Interface 23...
Страница 164: ......