4.20 Parameters: 30-** Special Features
30-20 High Starting Torque Time [s]
Range:
Function:
Size related
*
[0 - 60 s] High starting torque time for PM
motors in VVC
+
mode without
feedback.
30-21 High Starting Torque Current [%]
Range:
Function:
Size related
*
[ 0 - 200.0 %] High starting torque time for PM
motors in VVC
+
mode without
feedback.
30-22 Locked Rotor Protection
Option:
Function:
[0]
*
Off
[1]
On
The locked rotor protection for PM motors.
30-23 Locked Rotor Detection Time [s]
Range:
Function:
0.10 s
*
[0.05 - 1 s] The locked rotor detection time for PM
motors.
30-83 Speed PID Proportional Gain
Range:
Function:
Size related
*
[0 - 1 ]