Instruction | Right and wrong - Hose assembly routing tips
71
180R9357 | AQ265943679828en-00100
2
IOM iSave 50 - 70 | 0
3
.202
3
The use of pipe or fittings between pump
and iSave connectors and hoses should
be avoided. Such configurations can apply
excessive loads on the connectors and can
cause connector and/or connector bolt
failure. If this cannot be avoided, the piping
system must be protected by either hose
whip restraints mounted directly to the
frame or the hard piping must be fixed rela-
tive to any pump/iSave movements.
If hose is bent, ensure max. bending angle
and distance S from each connector (see
table 1 on page 5).
WRONG
RIGHT
To prevent hose collapse and flow restriction,
hose bend radii should be kept as large as
possible. Tight bends can also compromise
the hose reinforcement and cause premature
hose failure. Refer to hose specification table
on page 6 for minimum bend radii.
WRONG
HIGH
PRESSURE
NO
PRESSURE
To allow the hose to expand when
pressurized, clamps should not be used at
bends. If possible, do not clamp high and
low pressure lines together.
RIGHT
MAX.
BENDING
ANGLE
WRONG
RIGHT
The hose must have a distance S before
bending starts.
NO
PRESSURE
HIGH
PRESSURE
Содержание iSave 50
Страница 20: ...Operating guide iSave 50 70 20 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Страница 23: ...Data sheet iSave Energy Recovery Device iSave 50 iSave 70 hpp danfoss com...
Страница 45: ...Design guide iSave Energy Recovery Device Start and stop of the SWRO with iSave hpp danfoss com...
Страница 50: ...Danfoss DCS im 2020 01 180R9213 521B1164 DKCFN PI 003 F8 02 50...
Страница 51: ...Design guide Energy Recovery Device iSave Membrane cleaning of RO system hpp danfoss com...
Страница 56: ...Danfoss DCS im 2017 09 521B1165 DKCFN PI 00 G6 02 56...
Страница 57: ...ro solutions com Design Guide APP pumps and iSave overload protection hpp danfoss com...
Страница 65: ...Design Guide APP and iSave overload protection 65 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Страница 66: ...Danfoss DCS im 2018 08 180R9372 521B1412 DKCFN PI 003 O2 02 66...
Страница 74: ...Danfoss DCS im 2019 05 180R9084 521B0540 DKCFN PI 000 D7 02 74...
Страница 75: ...Parts list Energy recovery device iSave 50 70 hpp danfoss com...
Страница 86: ...86 Danfoss DCS im 2021 03 180R9392_AX299849991270en 000701...
Страница 87: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Страница 91: ...91 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...