![Danfoss VLT Midi Drive FC 280 Скачать руководство пользователя страница 127](http://html.mh-extra.com/html/danfoss/vlt-midi-drive-fc-280/vlt-midi-drive-fc-280_programming-manual_506511127.webp)
10-33 Store Always
[0] Off
1 set-up
TRUE
-
Uint8
5.2.12 12-** Ethernet
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
12-0* IP Settings
12-00 IP Address Assignment
[10] DCP
1 set-up
TRUE
-
Uint8
12-01 IP Address
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-02 Subnet Mask
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-03 Default Gateway
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-04 DHCP Server
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-05 Lease Expires
0 N/A
All set-ups
TRUE
0
TimD
12-06 Name Servers
0 N/A
1 set-up
TRUE
0
OctStr[4]
12-07 Domain Name
0 N/A
1 set-up
TRUE
0
VisStr[48]
12-08 Host Name
0 N/A
1 set-up
TRUE
0
VisStr[48]
12-09 Physical Address
0 N/A
1 set-up
TRUE
0
VisStr[17]
12-1* Ethernet Link Parameters
12-10 Link Status
[0] No Link
All set-ups
TRUE
-
Uint8
12-11 Link Duration
ExpressionLimit
All set-ups
TRUE
0
TimD
12-12 Auto Negotiation
[1] On
1 set-up
TRUE
-
Uint8
12-13 Link Speed
[0] None
1 set-up
TRUE
-
Uint8
12-14 Link Duplex
[1] Full Duplex
1 set-up
TRUE
-
Uint8
12-8* Other Ethernet Services
12-80 FTP Server
[0] Disabled
1 set-up
TRUE
-
Uint8
12-81 HTTP Server
[0] Disabled
1 set-up
TRUE
-
Uint8
12-82 SMTP Service
[0] Disabled
1 set-up
TRUE
-
Uint8
12-89 Transparent Socket Channel Port
4000 N/A
1 set-up
TRUE
0
Uint16
12-9* Advanced Ethernet Services
12-90 Cable Diagnostic
[0] Disabled
1 set-up
TRUE
-
Uint8
12-91 Auto Cross Over
[1] Enabled
1 set-up
TRUE
-
Uint8
12-92 IGMP Snooping
[1] Enabled
1 set-up
TRUE
-
Uint8
12-93 Cable Error Length
0 N/A
1 set-up
TRUE
0
Uint16
12-94 Broadcast Storm Protection
-1 %
1 set-up
TRUE
0
Int8
12-95 Broadcast Storm Filter
[0] Broadcast only
1 set-up
TRUE
-
Uint8
12-96 Port Config
ExpressionLimit
1 set-up
TRUE
-
Uint8
12-98 Interface Counters
4000 N/A
All set-ups
TRUE
0
Uint32
12-99 Media Counters
0 N/A
All set-ups
TRUE
0
Uint32
5.2.13 13-** Smart Logic Control
Param
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
13-0* SLC Settings
13-00 SL Controller Mode
[0] Off
1 set-up
TRUE
-
Uint8
13-01 Start Event
[39] Start command
1 set-up
TRUE
-
Uint8
13-02 Stop Event
[40] Drive stopped
1 set-up
TRUE
-
Uint8
13-03 Reset SLC
[0] Do not reset SLC
1 set-up
TRUE
-
Uint8
13-1* Comparators
13-10 Comparator Operand
[0] Disabled
1 set-up
TRUE
-
Uint8
13-11 Comparator Operator
[1] Approx.Equal (~)
1 set-up
TRUE
-
Uint8
13-12 Comparator Value
0 N/A
1 set-up
TRUE
-3
Int32
13-2* Timers
Parameter Lists
Programming Guide
MG07C102
Danfoss A/S © 12/2015 All rights reserved.
125
5
5
Содержание VLT Midi Drive FC 280
Страница 1: ...Programming Guide VLT Midi Drive FC 280 vlt drives danfoss com ...
Страница 2: ......
Страница 143: ...Index Programming Guide MG07C102 Danfoss A S 12 2015 All rights reserved 141 ...