background image

1

User  Guide

ProJet

®

 

Cart Station

Summary of Contents for ProJet Cart Station

Page 1: ...1 User Guide ProJet Cart Station...

Page 2: ...IMPORTANT SAFETY INFORMATION 5 SPECIFICATIONS and REQUIREMENTS 6 FAMILIARIZATION 7 FACILITY REQUIREMENTS 8 PREPARATION FOR WALL MOUNT 8 9 WALL MOUNT INSTALLATION 10 TABLE MOUNT INSTALLATION 11 OPERATI...

Page 3: ...operating the printer For more detailed material safety information refer to VisiJet Material Handling Guide System Requirements Provides electrical requirements prior to plugging in your printer for...

Page 4: ...talled and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interferen...

Page 5: ...cur at different levels and service providers should only perform tasks they are authorized and certified to complete Disconnect the Umbilical cable before cleaning the cart or material cart Do not re...

Page 6: ...t per Cart Station Noise 65 dB Cart Umbilical Harting 42pin Cart plug 3 foot male Electrical Facility Electrical Requirements 100 240 VAC 50 60 Hz w grounded receptacle Circuit Breaker Amps 5 Amps Pow...

Page 7: ...B A F E F FAMILIARIZATION This Cart Station PN 284107 00 is a wall or table mounted power supply to provide power to the material cart that is sup plied with the ProJet 6000 7000 If the cart is remov...

Page 8: ...0 240 VAC 50 60 Hz w 15 amp grounded receptacle Temperature Ranges Ambient Room Temperature 20 26 degrees C 68 79 degree F Ambient Relative Humidity 20 50 Thumbscrews Using a T 20 torx plus driver rem...

Page 9: ...holes 11 03 280 2 mm 7 48 190 mm Using a 5mm Allen wrench remove the two M6 screws from the bottom left corner of cart Orient holder as shown and align holder holes to the screw holes at the bottom le...

Page 10: ...llips Screwdriver Four 4 6mm or 1 4 screws Anchors anchors depend on the wall type Anchors should be flush to the wall Install station s two upper keyholes backside of station onto the two upper screw...

Page 11: ...that a grounded wall 100 240 VAC 50 60 Hertz 15 amp receptacle is within reach of the power cord Before powering on the station the grounding terminal connection to earth ground should be verified In...

Page 12: ...al connector to the material cart connector It is acceptable to connect the umbilical to the cart when the station is ON Ensure that the print tray is connected to the cart before you start the cart s...

Page 13: ...message will display the cause of the halt on the screen If cart is not connected an Error message will display No Cart detected This system state will not halt the system System Check After the Syst...

Page 14: ...f the pumping routine There is a minimum level required in the cart in order to be able to heat and mix the material Currently this level is just below 1 4 of the cart If the level is more than the mi...

Page 15: ...ply out of range Emergency Stop Button is pressed Material level sensor is disconnected or non operational Material thermistor is disconnected or non operational Heater thermistor is disconnected or n...

Page 16: ...nt and water How ever the station is not water or air tight so care must be taken to ensure no water or other fluids enter through the ventilation holes Any aerosol water or paint sprays should be dir...

Page 17: ...rder Parts New and refurbished parts made by 3D System s manufacturer are used when performing warranty repairs and in building replacement parts and systems Refurbished parts and systems are parts or...

Page 18: ...18 SPARE PARTS VIEW 1 1 2 3 4 No Part Number Description Qty 1 19816 107 00 Scr M6x1 0x20 Soc Ss 2 2 2850 00511 100 Washer M6 2 3 284667 00 Cbl Assy Umbilical 1 4 284668 001 Umbilical Holder 1 1...

Page 19: ...Push button 18mm SPDT Momentary Black 4 5 284661 00 Enclosure Cover 1 6 284670 00 Screen Shield 1 7 284351 00 LCD Kit 4 X 20 Backlit Ribbon Cable 1 8 282949 00 SCR PHPH M2 5 X 8 SS 4 9 284397 00 Loop...

Page 20: ...ircuit Breaker Thermal 2P 240V 5A 1 4 284350 00 5 201989 00 M4 Nut W Tooth 4 6 19816 136 00 Scr M3x 5X8 Soc Ss 10 7 284664 00 Thermal Pad 2 8 284358 00 Interface PCB Assembly 1 9 284663 00 Heatsink PC...

Page 21: ...21 3D Systems Inc 333 Three D Systems Circle Rock Hill SC 29730 www 3dsystems com pn 283455 00 Rev A...

Reviews: