10.3 Inspection during Operation
10.3.1 ISD 510/DSD 510 Servo Drives
Carry out regular inspections during operation. Check the ISD 510/DSD 510 servo drives at regular intervals for anything unusual.
Pay particular attention to:
Unusual noises (ISD 510/DSD 510only).
Overheated surfaces (temperatures up to 100 °C can occur in normal operation).
Uneven running (ISD 510/DSD 510 only).
Strong vibrations.
Loose fastenings.
Condition of electrical wiring and cables.
Poor heat dispersion.
10.3.2 System Modules
Carry out regular inspections during operation.
Check:
The cooling vents are not blocked.
The fan is not making any unusual noises.
The condition of electrical wiring and cables.
10.4 Repair
Always contact the local Danfoss sales company for information about the repair policy.
10.5 ISD 510/DSD 510 Servo Drive Replacement
10.5.1 Dismounting the ISD 510/DSD 510 Servo Drive
Procedure
Disconnect the supply and wait for the discharge time to elapse.
Disconnect the electrical cables.
Dismount the servo drive.
Replace the servo drive with a servo drive of the same type. See the
VLT® Servo Drive System ISD 510, DSD 510, MSD 510
(VLT® Flexmotion
™
) Design Guide
for part numbers.
10.5.2 Fitting and Commissioning the ISD 510/DSD 510 Servo Drive
Procedure
Check if preparation is required (see
4.6.1 ISD 510/DSD 510 Servo Drive
Fit the servo drive (see
4.7.5.2 Clamping the ISD 510 Servo Drive
Connect the hybrid cables (see
5.9.3 Connecting Hybrid Cables
Connect the I/O and/or encoder cables (see
5.9.5.2 Connecting I/O and/or Encoder Cables to Port X3
Configure the servo drive parameters according to the fieldbus used (see
and
).
Conduct a test run.
10.6 System Module Replacement
10.6.1 Dismounting the System Modules
Disconnect the mains and all auxiliary supplies from the PSM 510 and wait for the discharge time to elapse.
Disconnect the EMC plate on the bottom of the system modules. Do not dismount the connectors from the EMC plate.
AQ262449648484en-000101 / 175R1135 | 177
Danfoss A/S © 2020.08
Maintenance, Decomissioning, and
Disposal
VLT® Servo Drive System ISD 510/DSD 510