A30™ HARDWARE GUIDE
30
5
5.6 INPUTS
There are two optocoupled polarity insensitive inputs available on the M16 19-pin connector of
the camera: Input 1 (External Trigger) and Input 2, a generic input.
The External Trigger is the image acquisition trigger.
The main function of the general purpose Input 2 is to detect an input signal.
The electrical features of both inputs are:
INPUT
| V
AB
| Min. | V
AB
| Max.
I
IN
Max
.
Open
0 V
2 V
0 mA
Closed
4.5 V
30 V
10 mA
The active states of these inputs are selected in software.
An anti-disturbance filter is implemented in software on both inputs so that the minimum pulse
duration is
≅
0.5 milliseconds. This value can be increased through the software parameter
Debounce Filter. Refer to the Camera Setup tab section in the Impact Reference Guide for
further details.
These inputs are optocoupled and can be driven by both NPN and PNP type commands.
NOTE
Polarity insensitive inputs assure full functionality even if pins A and B are
exchanged.
The connections are indicated in the following diagrams:
Pin Name
Function
A
Vdc
Power Supply input v
B
I1A
External Trigger A (polarity insensitive)
C
I1B
External Trigger B (polarity insensitive)
L
GND
Power Supply input voltage -
The Busy LED is on when the active state of the External Trigger corresponds to ON.
Содержание A30
Страница 1: ...A30 Hardware Guide Publication 843 0153 Rev B...
Страница 10: ......
Страница 20: ...A30 HARDWARE GUIDE 10 3 Figure 5 Mounting Bracket Overall Dimensions mm in...
Страница 28: ...A30 HARDWARE GUIDE 18 4 Figure 17 NPN External Trigger Using External Power...
Страница 30: ...A30 HARDWARE GUIDE 20 4 Figure 21 NPN Input 2 Using External Power...
Страница 45: ...CAMERA ELECTRICAL CONNECTIONS 35 5 Figure 42 Open Collector Output Connection...
Страница 55: ...SOFTWARE CONFIGURATION 45 8...
Страница 64: ...www datalogic com...