background image

For Power Supply Models:

600N, 2200N-A, 2200N-B, 12KN-A, 12KN-B, 12KN -C, 12KN-D

POWER SUPPLY

INSTALLATION & ADJUSTMENT

INSTRUCTIONS

Use Exclusively with FLAT

LITE

® Electroluminescent

Lamps.

! IMPORTANT SAFEGUARDS !

When using electrical equipment, basic safety precautions

 should always be followed including the following:

• This product must be installed and serviced by electrical

contractors familiar with the instructions in this manual and

local building codes.

• FLAT

LITE

® Lamp is an electrical appliance operating at up to

280Vac.

• Do not cut or pierce without proper tools and training.

• Never power the unit from a dimmable AC source.

• Never for use in or under water.

• Never install in an accessible area without a protective cover to

prevent access.

• Do not install against an ungrounded metal surface.

• Always install in accordance with all applicable electrical

codes.

• Always disconnect power from the FLAT

LITE

® system before

servicing.

• Equipment must be mounted securely in locations and at

heights where it will not be readily subjected to tampering by

unauthorized personnel.

• Use of any components not supplied with the FLAT

LITE

®

system or the modification of the components supplied may

cause an unsafe condition.

• Do not use this equipment for other than its intended purpose

• This equipment is approved and rated for connection of lamps

as specified in the system design section. Never exceed the Total

or Minimum Load Rating of any power supply.

SAVE THESE INSTRUCTIONS

MAKING ADJUSTMENTS

Tools Needed:

Phillips head screw driver

Nonconductive blade adjustment tool

Voltmeter capable of reading up to 400VAC RMS

Installed Lamp size (in square inches)

Needle-nose pliers

1. 

Completely disconnect Power Supply from any power source

2

. If any of the optional CMD modules will be used, leave it

disconnected until the Power Supply has been fully adjusted.

3a

. Models 600N, 2200N-A, B: Remove the cover from the Power

Supply and place the supply base so that the components inside

are accessible and the choke(s) are to the right.

3b.

 

Models 12KN-A,B,C and D: Remove the access port cover

from the top of the Power Supply and place the supply so that the

opening is toward you and to the right.

4. 

Confirm that the input voltage select jumper is placed correctly

for your operating voltage 120 or 240VAC (See Figure 1, 2 or 3 for

jumper location). Refer to the marking on the Printed Circuit

Board (PCB).  The jumper tab should connect the front two pins

for 240VAC and the back two pins for 120VAC. (Disregard this

step for Models 12KN-A,B,C,D - voltage adjusts automatically).

5. 

Next, match the Power Supply to the lamp size by connecting

the chokes appropriately (see specifics in Figure 1, 2, or 3.  Note:

2200N-B  requires no choke setup, and chokes on 12KN models

are factory set).

6. 

Locate the output “VOLTAGE ADJ” (white pot) and limit-

adjust  “VOLTAGE LIMITING” (blue pot) potentiometers.  See

Figure 1, 2 or 3 for locations. When adjusting these pots use a

NON CONDUCTIVE TOOL.

7. 

The blue limit pot is preset at the factory and is locked with

glue.  Set up instructions for this blue limit pot are included in

case the glue has been removed or specific instructions to adjust

the pot are given from the factory.  Turn the white pot  all the

way counter clockwise and  the blue limit pot all the way

clockwise.

E-Lite Technologies, Inc. Power Supply Instruction Manual - Page 1 of 4