8 How to program the adjustable frequency drive
8.1 How to program
8.1.1 Parameter Set-up
Overview of parameter groups
Group
Title
Function
0-
Operation/Display
Parameters related to the fundamental functions of the adjustable frequency drive, func-
tion of the LCP buttons and configuration of the LCP display.
1-
Load / Motor
Parameter group for motor settings.
2-
Brakes
Parameter group for setting brake features in the adjustable frequency drive.
3-
Reference/Ramps
Parameters for reference handling, defining limitations, and configuring the reaction of
the adjustable frequency drive to changes.
4-
Limits/Warnings
Parameter group for configuring limits and warnings.
5-
Digital In/Out
Parameter group for configuring the digital inputs and outputs.
6-
Analog In/Out
Parameter group for configuring the analog inputs and outputs.
8-
Communication and Options
Parameter group for configuring communications and options.
9-
Profibus
Parameter group for Profibus-specific parameters.
10-
DeviceNet Serial Communication Bus
Parameter group for DeviceNet-specific parameters.
11-
LonWorks
Parameter group for LonWorks parameters
13-
Smart Logic
Parameter group for Smart Logic Control
14-
Special Functions
Parameter group for configuring special adjustable frequency drive functions.
15-
Drive Information
Parameter group containing adjustable frequency drive information such as operating
data, hardware configuration and software versions.
16-
Data Readouts
Parameter group for data readouts, such as current references, voltages, control, alarm,
warning and status words.
18-
Info and Readouts
This parameter group contains the last 10 Preventive Maintenance logs.
20-
Drive Closed-loop
This parameter group is used for configuring the closed-loop PID controller that controls
the output frequency of the unit.
21-
Extended Closed-loop
Parameters for configuring the three extended closed-loop PID controllers.
22-
Application Functions
These parameters monitor water applications.
23-
Time-based Functions
These parameters are for actions to be performed on a daily or weekly basis, such as
different references for working hours/non-working hours.
25-
Basic Cascade Controller Functions
Parameters for configuring the basic cascade controller for sequence control of multiple
pumps.
26-
Analog I/0 Option MCB 109
Parameters for configuring the Analog I/0 Option MCB 109.
27-
Extended Cascade Control
Parameters for configuring the extended cascade control.
29-
Water Application Functions
Parameters for setting water specific functions.
31-
Bypass Option
Parameters for configuring the bypass option
Table 8.1: Parameter Groups
Parameter descriptions and selections are displayed on the Graphic LCP or Numeric LCP in the display area (See Section 5 for details.) Access the
parameters by pressing the [Quick Menu] or [Main Menu] key on the control panel. The quick menu is used primarily for commissioning the unit at start-
up by providing those parameters necessary to commence operations. The main menu provides access to all the parameters for detailed application
programming.
All digital input/output and analog input/output terminals are multifunctional. All terminals have factory default functions suitable for the majority of water
applications but if other special functions are required, they must be programmed in parameter group 5 or 6.
8.1.2 Quick Menu Mode
The GLCP provides access to all parameters listed under the quick menus. To set parameters using the [Quick Menu] button:
Pressing [Quick Menu] the list indicates the different areas contained in the quick menu.
Efficient Parameter Set-up for Water Applications
The parameters can easily be set up for the vast majority of the water and wastewater applications only by using the
[Quick Menu]
.
VLT
®
AQUA Drive
Instruction Manual
8 How to program the adjustable frequency
drive
MG.20.M5.22 - VLT
®
is a registered Danfoss trademark
8-1
8
Содержание vlt aqua
Страница 4: ...Contents VLT AQUA Drive Instruction Manual MG 20 M5 22 VLT is a registered Danfoss trademark...
Страница 12: ...2 Safety VLT AQUA Drive Instruction Manual 2 6 MG 20 M5 22 VLT is a registered Danfoss trademark 2...
Страница 16: ...3 Introduction VLT AQUA Drive Instruction Manual 3 4 MG 20 M5 22 VLT is a registered Danfoss trademark 3...