70
Troubleshooting
The magnetic stripe data
was sent in an encoding
format not supported by
the track.
Review the encoding format setting for the tracks in Printer
Manager. Refer to “MagStripeGeneral” in the printer’s
Installation and Administrator’s Guide for more information.
Make sure that the application is using the selected encoding
format for the track.
If the application and track are set to the same format, and
the error message displays repeatedly, contact the application
provider for assistance.
The application sent track
data for a track not
supported by the
magnetic stripe module.
Verify the type of magnetic stripe option in the printer.
If the printer label indicates a 3-track ISO module, you can
send data for tracks 1, 2, and 3.
If the printer label indicates a single-track JIS module, you can
send data for track 1.
The magnetic stripe option and cards must be capable of
accepting and encoding each track of data sent by the card
production software.
Problem
Solution
Содержание CR805
Страница 1: ...Entrust Datacard CR805 Retransfer Card Printer User s Guide September 2017 Part No 527691 001 Rev C...
Страница 8: ...viii...
Страница 10: ...x...
Страница 16: ...xvi...
Страница 18: ...2 Introduction...
Страница 32: ...16 About the Printer...
Страница 58: ...42 Using the Printer...