9.3.33 Device under temperature (0x4220 / 0x138)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 73: Device under temperature (0x4220 / 0x138)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x4220 0x138
Device under tem-
perature
Error
The device is too cold to
operate.
undertemp de-
vice
9.3.34 Overtemperature: Control card (0x4291 / 0x106)
This error is valid for PSM 510, DAM 510, ACM 510, and ISD 510/DSD 510.
Table 74: Overtemperature: Control card (0x4291 / 0x106)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x4291 0x106
Overtemperature:
Control card
Error
Maximum temperature of con-
trol card exceeded.
overtemp CC
9.3.35 Overtemperature: Power card (0x4292 / 0x107)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 75: Overtemperature: Power card (0x4292 / 0x107)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x4292 0x107
Overtemperature:
Power card
Warning, error
Maximum temperature of pow-
er card exceeded.
overtemp PC
9.3.36 Inrush overtemperature DC link (0x4293 / 013C)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 76: Inrush overtemperature DC link (0x4293 / 0x13C)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x4293 0x13C
Inrush overtem-
perature: DC link
Error
Inrush fault.
Too many transitions into state
Operation
enabled
in a short time period.
UDC inrush
9.3.37 Inrush overtemperature AUX line (0x4294 / 0x13D)
This error is valid for DAM 510.
Table 77: Inrush overtemperature AUX line (0x4294 / 0x13D)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x4294 0x13D
Inrush overtem-
perature AUX line
Error
Inrush fault.
Too many power-ups of the AUX voltage
have occurred within a short time period.
UAUX in-
rush
9.3.38 Overtemperature: Motor (0x4310 / 0x108)
This error is valid for ISD 510/DSD 510.
AQ262449648484en-000101 / 175R1135 | 167
Danfoss A/S © 2020.08
Diagnostics
VLT® Servo Drive System ISD 510/DSD 510
Operating Guide