7.3 POWERLINK - Specific Parameter List
Parameter
Default value
Range
Conversion index
Data type
8-01 Control Site
[0] Dig. & ctrl. word
[0-2]
-
Uint8
8-02 Control Word Source
[0] FC RS485
[0-4]
-
Uint8
8-03 Control Word Timeout Time
1
0.1-18000
-1
Uint32
8-04 Control Word Timeout Function
[0] Off
[0-10]
-
Uint8
8-05 End-of-Timeout Function
[0] Hold set-up
[0-1]
-
Uint8
8-06 Reset Control Word Timeout
[0] Do not reset
[0-1]
-
Uint8
8-07 Diagnosis Trigger
[0] Disable
[0-3]
-
Uint8
8-10 Control Word Profile
[0] FC profile
[0-x]
-
Uint8
8-13 Configurable Status Word STW
8-50 Coasting Select
[3] *Logic OR
[0-3]
-
Uint8
8-51 Quick Stop Select
[3] *Logic OR
[0-3]
-
Uint8
8-52 DC Brake Select
[3] *Logic OR
[0-3]
-
Uint8
8-53 Start Select
[3] *Logic OR
[0-3]
-
Uint8
8-54 Reversing Select
[3] *Logic OR
[0-3]
-
Uint8
8-55 Set-up Select
[3] *Logic OR
[0-3]
-
Uint8
8-56 Preset Reference Select
[3] *Logic OR
[0-3]
-
Uint8
8-90 Bus Jog 1 Speed
100 rpm
0-
4-13 Motor Speed
High Limit [RPM]
67
Uint16
8-91 Bus Jog 2 Speed
200 rpm
0-
4-13 Motor Speed
High Limit [RPM]
67
Uint16
12-00 IP Address Assignment
[20] *From node ID
-
-
Unsigned 8
12-01 IP Address
192.168.100.xxx
-
-
Unsigned 32
12-02 Subnet Mask
255.255.255.0
-
-
Unsigned 32
12-03 Default Gateway
0.0.0.0
-
-
Unsigned 32
12-08 Host Name
-
-
String
12-09 Physical Address
00:1B:08:00:00:00
-
-
Visible string 17
12-10 Link Status
[0] No Link
[0-1]
-
Unsigned 8
12-11 Link Duration
00:00:00:00
-
-
Time diff. w/date
12-12 Auto Negotiation
[1] On
[0-1]
-
Unsigned 8
12-13 Link Speed
[0] None
[0-2]
-
Unsigned 8
12-14 Link Duplex
[1] Full Duplex
[0-1]
-
Unsigned 8[
12-20 Control Instance
Application Dependent
0-255
12-21 Process Data Config Write
Application Dependent
12-22 Process Data Config Read
16
1-32
12-23 Process Data Config Write Size
16
1-32
12-24 Process Data Config Read Size
0
0-4294967295
12-28 Store Data Values
12-29 Store Always
[0] Off
12-60 Node ID
[0]
[0-240]
Unsigned 8
12-80 FTP Server
[0] Disable
[0–1]
-
Unsigned 8
12-81 HTTP Server
[0] Disable
[0–1]
-
Unsigned 8
12-82 SMTP Service
[0] Disable
[0–1]
-
Unsigned 8
12-89 Transparent Socket Channel Port
[0] Disable
[0–1]
-
Unsigned 8
12-90 Cable Diagnostic
[0] Disable
[0-1]
-
Unsigned 8
12-91 Auto Cross Over
[0] Enable
[0-1]
-
Unsigned 8
12-93 Cable Error Length
0
0-200
0
Unsigned 16
12-98 Interface Counters
0
0-65535
-
Unsigned 16
12-99 Media Counters
0
0-65535
-
Unsigned 16
16-84 Comm. Option STW
0
0-FFFF
0
V2
16-90 Alarm Word
0
0-FFFF
0
Uint32
Parameters
MCA 123 POWERLINK Operating Instructions
40
MG92C102 - VLT
®
is a registered Danfoss trademark