iv
COMPLIANCE
For installation, use, and maintenance, it is not necessary to open the camera. Opening
the camera will void the warranty.
Connect Ethernet and dataport connections to a network which has routing only within
the plant or building and no routing outside the plant or building.
EMC COMPLIANCE
In order to meet the EMC requirements:
•
connect the camera chassis to the plant earth ground by means of a flat copper braid shorter
than 100 mm;
•
for CBX connections, connect the pin "Earth" to a good Earth Ground;
•
for direct connections, connect the main interface cable shield to pin K of the 19-pin
connector.
POWER SUPPLY
ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT
This product is intended to be installed by Qualified Personnel only.
This product is intended to be connected to a UL Listed Direct Plug-in Power Unit
marked LPS or “Class 2”, rated 10-30Vdc 1-0.33A.
CE COMPLIANCE
Warning:
This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate measures.
FCC COMPLIANCE
Modifications or changes to this equipment without the expressed written approval of DLA could
void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at the user’s own
expense.
Содержание A30
Страница 1: ...A30 Hardware Guide Publication 843 0153 Rev B...
Страница 10: ......
Страница 20: ...A30 HARDWARE GUIDE 10 3 Figure 5 Mounting Bracket Overall Dimensions mm in...
Страница 28: ...A30 HARDWARE GUIDE 18 4 Figure 17 NPN External Trigger Using External Power...
Страница 30: ...A30 HARDWARE GUIDE 20 4 Figure 21 NPN Input 2 Using External Power...
Страница 45: ...CAMERA ELECTRICAL CONNECTIONS 35 5 Figure 42 Open Collector Output Connection...
Страница 55: ...SOFTWARE CONFIGURATION 45 8...
Страница 64: ...www datalogic com...