Pa
r. No. #
Pa
ra
m
eter descri
pti
on
Defa
ult value
4-
set-
up
FC 3
02
on
ly
Chan
ge duri
ng op-
er
at
io
n
Co
nver-
sion in
dex
Type
4-1*
Mot
o
r Limi
ts
4-
10
Mo
tor Spe
ed Direction
nu
ll
Al
l set-ups
FALSE
-
U
in
t8
4-
11
Mo
tor S
pee
d L
ow
Lim
it
[RPM]
Ex
pressio
nLimit
Al
l set-ups
TRU
E
67
Ui
nt16
4-
12
M
ot
or
S
pee
d
Lo
w L
im
it [H
z]
Ex
pr
essi
on
Li
m
it
All
set
-u
ps
TRU
E
-1
U
in
t1
6
4-
13
M
otor S
pee
d H
igh
Li
mi
t
[R
PM
]
Ex
pressio
nLimit
Al
l set-ups
TRU
E
67
Ui
nt16
4-
14
M
otor S
pee
d H
igh
Limit
[
H
z]
Ex
pressi
on
Limi
t
All
set-
ups
TRU
E
-1
U
int1
6
4-
16
To
rque
Li
mi
t
Mo
tor Mode
Ex
pressio
nLimit
Al
l set-ups
TRU
E
-1
Ui
nt16
4-
17
To
rq
ue Lim
it
G
ene
ra
to
r Mo
de
10
0.0
%
Al
l se
t-up
s
TR
U
E
-1
U
in
t16
4-
18
Cu
rrent
Li
mit
Ex
pressio
nLimit
Al
l set-ups
TRU
E
-1
Ui
nt32
4-
19
Ma
x Ou
tput
Fre
que
ncy
132.
0 Hz
Al
l set-ups
FALSE
-1
Ui
nt16
4-2*
Limi
t
Fac
tor
s
4-
20
To
rque
Lim
it F
actor Source
[0
] N
o fu
nc
tio
n
Al
l set-
ups
TRUE
-
Ui
nt
8
4-
21
Sp
eed
Limi
t
Factor Sou
rce
[0
] N
o fu
nc
tio
n
Al
l set-ups
TRU
E
-
Ui
nt8
4-3*
Mot
o
r Fb M
o
n
it
o
r
4-
30
Motor Feedb
ack
Loss Fun
ct
ion
[2] Tri
p
Al
l set-ups
TRU
E
-
Ui
nt8
4-
31
Mo
tor
Fe
ed
back Spee
d E
rror
300
R
PM
All
set-
ups
TRU
E
67
U
int1
6
4-
32
Motor
Feedb
ack Loss Timeout
0.
05 s
Al
l set-ups
TRU
E
-2
Ui
nt16
4-5*
Adj
.
Warn
in
gs
4-
50
W
arning Curren
t
Low
0.
00
A
Al
l set-ups
TRU
E
-2
Ui
nt32
4-
51
Warning
Curre
nt
Hig
h
ImaxV
LT (P
1637
)
Al
l se
t-up
s
TR
U
E
-2
U
in
t32
4-
52
W
arni
ng Spe
ed Lo
w
0 R
PM
Al
l set-ups
TRU
E
67
Ui
nt16
4-
53
Wa
rning
Sp
ee
d Hig
h
outp
ut
Sp
ee
dH
ig
hLim
it
(P4
13)
Al
l se
t-up
s
TR
U
E
67
U
in
t16
4-
54
W
arni
ng Ref
ere
nce Low
-99
9999
.99
9 N/
A
Al
l set-ups
TRU
E
-3
In
t32
4-
55
Warning
R
ef
er
ence
H
ig
h
999
999.
999
N/A
Al
l se
t-up
s
TR
U
E
-3
In
t3
2
4-
56
W
arni
ng F
ee
dbac
k Lo
w
-9999
99.
999 R
ef
er
ence
Fee
db
ackU
ni
t
Al
l set-ups
TRU
E
-3
In
t32
4-
57
Warning
Fe
ed
ba
ck Hig
h
999999
.99
9
R
ef
er
en
ce
Fe
ed
ba
ck
U
nit
Al
l se
t-up
s
TR
U
E
-3
In
t3
2
4-
58
Missi
ng Moto
r Pha
se
Function
[1] On
Al
l set-ups
TRU
E
-
Ui
nt8
4-6*
Spee
d
Bypass
4-
60
By
pass
Spee
d F
ro
m
[
R
PM
]
Ex
pressio
nLimit
Al
l set-ups
TRU
E
67
Ui
nt16
4-
61
By
pass
Spee
d F
ro
m
[
H
z]
Ex
pressi
on
Li
m
it
All
set
-u
ps
TRU
E
-1
U
in
t1
6
4-
62
By
pass Spee
d
To
[
R
PM
]
Ex
pressio
nLimit
Al
l set-ups
TRU
E
67
Ui
nt16
4-
63
By
pass
Spee
d To
[
H
z]
Ex
pressi
on
Li
m
it
All
set
-u
ps
TRU
E
-1
U
in
t1
6
4.3.5.
4-** Limits / Warnings
4. How to Programme
VLT
®
Automation Drive FC 300
Operating Instructions High Power
86
MG.33.U1.02 - VLT
®
is a registered Danfoss trademark
4