Operating guide | iSave 50 - 70
9
180R9357 | AQ265943679828en-00100
2
IOM iSave 50 - 70 | 0
3
.202
3
3-5 mm
6.
Adjust respectively, verify the measure
ment, and secure both couplings with the
right torques on the locking screws (see
coupling operation & mounting instruc
tion).
7.
Mount the elastic gear ring and mount
the bell housing/iSave on the motor.
After mounting it must be possible to
move the elastic gear ring 3-5 mm (0.12 -
0.2 inch) axial “C”. The check can be done
through the inspection hole of bell
housing. Secure flange bolts with the
right torque.
If alternative mounting is desired, please contact
Danfoss High Pressure Pumps.
Choose proper tolerances to ensure an easy
mounting of the elastic coupling without use of
tools.
Please take care to observe the recommended
length tolerances of the chosen coupling, as an
axial force on the pump will damage the pump.
(“C” can be found on the drawing below).
2
3
1
Thread size
M5
M6
M8
M10
Torque (Nm)
2
4.8
10
17
Details on how to install iSave 50/70 on Danfoss
vertical and horizontal frame can be found in the
Service guide 180R9387.
4.5 Storage
When each iSave is tested before shipment in
demineralized water. When tested the iSave is
emptied and “plugged”, this will prevent frost
damages.
The storage temperature is is:
-40 °C to +70 °C (-40°F to 158 °F) –
provided that the iSave is drained of fluid and
stored “plugged”.
Frost protection is required if the iSave is not
completely drained of fluids at temperatures
below 1 °C .
Storage of iSave that have been in operation:
For shorter periods of storage flush the iSave
with permeate and store.
For long term storage (more than 2 months)
Danfoss recommends servicing the product
and clean any biological growth of the
surfaces. Store the pump dry witout water
inside.
The iSave is NOT delivered frost-protected
from the factory.
Only remove caps from the openings of the
iSave at the time of installation.
For outdoor storage cover the iSave (set) with
waterproof material.
4.6 Outdoor Storage
Danfoss recommends using DOWFROST from
DOW Chemical Company or Chillsafe mono
propylene glycol from Arco Chemical Company.
For further information on anti-freeze media,
please contact Danfoss High Pressure Pumps.
1: Bolts: torque 100 Nm
2: Screw: torque 40 Nm
3: Torque see table below
Содержание iSave 50
Страница 20: ...Operating guide iSave 50 70 20 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Страница 23: ...Data sheet iSave Energy Recovery Device iSave 50 iSave 70 hpp danfoss com...
Страница 45: ...Design guide iSave Energy Recovery Device Start and stop of the SWRO with iSave hpp danfoss com...
Страница 50: ...Danfoss DCS im 2020 01 180R9213 521B1164 DKCFN PI 003 F8 02 50...
Страница 51: ...Design guide Energy Recovery Device iSave Membrane cleaning of RO system hpp danfoss com...
Страница 56: ...Danfoss DCS im 2017 09 521B1165 DKCFN PI 00 G6 02 56...
Страница 57: ...ro solutions com Design Guide APP pumps and iSave overload protection hpp danfoss com...
Страница 65: ...Design Guide APP and iSave overload protection 65 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Страница 66: ...Danfoss DCS im 2018 08 180R9372 521B1412 DKCFN PI 003 O2 02 66...
Страница 74: ...Danfoss DCS im 2019 05 180R9084 521B0540 DKCFN PI 000 D7 02 74...
Страница 75: ...Parts list Energy recovery device iSave 50 70 hpp danfoss com...
Страница 86: ...86 Danfoss DCS im 2021 03 180R9392_AX299849991270en 000701...
Страница 87: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Страница 91: ...91 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...