CBX ELECTRICAL CONNECTIONS
23
4
4.6 EXTERNAL ILLUMINATORS
If an External Illuminator (strobe light) is used, it can be powered from the CBX connection box.
It must be connected to the
Vdc
and
GND
terminal clamps. The strobe signal connection is
shared with Output 3. If a non-zero value is defined for the Strobe Pulse Length value (in VPM –
Impact – General), the strobe is active. If the value is zero, Output 3 is active.
CAUTION
Power is available directly to the strobe, independently from the Power
Supply Switch inside the CBX.
Configure the Strobe Signal in the VPM software. Refer to the Camera Setup tab section of the
Impact Reference Guide.
Figure 26 – External Illuminator Connections
Below is a table summarizing the External Illuminator wiring and power requirements.
CBX/Camera Signal
Meaning
Vdc
10 to 30 Vdc
GND
Ground
Earth
Shield/Earth Ground
O3B
Control Signal – (See Note)
O3A
Control
Note: The strobe signal connection is shared with Output 3. If a non-zero value is
defined for the Strobe Pulse Length value (in VPM – Impact – General), the strobe is
active. If the value is zero, Output 3 is active.
Содержание A30
Страница 1: ...A30 Hardware Guide Publication 843 0153 Rev B...
Страница 10: ......
Страница 20: ...A30 HARDWARE GUIDE 10 3 Figure 5 Mounting Bracket Overall Dimensions mm in...
Страница 28: ...A30 HARDWARE GUIDE 18 4 Figure 17 NPN External Trigger Using External Power...
Страница 30: ...A30 HARDWARE GUIDE 20 4 Figure 21 NPN Input 2 Using External Power...
Страница 45: ...CAMERA ELECTRICAL CONNECTIONS 35 5 Figure 42 Open Collector Output Connection...
Страница 55: ...SOFTWARE CONFIGURATION 45 8...
Страница 64: ...www datalogic com...