Synchronizing controller
MG.10.N4.02 - VLT is a registered Danfoss trademark
79
775
Synchronous operation, program 2:
Track error (read only).
776
Input status (read only).
Digital control (par. 753 and par. 754): This parameter is showing the actual
status of the 8 digital inputs (I1 - I8) on MK3A as a binary code.
Field bus control (par. 753 and par. 754): This parameter is showing the status
of the field bus control word (PCD 1) as a decimal value.
777
PID-sample time
Factory setting: 1 ms
Setting range: 1 – 1000 ms
User setting: __________ms
The following are display parameters only (read only)
778
Status of Synchronization
The following status flags are defined for position and marker synchronization. The
flags are not updated when using speed synchronization:
Flag: Decimal value Bit
SYNCREADY
1
0
SYNCFAULT
2
1
SYNCACCURACY
4
2
Only marker Synchronization:
Master marker HIT
8
3
Slave marker HIT
16
4
Master marker Error
32
5
Slave marker Error
64
6
The flags are reset when restarting synchronization (SyncStart).
779
Software version number.
This is the software version number of your
synchronizing controller
795
„Slave position“.
The slave position is displayed in quad counts.
796
„Master position“.
The master position is displayed in quad counts.
797
Test run; Program 1:
„Track error“.
The track error is displayed in quad counts.
Synchronous operation; Program 2:
„Sync-error“,
The synchronization error is displayed with the value calculated in
Parameter 747.
798
„Slave speed“.
The slave speed is displayed with the value calculated in
Parameter 745.
799
„Master speed“,
The master speed is displayed with the value calculated in
Parameter 746.