16-80 Fieldbus CTW 1
0 N/A
1 set-up
TRUE
0
Uint16
16-82 Fieldbus REF 1
0 N/A
1 set-up
TRUE
0
Int16
16-84 Comm. Option STW
0 N/A
1 set-up
TRUE
0
Uint16
16-85 FC Port CTW 1
1084 N/A
1 set-up
FALSE
0
uint16
16-86 FC Port REF 1
0 N/A
1 set-up
TRUE
0
Int16
16-9* Diagnosis Readouts
16-90 Alarm Word
0 N/A
1 set-up
TRUE
0
Uint32
16-91 Alarm Word 2
0 N/A
1 set-up
TRUE
0
Uint32
16-92 Warning Word
0 N/A
1 set-up
TRUE
0
Uint32
16-93 Warning Word 2
0 N/A
1 set-up
TRUE
0
Uint32
16-94 Ext. Status Word
0 N/A
1 set-up
TRUE
0
Uint32
16-95 Ext. Status Word 2
0 N/A
1 set-up
TRUE
0
Uint32
16-97 Alarm Word 3
0 N/A
1 set-up
TRUE
0
Uint32
5.2.17 18-** Data Readouts 2
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
18-9* PID Readouts
18-90 Process PID Error
0 %
All set-ups
FALSE
-1
Int16
18-91 Process PID Output
0 %
All set-ups
FALSE
-1
Int16
18-92 Process PID Clamped Output
0 %
All set-ups
FALSE
-1
Int16
18-93 Process PID Gain Scaled Output
0 %
All set-ups
FALSE
-1
Int16
5.2.18 21-** Ext. Closed Loop
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
21-0* Ext. CL Autotuning
21-09 Extended PID Enable
[0] Disabled
All set-ups
TRUE
-
Uint8
21-1* Ext. CL 1 Ref./Fb.
21-11 Ext. 1 Minimum Reference
0 ExtPID1Unit
All set-ups
TRUE
-3
Int32
21-12 Ext. 1 Maximum Reference
100 ExtPID1Unit
All set-ups
TRUE
-3
Int32
21-13 Ext. 1 Reference Source
[0] No function
All set-ups
TRUE
-
Uint8
21-14 Ext. 1 Feedback Source
[0] No function
All set-ups
TRUE
-
Uint8
21-15 Ext. 1 Setpoint
0 ExtPID1Unit
All set-ups
TRUE
-3
Int32
21-17 Ext. 1 Reference [Unit]
0 ExtPID1Unit
All set-ups
TRUE
-3
Int32
21-18 Ext. 1 Feedback [Unit]
0 ExtPID1Unit
All set-ups
TRUE
-3
Int32
21-19 Ext. 1 Output [%]
0 %
All set-ups
TRUE
0
Int32
Ext. CL 1 PID
21-20 Ext. 1 Normal/Inverse Control
[0] Normal
All set-ups
TRUE
-
Uint8
21-21 Ext. 1 Proportional Gain
0.01 N/A
All set-ups
TRUE
-2
Uint16
21-22 Ext. 1 Integral Time
10000 s
All set-ups
TRUE
-2
Uint32
21-23 Ext. 1 Differentation Time
0 s
All set-ups
TRUE
-2
Uint16
21-24 Ext. 1 Dif. Gain Limit
5 N/A
All set-ups
TRUE
-1
Uint16
Parameter Lists
Programming Guide
MG07C102
Danfoss A/S © 12/2015 All rights reserved.
129
5
5
Содержание VLT Midi Drive FC 280
Страница 1: ...Programming Guide VLT Midi Drive FC 280 vlt drives danfoss com ...
Страница 2: ......
Страница 143: ...Index Programming Guide MG07C102 Danfoss A S 12 2015 All rights reserved 141 ...