- 43 -
STATUS LEDS:
LINE (MAIN RELAY)
: If RUN mode is selected and there are no conditions to prevent the
compressor from starting, the main relay engages and this LED turns on.
LOAD (LOAD RELAY)
: If the load relay is engaged (the compressor is running under load and
generating compressed air) this LED turns on.
ALARM:
If an alarm condition occurs, this LED turns on.
SERVICE REQUEST:
If one of the service counters expires, this LED turns on.
PROGRAMMABLE LEDS:
The controller offers 2 LEDs which can be user defined. Any alarm, input or
relay function can be assigned to these LEDs.
MODE LEDS:
The relevant LED turns on when a mode is selected either from the physical device or
remotely.
7.5. LED LAMPS
Alarm indicator
STOP mode
indicator
Service
request
indicator
RUN mode
indicator
LINE
(MAIN relay)
status indicator
LOAD
(Load relay)
status
indicator
Programmable
LED indicators
Содержание DK-70
Страница 10: ...10 Dimensions 211x162x42mm Panel cutout 176x121mm minimum Weight 500g approx 2 1 DIMENSIONS 2 MOUNTING...
Страница 31: ...31 4 4 3 PHASE 3 WIRE DELTA 2 CT L1 L3 4 3 3 PHASE 3 WIRE DELTA 2 CT L1 L2...
Страница 32: ...32 4 6 1 PHASE 2 WIRE 4 5 2 PHASE 3 WIRE DELTA 2 CTs L1 L2...