Pa
r.
No
.
#
Pa
rame
ter de
scri
pt
io
n
De
fa
ult va
lue
(SR = S
ize
rel
ate
d)
4 set-up
Change during
op
er-
ati
on
Conve
r-
sion
inde
x
Type
23
-0* Time
d Ac
ti
ons
23-
00
ON Ti
me
Ex
pressio
nLimit
2 set-up
s
TR
U
E
0
Ti
m
eOf
D
ay-
Wo
D
ate
23-
01
ON Actio
n
[0
] DI
SA
BL
ED
2 set-up
s
TRU
E
-
Ui
nt8
23-
02
OFF Tim
e
Ex
pressio
nLimit
2 se
t-
ups
TRUE
0
Ti
m
eOf
D
ay-
Wo
D
ate
23-
03
OFF Ac
tion
[0
] DI
SA
BL
ED
2 set-up
s
TRU
E
-
Ui
nt8
23-
04
Occurrence
[0
] Al
l days
2 set-up
s
TRU
E
-
Ui
nt8
23
-1* Mai
n
te
nan
ce
23-
10
Mainte
nance
Ite
m
[1
] M
oto
r b
earing
s
1 se
t-
up
TRUE
-
U
in
t8
23-
11
Mainte
nance
Ac
tion
[1] L
ub
ric
ate
1 set-up
TRU
E
-
Ui
nt8
23-
12
Maintenance Tim
e Base
[0
]
Disab
le
d
1 set-up
TR
UE
-
U
in
t8
23-
13
Mainte
nance
Tim
e Int
erva
l
1 h
1 set-up
TRU
E
74
Ui
nt3
2
23-
14
Mainte
nance
Dat
e a
nd
Ti
me
Ex
pressio
nLimit
1 set-up
TRU
E
0
Ti
meOfDa
y
23
-1* Mai
n
te
nan
ce
Rese
t
23-
15
Re
set Mai
ntena
nce
W
ord
[0] Do
no
t re
set
Al
l s
et
-up
s
TR
U
E
-
Ui
nt
8
23-
16
Mainte
nance
Text
0 N/A
1 set-up
TRU
E
0
Vi
sS
tr[2
0]
23
-5* Ene
rg
y Log
23-
50
En
erg
y Lo
g
Reso
lut
ion
[5
] Last 24
Hours
2 set-up
s
TRU
E
-
Ui
nt8
23-
51
Pe
riod
St
art
Ex
pressio
nLimit
2 se
t-
ups
TRUE
0
TimeOfDa
y
23-
53
En
er
gy
L
og
0 N/A
Al
l s
et
-u
ps
TRU
E
0
Ui
nt3
2
23-
54
Re
set E
nergy
Lo
g
[0] Do
no
t re
set
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
23
-6* Tr
en
di
ng
23-
60
Tre
nd Va
ria
ble
[0] Po
w
er [kW]
2 set-up
s
TR
U
E
-
Ui
nt
8
23-
61
Co
nt
in
uo
us
B
in
D
ata
0 N/A
Al
l s
et
-u
ps
TRU
E
0
Ui
nt3
2
23-
62
Tim
ed
Bin
Data
0 N/A
All
set-
up
s
TR
U
E
0
U
int32
23-
63
Tim
ed P
eriod
Sta
rt
Ex
pressio
nLimit
2 set-up
s
TRU
E
0
Ti
meOfDa
y
23-
64
Tim
ed
P
eri
od
Stop
Exp
re
ssionLi
mit
2
set-up
s
TR
U
E
0
Ti
me
OfDay
23-
65
Mi
ni
mum Bin
Va
lu
e
Ex
pressio
nLimit
2 set-up
s
TRU
E
0
Ui
nt8
23-66
Re
set
Continuo
us Bin Data
[0] Do
not
rese
t
All se
t-u
ps
TRUE
-
Uin
t8
23-
67
Re
set Time
d
Bin Data
[0] Do
no
t re
set
Al
l s
et
-u
ps
TRU
E
-
Ui
nt8
23
-8* Payback
Coun
te
r
23-
80
Po
we
r Re
fer
ence Fa
ctor
100
%
2 set-up
s
TRU
E
0
Ui
nt8
23-
81
Ene
rgy Co
st
1.
00 N/
A
2 set-up
s
TR
U
E
-2
U
int32
23-
82
Inve
stm
ent
0 N/A
2 set-up
s
TRU
E
0
Ui
nt3
2
23-
83
Ene
rgy Savi
ng
s
0 kWh
All
set-
up
s
TR
U
E
75
Int32
23-
84
Cost
Sa
vings
0 N/A
Al
l s
et
-u
ps
TRU
E
0
Int3
2
6.2.2
1
23-*
*
Tim
e-based
Funtions
6 How to program the adjustable frequency
drive
VLT
®
HVAC Drive Instruction Manual
6-82
MG.11.A9.22 - VLT
®
is a registered Danfoss trademark
6
Содержание VLT
Страница 8: ...1 Safety VLT HVAC Drive Instruction Manual 1 6 MG 11 A9 22 VLT is a registered Danfoss trademark 1...
Страница 152: ...7 Troubleshooting VLT HVAC Drive Instruction Manual 7 8 MG 11 A9 22 VLT is a registered Danfoss trademark 7...
Страница 174: ...8 Specifications VLT HVAC Drive Instruction Manual 8 22 MG 11 A9 22 VLT is a registered Danfoss trademark 8...