Pa
r.
No
.
#
Pa
rame
ter de
scri
pt
io
n
De
fa
ult va
lue
(SR = S
ize
rel
ate
d)
4 set-up
Change during
op
er-
ati
on
Conve
r-
sion
inde
x
Type
20
-0* Feed
bac
k
20-
00
Feed
ba
ck 1 S
ource
[2
] A
nal
og in
pu
t
54
Al
l s
et
-up
s
TR
U
E
-
Ui
nt
8
20-
01
Feed
ba
ck 1
Conversi
on
[0
] L
in
ear
Al
l s
et
-u
ps
FALSE
-
Ui
nt8
20-
02
Fee
db
ack 1 S
ource
U
ni
t
null
All
set-
up
s
TR
U
E
-
Ui
nt
8
20-
03
Feed
ba
ck 2 S
ource
[0] No
fu
ncti
on
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
20-
04
Fee
db
ack 2
Co
nversi
on
[0
] Li
ne
ar
Al
l set-
up
s
FALSE
-
U
in
t8
20-
05
Feed
ba
ck 2 S
ource
U
ni
t
null
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
20-
06
Fee
db
ack 3 S
ource
[0] No
fu
ncti
on
Al
l set-
up
s
TR
U
E
-
Ui
nt
8
20-
07
Feed
ba
ck 3
Conversi
on
[0
] L
in
ear
Al
l s
et
-u
ps
FALSE
-
Ui
nt8
20-
08
Fee
db
ack 3 S
ource
U
ni
t
null
All
set-
up
s
TR
U
E
-
Ui
nt
8
20-
12
Reference/
Feed
ba
ck Uni
t
null
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
20-13
Mi
ni
mum Reference/
Feed
b.
0.000
Pr
ocessCtrlU
nit
Al
l set-u
ps
TRUE
-3
Int32
20-
14
Max
imum Ref
eren
ce/Fe
edb
.
100.000 ProcessCtrlU
ni
t
Al
l s
et
-u
ps
TRU
E
-3
Int3
2
20
-2* Fee
d
bac
k
& Se
tpoi
nt
20-
20
Feed
ba
ck Function
[3]
Mini
mum
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
20-
21
Setp
oi
nt 1
0.000 Pr
ocessCtrlU
nit
Al
l set-u
ps
TRUE
-3
Int32
20-
22
Se
tpo
int 2
0.000 Pr
ocessCtrlU
nit
Al
l s
et
-u
ps
TRU
E
-3
Int3
2
20-
23
Se
tpo
int 3
0.000 Pr
ocessCtrlU
nit
Al
l s
et
-u
ps
TRU
E
-3
Int3
2
20
-3* Fe
edback
Adv
. Co
n
v.
20-
30
Re
fri
gera
nt
[0
] R2
2
Al
l s
et
-up
s
TR
U
E
-
Ui
nt
8
20-
31
U
ser-
def
ine
d R
efri
ge
rant
A1
10
.0
000 N/
A
Al
l s
et
-u
ps
TRU
E
-4
Ui
nt3
2
20-
32
Use
r-d
ef
in
ed
Re
frig
erant
A2
-22
50.
00 N/
A
All
set-
up
s
TR
U
E
-2
Int32
20-
33
U
ser-
def
ine
d R
efri
ge
rant
A3
250.
000 N/
A
Al
l s
et
-u
ps
TRU
E
-3
Ui
nt3
2
20
-6* Sen
sorl
ess
20-
60
Senso
rle
ss Unit
null
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
20-
69
Senso
rle
ss Informa
tio
n
0 N/A
Al
l s
et
-u
ps
TRU
E
0
Vi
sS
tr[2
5]
20
-7* PID
Au
to Tu
n
in
g
20-
70
Closed-
lo
op Type
[0] Auto
2 set-up
s
TR
U
E
-
Ui
nt
8
20-
71
Tun
ing Mod
e
[0] No
rmal
2 set-up
s
TRU
E
-
Ui
nt8
20-
72
PI
D Outp
ut
Chang
e
0.
10 N/
A
2 set-up
s
TR
U
E
-2
U
int16
20-
73
Mi
ni
mum Feedback Level
-9999
99.000 ProcessCtrlU
nit
2 set-up
s
TRU
E
-3
Int3
2
20-74
Maxi
mum Feed
ba
ck Le
vel
999
999.000
ProcessCtrlU
ni
t
2 set-up
s
TRUE
-3
Int32
20-
79
PID Auto
Tuning
[0
] Di
sabl
ed
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
20
-8*
PID
Basic
Set
ti
n
g
s
20-
81
PID Norma
l/ Inve
rse
Cont
rol
[0] No
rmal
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
20-82
PID
St
art Spee
d [
R
PM]
Expressio
nLi
mit
All
se
t-u
ps
TRUE
67
U
int16
20-
83
PID St
art
Spee
d [Hz]
Ex
pressio
nLimit
Al
l s
et
-u
ps
TRU
E
-1
Ui
nt1
6
20-
84
On
Re
fe
re
nc
e Ba
nd
w
idt
h
5 %
Al
l s
et
-u
ps
TRU
E
0
Ui
nt8
20
-9* PID
Con
tr
o
lle
r
20-
91
PID Anti
Windup
[1] On
Al
l s
et
-up
s
TR
U
E
-
Ui
nt
8
20-
93
PI
D Pro
port
ion
al
Ga
in
0.
50 N/
A
Al
l s
et
-u
ps
TRU
E
-2
Ui
nt1
6
20-
94
PI
D I
nteg
ral
Ti
me
20.
00 s
All
set-
up
s
TR
U
E
-2
U
int32
20-
95
PI
D Diffe
rentiat
ion
Time
0.0
0 s
Al
l s
et
-u
ps
TRU
E
-2
Ui
nt1
6
20-
96
PI
D Diff. Gain
Li
mit
5.
0 N/
A
All
set-
up
s
TR
U
E
-1
U
int16
6.2.1
8
20-*
*
FC
Closed-loop
VLT
®
HVAC Drive Instruction Manual
6 How to program the adjustable frequency
drive
MG.11.A9.22 - VLT
®
is a registered Danfoss trademark
6-77
6