Mechanical dimensions, 12-Pulse units, frame sizes F8-F13
Frame size
F8
F9
F10
F11
F12
F13
High overload rated
power - 160% overload
torque
250 - 400kW
(380 - 500V)
355 - 560kW
(525-690V)
250 - 400kW
(380 - 500V)
355 - 56kW
(525-690V)
450 - 630kW
(380 - 500V)
630 - 800kW
(525-690V)
450 - 630kW
(380 - 500V)
630 - 800kW
(525-690V)
710 - 800kW
(380 - 500V)
900 - 1200kW
(525-690V)
710 - 800kW
(380 - 500V)
900 - 1200kW
(525-690V)
IP
NEMA
21, 54
Type 1/Type 12
21, 54
Type 1/Type 12
21, 54
Type 1/Type 12
21, 54
Type 1/Type 12
21, 54
Type 1/Type 12
21, 54
Type 1/Type 12
Shipping
dimensions
[mm]
Height
2324
2324
2324
2324
2324
2324
Width
970
1568
1760
2559
2160
2960
Depth
1130
1130
1130
1130
1130
1130
Drive
dimensions
[mm]
Height
2204
2204
2204
2204
2204
2204
Width
800
1400
1600
2200
2000
2600
Depth
606
606
606
606
606
606
Max weight [kg]
440
656
880
1096
1022
1238
7.2 Mechanical Installation
Preparation of the mechanical installation of the frequency
converter must be done carefully to ensure a proper result
and to avoid additional work during installation. Start
taking a close look at the mechanical drawings at the end
of this instruction to become familiar with the space
demands.
7.2.1 Tools Needed
To perform the mechanical installation the following tools
are needed:
•
Drill with 10 or 12 mm drill
•
Tape measure
•
Wrench with relevant metric sockets (7-17 mm)
•
Extensions to wrench
•
Sheet metal punch for conduits or cable glands
in IP 21/Nema 1 and IP 54 units
•
Lifting bar to lift the unit (rod or tube max. Ø 25
mm (1 inch), able to lift minimum 400 kg (880
lbs)).
•
Crane or other lifting aid to place the frequency
converter in position
•
A Torx T50 tool is needed to install the E1 in IP21
and IP54 enclosure types.
7.2.2 General Considerations
Wire access
Ensure that proper cable access is present including
necessary bending allowance. As the IP00 enclosure is
open to the bottom cables must be fixed to the back
panel of the enclosure where the frequency converter is
mounted, i.e. by using cable clamps.
CAUTION
All cable lugs/ shoes must mount within the width of the
terminal bus bar.
Space
Ensure proper space above and below the frequency
converter to allow airflow and cable access. In addition
space in front of the unit must be considered to enable
opening of the door of the panel.
176F
A235.11
<105,0°
526
(20.7)
399
(15.7)
Illustration 7.5 Space in front of IP21/IP54 enclosure type, frame
size D1 and D2 .
Mechanical Installation - ...
FC 300 Design Guide
MG.33.BD.02 - VLT
®
is a registered Danfoss trademark
133
7
7
Содержание VLT AutomationDrive
Страница 1: ...MAKING MODERN LIVING POSSIBLE Design Guide VLT AutomationDrive ...
Страница 280: ...www danfoss com drives MG33BD02 130R0301 MG33BD02 Rev 2011 03 29 ...
Страница 281: ......