Alarm Word Extended Status Word
Bit Hex
Dec
Alarm Word
Alarm Word 2 Warning Word
Warning
Word 2
Extended
Status Word
0
00000001
1
Brake Check
ServiceTrip,
Read/Write
Brake Check
Ramping
1
00000002
2
Pwr. Card Temp ServiceTrip,
(reserved)
Pwr. Card Temp
AMA Running
2
00000004
4
Earth Fault
ServiceTrip,
Typecode/
Sparepart
Earth Fault
Start CW/CCW
3
00000008
8
Ctrl.Card Temp ServiceTrip,
(reserved)
Ctrl.Card Temp
Slow Down
4
00000010
16
Ctrl. Word TO
ServiceTrip,
(reserved)
Ctrl. Word TO
Catch Up
5
00000020
32
Over Current
Over Current
Feedback High
6
00000040
64
Torque Limit
Torque Limit
Feedback Low
7
00000080
128
Motor Th Over
Motor Th Over
Output Current
High
8
00000100
256
Motor ETR Over
Motor ETR Over
Output
Current
Low
9
00000200
512
Inverter Overld.
Inverter Overld.
Output Freq High
10
00000400
1024
DC under Volt
DC under Volt
Output Freq Low
11
00000800
2048
DC over Volt
DC over Volt
Brake Check OK
12
00001000
4096
Short Circuit
DC Voltage Low
Braking Max
13
00002000
8192
Inrush Fault
DC Voltage High
Braking
14
00004000
16384
Mains ph. Loss
Mains ph. Loss
Out of Speed
Range
15
00008000
32768
AMA Not OK
No Motor
OVC Active
16
00010000
65536
Live Zero Error
Live Zero Error
AC Brake
17
00020000
131072
Internal Fault
KTY error
10V Low
KTY Warn Password Time-
lock
18
00040000
262144
Brake Overload Fans error
Brake Overload
Fans
Warn
Password Protec-
tion
19
00080000
524288
U phase Loss
ECB error
Brake Resistor
ECB Warn
20
00100000
1048576
V phase Loss
Brake IGBT
21
00200000
2097152
W phase Loss
Speed Limit
22
00400000
4194304
Fieldbus Fault
Fieldbus Fault
Unused
23
00800000
8388608
24 V Supply Low
24V Supply Low
Unused
24
01000000
16777216
Mains Failure
Mains Failure
Unused
25
02000000
33554432
1.8V Supply
Low
Current Limit
Unused
26
04000000
67108864
Brake Resistor
Low Temp
Unused
27
08000000
134217728 Brake IGBT
Voltage Limit
Unused
28
10000000
268435456 Option Change
Encoder loss
Unused
29
20000000
536870912 Drive Initialized
Output freq. lim.
Unused
30
40000000
1073741824 Safe Stop (A68) PTC 1 Safe
Stop (A71)
Safe Stop (W68)
PTC
1
Safe Stop
(W71)
Unused
31
80000000
2147483648 Mech. brake low Dangerous
Failure (A72)
Extended Status
Word
Unused
Table 6.3: Description of Alarm Word, Warning Word and extended Status Word
The alarm words, warning words and extended status words can be read out via serial bus or
optional fieldbus for diagnose. See also par. 16-90 - 16-94.
WARNING 1, 10 Volts low:
The 10 V voltage from terminal 50 on the con-
trol card is below 10 V.
Remove some of the load from terminal 50, as
the 10 V supply is overloaded. Max. 15 mA or
minimum 590
Ω
.
WARNING/ALARM 2, Live zero error:
The signal on terminal 53 or 54 is less than
50% of the value set in par. 6-10, 6-12, 6-20,
or 6-22 respectively.
WARNING/ALARM 3, No motor:
No motor has been connected to the output of
the frequency converter.
WARNING/ALARM 4, Mains phase loss:
A phase is missing on the supply side, or the
mains voltage imbalance is too high.
This message also appears in case of a fault
in the input rectifier on the frequency convert-
er.
Check the supply voltage and supply currents
to the frequency converter.
WARNING 5, DC link voltage high:
The intermediate circuit voltage (DC) is higher
than the over-voltage limit of the control sys-
tem. The frequency converter is still active.
6. Warnings and Alarms
VLT
®
Automation Drive FC 300
Operating Instructions High Power
126
MG.33.U1.02 - VLT
®
is a registered Danfoss trademark
6