6.2.21 1F82 NMT_FeatureFlags_U32
Feature flags indicate communication profile specific
properties of the frequency converter.
Bit
Name
Remark
0
Isochronous
1
SDO by UDP/IP
Not supported
2
SDO by ASnd
3
SDO by PDO
Not supported
4
NMT Info Services
Not supported
5
Extended NMT State Commands
Not supported
6
Dynamic PDO Mapping
7
NMT Service by UDP/IP
Not supported
8
Configuration Manager
Not supported
9
Multiplexed Access
10
NodeID setup by SW
Not supported
11
MN Basic Ethernet Mode
Not supported
12
Routing Type 1 Support
Not supported
13
Routing Type 2 Support
Not supported
14
SDO Read/Write All by Index
Not supported
15
SDO Read/Write Multiple Parameter by
Index
Not supported
16..31 Reserved
Table 6.23 Bit Description
6.2.22 1F83h NMT_ EPLVersion_U8
The object holds the POWERLINK communication profile
version that is implemented.
High nibble
Low nibble
POWERLINK Main Version
POWERLINK Sub Version
Table 6.24 Implemented Communication Profile
6.2.23 1F8C NMT_CurrNMTState_U8
This object holds the node‘s current NMT state.
Binary value
NMT state
0001 1100
NMT_CS_NOT_ACTIVE (Default)
0001 1101
NMT_CS_PRE_OPERATIONAL_1
0101 1101
NMT_CS_PRE_OPERATIONAL_2
0110 1101
NMT_CS_READY_TO_OPERATE
1111 1101
NMT_CS_OPERATIONAL
0100 1101
NMT_CS_STOPPED
0001 1110
NMT_CS_BASIC_ETHERNET
Table 6.25 NMS State
6.2.24 1F93h NMT_EPLNodeID_REC
This object contains drives POWERLINK NodeID.
Index, sub-index
Meaning
1F93h 0
Number of entries
1F93h 1
NodeID_U8, [5]
12-68 Cumulative Counters
1F93h 2
NodeIDByHW_BOOL, DIP switch reading
Table 6.26 1F93h NMT_EPLNodeID_REC.
6.2.25 1F98h NMT_CycleTiming_REC
This object contains node-specific timing parameters which
influence the POWERLINK cycle timing.
Index, sub-
index
Meaning
Remark
1F98h 0
Number of entries
1F98h 1
IsochrTxMax-
Payload_U16
Number of transmit bits,
320=10 signals, 32 bit
each
1F98h 2
IsochrRxMax-
Payload_U16
Number of receive bits,
320=10 signals, 32 bit
each
1F98h 3
PResMaxLatency_U32
Latency, fixed to 10 (nS)
1F98h 4
PReqActPayloa-
dLimit_U16
Set by MN during config-
uration
1F98h 5
PResActPayloa-
dLimit_U16
Set by MN during config-
uration
1F98h 6
ASndMaxLatency_U32
Latency, fixed to 10 (nS)
1F98h 7
MultiplCycleCnt_U8
Set by MN during config-
uration
1F98h 8
AsyncMTU_U16
Configurable in the range
of 300 to 1500
Table 6.27 Node-specific Timing Parameters
6.2.26 1F99h
NMT_CNBasicEthernetTimeout_U32
This object specifies the time in
µ
s for which the option
must wait for SoC before switching to basic Ethernet
mode.
Index,
sub-
index
Meaning
Remark
1F99
NMT_CNBasicEthernet-
Timeout_U32
Time in microseconds
before switching to basic
Ethernet mode. Default
5000000 (5 s) Mapped to
12-63 Basic Ethernet Timeout
Table 6.28 Basic Ethernet Timeout
Communication Profile Area
MCA 123 POWERLINK Operating Instructions
MG92C102 - VLT
®
is a registered Danfoss trademark
29