6.7 Parameters: 8-** Communications and
Options
6.7.1 8-0* General Settings
8-01 Control Site
Option:
Function:
[0]
*
Digital and ctrl.
word
Control by using both digital input
and control word.
[1]
Digital only
Control by using digital inputs only.
[2]
Control word only
Control by using control word only.
The setting in this parameter overrides the settings in
8-50 Coasting Select
to
8-56 Preset Reference Select
.
8-02 Control Word Source
Option:
Function:
[0]
None
[1]
*
FC RS485
[2]
FC USB
8-03 Control Word Timeout Time
Range:
Function:
1 s
*
[ 0.1 -
18000 s]
Enter the maximum time expected to pass
between the reception of two consecutive
telegrams. If this time is exceeded, it indicates
that the telegram communication has stopped.
The function selected in
8-04 Control Word
Timeout Function
is then carried out. A valid
control word triggers the time-out counter.
This parameter specifies which action should be
performed, if a timeout of the control word occurs.
8-04 Control Word Timeout Function
Option:
Function:
[0]
*
Off
[2]
Stop
[5]
Stop and trip
8-06 Reset Control Word Timeout
Option:
Function:
[0]
*
Do not reset
[1]
Do reset
6.7.2 8-1* Control Word Settings
Parameters for configuring the option control word profile.
This parameter selects the interpretation of the control
word and status word. Valid selections are determined by
installed option.
8-10 Control Word Settings
Option:
Function:
[0]
*
FC AFE profile
Bit
AFE Profile
Bit = 0
Bit = 1
0
-
-
1
-
-
2
-
-
3
-
-
4
-
-
5
-
-
6
Stop
Start
7
No Function
Reset
8
-
-
9
-
-
10
Data not valid
Data valid
11
-
-
12
-
-
13
-
-
14
-
-
15
-
-
Table 6.4 Bus Control Word
How to Programme
Operating Instructions
54
Danfoss A/S © Rev. 05/2014 All rights reserved.
MG33X402
6
6