![Danfoss VLT Automation Drive FC 300 Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/danfoss/vlt-automation-drive-fc-300/vlt-automation-drive-fc-300_operating-instructions-manual_3441740089.webp)
Pa
r. No. #
Pa
ra
m
eter descri
pti
on
Defa
ult value
4-
set-
up
FC 3
02
on
ly
Chan
ge duri
ng op-
er
at
io
n
Co
nver-
sion in
dex
Type
6-0*
An
alog I
/O
Mode
6-
00
Li
ve
Z
er
o T
im
eou
t T
im
e
10
s
Al
l set-
ups
TRUE
0
Ui
nt
8
6-
01
Li
ve
Z
er
o T
im
eo
ut F
un
cti
on
[0
] O
ff
Al
l set-ups
TRU
E
-
Ui
nt8
6-1*
An
alog I
n
p
u
t 1
6-
10
Te
rm
in
al
53
L
ow
Vo
lta
ge
0.
07
V
Al
l set-ups
TRU
E
-2
In
t16
6-
11
Te
rmi
nal
5
3 Hi
gh V
oltag
e
10.0
0 V
Al
l se
t-up
s
TR
U
E
-2
In
t1
6
6-
12
Te
rmi
na
l 5
3 Low Curren
t
0.
14
m
A
Al
l set-ups
TRU
E
-5
In
t16
6-
13
Te
rmi
nal
5
3 Hi
gh
Current
20.
00
mA
Al
l se
t-up
s
TR
U
E
-5
In
t1
6
6-
14
Te
rm
in
al
53
L
ow R
ef.
/F
ee
db.
Va
lu
e
0 Re
fere
nceFe
edb
ackUn
it
Al
l set-ups
TRU
E
-3
In
t32
6-
15
Te
rm
in
al
53
H
igh
R
ef.
/F
ee
db.
Va
lu
e
Ex
pr
essi
on
Li
m
it
All
set
-u
ps
TRU
E
-3
In
t32
6-
16
Te
rm
in
al
53
F
ilt
er
Tim
e Con
st
an
t
0.
00
1 s
Al
l set-ups
TRU
E
-3
Ui
nt16
6-2*
An
alog I
n
p
u
t 2
6-
20
Te
rm
in
al
54
L
ow
Vo
lta
ge
0.
07
V
Al
l set-ups
TRU
E
-2
In
t16
6-
21
Te
rmi
nal
5
4 Hi
gh V
oltag
e
10.0
0 V
Al
l se
t-up
s
TR
U
E
-2
In
t1
6
6-
22
Te
rmi
na
l 5
4 Low Curren
t
0.
14
m
A
Al
l set-ups
TRU
E
-5
In
t16
6-
23
Te
rmi
nal
5
4 Hi
gh
Current
20.
00
mA
Al
l se
t-up
s
TR
U
E
-5
In
t1
6
6-
24
Te
rm
in
al
54
L
ow R
ef.
/F
ee
db.
Va
lu
e
0 Re
fere
nceFe
edb
ackUn
it
Al
l set-ups
TRU
E
-3
In
t32
6-
25
Te
rm
in
al
54
H
igh
R
ef.
/F
ee
db.
Va
lu
e
Ex
pr
essi
on
Li
m
it
All
set
-u
ps
TRU
E
-3
In
t32
6-
26
Te
rm
in
al
54
F
ilt
er
Tim
e Con
st
an
t
0.
00
1 s
Al
l set-ups
TRU
E
-3
Ui
nt16
6-3*
An
alog I
n
p
u
t 3
6-
30
Te
rmi
nal
X
30/
11 Lo
w
Vo
ltag
e
0.
07
V
Al
l set-ups
TRU
E
-2
In
t16
6-
31
Te
rmi
nal
X
30/
11 Hi
gh
Vo
ltag
e
10.0
0 V
Al
l se
t-up
s
TR
U
E
-2
In
t1
6
6-
34
Te
rm.
X
30/
11
Lo
w R
ef
./
Fe
ed
b.
Value
0 Re
fere
nceFe
edb
ackUn
it
Al
l set-ups
TRU
E
-3
In
t32
6-
35
Te
rm.
X
30/
11
Hi
gh R
ef
./
Fe
ed
b.
Val
ue
Exp
re
ssionLi
mit
Al
l se
t-up
s
TR
U
E
-3
In
t3
2
6-
36
Te
rm.
X
30/
11 Fi
lter Ti
me
Co
nstant
0.
00
1 s
Al
l set-ups
TRU
E
-3
Ui
nt16
6-4*
An
alog I
n
p
u
t 4
6-
40
Te
rmi
nal
X
30/
12 Lo
w
Vo
ltag
e
0.
07
V
Al
l set-ups
TRU
E
-2
In
t16
6-
41
Te
rmi
nal
X
30/
12 Hi
gh
Vo
ltag
e
10.0
0 V
Al
l se
t-up
s
TR
U
E
-2
In
t1
6
6-
44
Te
rm.
X
30/
12
Lo
w R
ef
./
Fe
ed
b.
Value
0 Re
fere
nceFe
edb
ackUn
it
Al
l set-ups
TRU
E
-3
In
t32
6-
45
Te
rm.
X
30/
12
Hi
gh R
ef
./
Fe
ed
b.
Val
ue
Exp
re
ssionLi
mit
Al
l se
t-up
s
TR
U
E
-3
In
t3
2
6-
46
Te
rm.
X
30/
12 Fi
lter Ti
me
Co
nstant
0.
00
1 s
Al
l set-ups
TRU
E
-3
Ui
nt16
6-5*
An
alog Ou
tp
ut
1
6-
50
Te
rm
in
al
4
2 O
utp
ut
nu
ll
Al
l set-ups
TRU
E
-
Ui
nt8
6-51
Te
rmi
na
l 4
2 Out
put M
in Scal
e
0.
00
%
Al
l set-
ups
TRUE
-2
In
t1
6
6-
52
Te
rmi
nal
4
2 O
utp
ut
M
ax
Sca
le
10
0.0
0 %
Al
l set-ups
TRU
E
-2
In
t16
6-53
Te
rmina
l 4
2 Out
put Bus
Contro
l
0.
00
%
All set-
ups
TRUE
-2
N
2
6-
54
Te
rmi
nal
4
2 O
utp
ut
T
ime
ou
t P
re
set
0.
00
%
1 s
et
-u
p
TRU
E
-2
Ui
nt16
6-6*
An
alog Ou
tp
ut
2
6-
60
Te
rmi
nal
X
30/
8
Output
nu
ll
Al
l set-ups
TRU
E
-
Ui
nt8
6-
61
Te
rmi
nal
X
30/
8
Min.
Scal
e
0.00
%
Al
l se
t-up
s
TR
U
E
-2
In
t1
6
6-
62
Te
rmi
nal
X
30/
8 Max
. S
cal
e
10
0.0
0 %
Al
l set-ups
TRU
E
-2
In
t16
4.3.7.
6-** Analog In/Out
VLT
®
Automation Drive FC 300
Operating Instructions High Power
4. How to Programme
MG.33.U1.02 - VLT
®
is a registered Danfoss trademark
89
4