FC 302
P900
P1M0
P1M2
High/ Normal load*
HO
NO
HO
NO
HO
NO
Typical shaft output at 550 V [kW]
750
850
850
1000
1000
1100
Typical shaft output at 575 V [HP]
1050
1150
1150
1350
1350
1550
Typical shaft output at 690 V [kW]
900
1000
1000
1200
1200
1400
Enclosure IP21, IP54 without/with
options cabinet
F12/F13
F12/F13
F12/F13
Output current
Continuous (at 550 V) [A]
988
1108
1108
1317
1317
1479
Intermittent (60 s overload) (at 550 V)
[A]
1482
1219
1662
1449
1976
1627
Continuous (at 575/690 V) [A]
945
1060
1060
1260
1260
1415
Intermittent (60 s overload)
(at 575/690 V) [A]
1418
1166
1590
1386
1890
1557
Continuous KVA (at 550 V) [KVA]
941
1056
1056
1255
1255
1409
Continuous KVA (at 575 V) [KVA]
941
1056
1056
1255
1255
1409
Continuous KVA (at 690 V) [KVA]
1129
1267
1267
1506
1506
1691
Maximum input current
Continuous (at 550 V) [A]
962
1079
1079
1282
1282
1440
Continuous (at 575 V) [A]
920
1032
1032
1227
1227
1378
Continuous (at 690 V) [A]
920
1032
1032
1227
1227
1378
Max. cable size, motor [mm
2
(AWG)
1)
]
12x150 (12x300 mcm)
Max. cable size, line power F12
[mm
2
(AWG)
1)
]
8x240 (8x500 mcm)
Max. cable size, line power F13
[mm
2
(AWG)
1)
]
8x400 (8x900 mcm)
Max. cable size, brake [mm
2
(AWG
1)
)]
6x185 (6x350 mcm)
Max. external electrical fuses [A]
2)
1600
2000
2500
Estimated power loss at 600 V [W]
3)
4)
12062
13731
13269
16190
16089
18536
Estimated power loss at 690 V [W]
3) 4)
12524
14250
13801
16821
16719
19247
F3/F4 Max added losses CB or
disconnect & contactor
556
665
634
863
861
1044
Max panel options losses
400
Weight, enclosure IP21, IP 54 [kg]
1261/1562
1295/1596
Weight, rectifier module [kg]
136
136
136
Weight, inverter module [kg]
102
102
136
Efficiency
4)
0.98
Output frequency
0–500 Hz
Power heatsink overtemp. trip
203 °F [95 °C]
221 °F [105 °C]
203 °F [95 °C]
Power card ambient trip
185 °F [85 °C]
* High overload=160% torque during 60 s, Normal overload=110% torque during 60 s.
Table 4.14 Technical Specifications, F12/F13 frames, 525–690 V Line Power Supply 6x525–690 V AC, 12-Pulse
1) American Wire Gauge.
2) For fuse ratings, see chapter 7.2.1 Fuses.
3) Typical power loss is at normal conditions and expected to be within
±
15% (tolerance relates to variety in voltage and cable conditions.) These
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the adjustable frequency drive.
If the switching frequency is raised from nominal, the power losses rise significantly. LCP and typical control card power consumptions are
included. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B
each add only 4 W.
4) Measured using 16.5 ft. [5 m] shielded motor cables at rated load and rated frequency.
Selection
Design Guide
MG34S222
Danfoss A/S © Rev. 2014-02-10 All rights reserved.
77
4
4